background image

w w w. t r i o n i n c . c o m

707-U

Atomizing Humidifier

©2008 Trion

®

- Indoor Air Quality Solutions | Herrmidifier

®

 - Engineered Humidification Solutions Trion

® 

 and Herrmidifier

® 

 are registered trademarks 

of Air System Components, Inc. Trion

®

 reserves the right to revise or modify products and/or specifications without notice

All product specifications reflect available information at the printing of this brochure. 

Trion

®

 | 101 McNeill Road | Sanford, NC 27330 | Phone: 800-884-0002 | Fax: 800-458-2379

Web: www.trioninc.com | Email: customerservice@trioninc.com

H-707U-1008

T E C H N I C A L     E N G I N E E R I N G     S P E C I F I C A T I O N

A i r   P u r i f i c a t i o n   S y s t e m s

Evaporator Supply Capacity

Humidifier Capacity Selection Guide

Furnace Temp.

707-U

°F 

°C

Gallons per Day Liters per Hour

100°F

37.7°C

6.0

0.95

120°F 

48.8°C 

6.0

0.95

140°F 

60°C 

6.0

0.95

Model

707-U

Part No. 

356686-001 

Type Of Unit 

Centrifugal Atomizer 

Max Evaporative Capacity 

6.0 Gallons Per Day - (0.95 Lph) 

Voltage 

120 V 

Unit Weight 

11 Lbs (5.0 Kg) 

Shipping Weight 

13 Lbs (5.9 Kg) 

Dimensions 

10 1/2" Diameter x 12" H / Packaging - 13 1/4" W x 13 1/4" D x 16 3/4" H 

(276 mm x 305 mm) / (Packaging - 336 W x 336 D X 425 H mm) 

Water Supply 

1/4" (6.4 mm) Copper or Plastic, 125 PSI (8.6 Bar), Not Included 

Drain 

1/2 " (13 mm) 

Humidistat 

Adjustable from 20% to 80% Relative Humidity 

Drain

 

1/2” (12.8 mm) O.D. 

707-U

Sq. Footage (m) of Home

 

Tight

1

 House

Average

2

 House

Loose

3

 House

1000 

(92.9 m

2

)

0.5 

(0.08)

5.0 

(0.8)

10.0 

(1.6)

1500 

(139.4 m

2

)

3.0 

(0.5)

10.0 

(1.6)

16.5

(2.6)

2000 

(185.8 m

2

)

5.0 

(0.8)

14.0 

(2.2)

24.0 

(3.8)

2500 

(232.3 m

2

)

7.5 

(1.2)

19.0 

(3.0)

30.5 

(4.8)

3000 

(278.7 m

2

)

10.0 

(1.6)

23.5 

(3.7)

37.5 

(5.9)

3500 

(325.2 m

2

)

14.5 

(2.3)

33.0 

(5.2)

51.5 

(8.1)

1.

 A “Tight Home” is assumed to be well insulated with vapor barriers, tight storm windows and doors, and a dampered fireplace. Air exchange rate of .5 changes per hour.

2.

 An “Average Home” is insulated and has a dampered fire place, but there are no vapor barriers, storm doors, or storm windows. Air exchange rate of 1.0 change per hour.

3.

 A “Loose Home” is generally one constructed before 1930, has little or no insulation, no storm doors, storm windows, weather stripping or vapor barriers, and often no 

effective dampering of fireplaces. Air exchange rate is as high as 1.5 changes per hour.

Cold Air Return Duct

Discharge
Dome

Wire Mounting

Bracket

Extension

Nozzle

Discharge 

Extension

Nozzle

Outside 

Wall

Inside Wall

Installation Options

Reviews: