background image

Comfort

BREEZE™

 Model CB777

I n s t a l l a t i o n ,   O p e r a t i o n ,   &   M a i n t e n a n c e   M a n u a l

3

www.trioniaq.com

1. Warranty

Humidifier 2-Year Limited Warranty

This  limited  warranty  covers  TRION  Residential  Type  Humidifiers, 

excluding duct work, wiring and installation. TRION warrants that all new 

TRION  humidifiers  are  free  from  defects  in  material  and  workmanship 

under normal, non-commercial use and service. TRION will remedy any 

covered defects if they appear within 24 months from the date of original 

installation  &  subject  to  the  terms  and  conditions  of  this  Limited  2-Year 

Warranty stated below:

1. 

THIS LIMITED 2-YEAR WARRANTY is granted by TRION Customer 

Service, 101 McNeill Road, Sanford, NC 27330.

2. 

This warranty shall extend only to any non-commercial owner who 

has purchased the residential humidifier other than for purposes of 

resale.

3.  All components are covered by this limited warranty except 

expendable items, such as evaporative pads, media filter pads and 

nozzles.

4. 

If, within the warranty period, any TRION residential humidifier unit 

or component requires service it must be performed by a competent 

heating and/or air conditioning contractor (preferably the installing 

contractor). TRION will not pay shipping charges, or labor charges 

to remove or replace such defective parts or components. If the 

part or component is found by inspection to contain such defective 

material and workmanship it will be either repaired or exchanged free 

of charge at TRION’s option, and returned freight collect.

5. 

In order to obtain the benefits of this limited 2-year warranty, the owner 

must notify the dealer or distributor of any defect within 30 days of its 

discovery. If after reasonable time you have not received an adequate 

response  from  the  dealer  or  distributor,  notify  in  writing  to  TRION 

Customer  Service  101  McNeill  Road,  Sanford,  NC  27330,  or  call 

1-800-884-0002 or email customerservice@trioniaq.com Humidifiers 

which have been installed or become part of real estate cannot be 

returned. TRION will receive, freight prepaid, only removable parts or 

components of such defective humidifiers.

6.  This limited warranty does not apply to any part or component that is 

damaged in transit or in handling, has been subject to misuse, neglect 

or accident; has not been installed, operated and serviced according 

to TRION’s instructions; has been operated beyond the factory rated 

capacity; or altered in any such way that its performance is affected. 

There is no warranty due to neglect, alteration or ordinary wear and 

tear. TRION’s liability is limited to replacement of defective parts or 

components and does not include the payment of the cost of labor 

charges to remove or replace such defective components or parts.

7.  TRION will not be responsible for loss of use of any product; loss of 

time, inconvenience, or any other indirect, incidental or consequential 

damages  with  respect  to  person  or  property,  whether  as  a  result 

of  breach  of  warranty,  neglect  or  otherwise.  SOME  STATES  DO 

NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL 

OR  CONSEQUENTIAL  DAMAGES,  SO  THE  LIMITATION  OR 

EXCLUSION  IN THE  PRECEDING  SENTENCE  MAY  NOT APPLY 

TO YOU. 

8. 

THIS WARRANTY GIVES YOU SPECIFIC RIGHTS, AND YOU MAY 

ALSO  HAVE  OTHER  RIGHTS  WHICH  VARY  FROM  STATE  TO 

STATE.

9. 

Any warranty by TRION of merchantability, fitness for use or any other 

warranty (express, implied or statutory), representation or guarantee 

other than those set forth herein, shall expire at the expiration date 

of this express limited warranty. SOME STATES DO NOT ALLOW 

LIMITATIONS  ON  HOW  LONG AN  IMPLIED  WARRANTY  LASTS, 

SO THE LIMITATION IN THE PRECEDING SENTENCE MAY NOT 

APPLY TO YOU.

10. 

TRION reserves the right to make changes in the design and material 

of its products without incurring any obligation to incorporate such 

changes in units completed on the effective date of such change.

