I n s t a l l a t i o n ,   O p e r a t i o n ,   &   M a i n t e n a n c e   M a n u a l

7

www.trioniaq.com

Humidistat Installation

Humidistat:

1.  Locate the humidistat in the living area making sure that it 

is at least five (5) feet from a supply register (duct mounted 

installation) or discharge nozzle (free standing installation).

2.  The humidistat should be installed four and a half (4 1/2) 

feet above the floor, out of the direct sun and not subject to 

damage from traffic within the room.

3.  If you would like the ability to cut off the electricity to the 

humidifier for maintenance, a throw -switch may be installed.

4. 

Turn the humidistat to the highest level (past 60%) and the 

humidifier should begin to run. The humidifier should stop 

when the humidistat is turned off.

5.  Set the furnace controls and humidistat for the desired 

conditions (30-40% RH is recommended). Operation of this 

unit is automatic.

6. 

If condensation occurs on single pane windows, lower the 

humidistat setting until the condensation has disappeared.

NOTE:  It  may  take  several  days  for  the  humidity  level  in 

your home to reach comfortable levels.

5. Maintenance

Caution:

Before cleaning or servicing this unit, it is recommended 

that the unit be disconnected from any electrical supply 

outlet.

To  enjoy  the  benefits  of  a  properly  humidified  environment, 

periodic cleaning is necessary to control both water and 

household impurities. Film or scum, which can contain bacteria

or fungi, may appear on the water surface, the sides, or bottom 

of  your  humidifier. A  crusty  deposit  or  scale  may  also  appear 

and is composed of minerals that have settled out of the water. 

To improve the efficiency of your humidifier, and to reduce the 

possibility of a health hazard, it is recommended that you take 

the following precautions:

• 

Follow the manufacturer’s recommended cleaning and 

maintenance instructions below and on the next page.

• 

The amount of minerals and other impurities in a water 

source can vary greatly, therefore, the frequency of cleaning 

the unit also varies.

• 

During the heating season, check for film or scale build-up 

in the unit, or any moving part. Establish a proper cleaning 

schedule to ensure the efficiency of the humidifier.

• 

An  algaecide,  such  as  a  humidifier  cleaning  tablet  or 

bacteriostatic liquid/powder, can be used to combat algae 

build-up, should it become evident.

• 

At the end of the winter humidification season, drain and 

thoroughly  clean  your  humidifier  as  part  of  the  summer 

shutdown. Like your heating system and air conditioning 

unit,  periodic  maintenance  and  cleaning  are  required  to 

ensure the safe and efficient operation of your humidifier. 

Due to the operation cycle of the furnace and humidifier, it 

may require 2 to 5 days to reach the proper humidification 

level.

Maintenance instructions for models mounted on the face 

of a vertical return duct, side of a horizontal return duct, or 

mounted behind a wall using discharge extension. 

Your humidifier is constructed from quality materials to assure 

superior performance during normal operation. The motor 