WARNING: Failure to install an air flow proving switch may result 

in moisture build-up inside of the ductwork.  Leaks, mold growth, 

and severe water damage may result.

CAUTION

Trion  recommends  that  this  humidifier  be  installed  by  a 

trained HVAC professional.  Do not connect the unit to the 

power source until the installation is complete.  A thorough 

checkout of the unit installation should be completed before 

operating the unit.  Failure to follow these directions may void 

the manufacturer’s original warranty.

2. Safety & Warnings

DANGER

RISK OF ELECTRIC SHOCK

Before cleaning, servicing, or parts replacement, the unit must 

be disconnected from all sources of electricity.

CAUTION

Read these instructions thoroughly before installing this unit.  

Check  data  label  and  verify  electrical  specifications  agree 

with those at the point of installation.

WARNING

Improper  installation,  adjustment,  alteration,  service,  or 
maintenance may cause property damage, injury, or death.  This 

appliance must be installed according to these instructions.  Read 
these instructions thoroughly before installing or servicing the unit.

WARNING

Failure to install this unit in a position that is level and plumb 

may impair the unit’s ability to drain if an overflow condition 

presents itself.  Damage to personal property may also result.

WARNING

Installation in freezing conditions can result in unit failure. 
Damage to personal property may also result.  

WARNING

This appliance is not intended for use by children or persons 

with reduced physical, sensory or mental capabilities, or lack 
of experience and knowledge, unless they have been given 

supervision or instruction concerning use of the appliance 
by a person responsible for their safety.  Children should be 
supervised to ensure that they do not play with the appliance.

WARNING

A drain pan should be installed under the unit and any supply 
water / drain connections to prevent damage to property in the 
event of a water leak or faulty operation.

CAUTION

TRION  recommends  that  this  humidifier  be  installed  by  a 

trained HVAC professional.  Do not connect the unit to the 
power source until the installation is complete.  A thorough 
checkout of the unit installation should be completed before 
operating the unit.  Failure to follow these directions may void 
the manufacturer’s original warranty.

Summary of Contents for CB777

Page 1: ...T R I O N w w w t r i o n i a q c o m CB777 Centrifugal Atomizing Humidifier READ AND SAVE THESE INSTRUCTIONS UNIT NOT FOR COMMERCIAL USE...

Page 2: ...INSTRUCTIONS TABLE OF CONTENTS 1 Warranty Statement 3 2 Safety Warnings 3 3 Introduction 4 3 1 Unit Specifications 4 3 2 Capacity Selection Guide 4 3 3 Operation 4 4 Installation 5 4 1 Selecting the U...

Page 3: ...e SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE LIMITATION OR EXCLUSION IN THE PRECEDING SENTENCE MAY NOT APPLY TO YOU 8 THIS WARRANTY GIVES YOU SP...

Page 4: ...t Side Mount Free Standing Wall Mounts on face of vertical or side of horizontal return duct Includes independent mounting bracket Mounts on wall Includes independent mounting bracket 3 2 Capacity Sel...

Page 5: ...izontal return duct or on the face of a vertical return duct certain conditions must be met for its proper operation Mount the humidifier on the vertical or horizontal cold air return duct Locate the...

Page 6: ...mproper electrical wiring can cause personal shock injury or property damage It is required that the unit be installed by a properly qualified HVAC technician or electrician following NEC and any othe...

Page 7: ...can be used to combat algae build up should it become evident At the end of the winter humidification season drain and thoroughly clean your humidifier as part of the summer shutdown Like your heating...

Page 8: ...Brass 4 5 19 Retainer Clip 1 6 352728 001C Motor Base 1 7 45C Diffuser Screen 1 8 D9PC Impeller 1 9 6 32 Set Screw 6 32 x 5 16 1 10 8AC Pump 4 11 90 Bushing 1 12 35PC Center Pan 4 13 23C Center Pan Su...

Reviews: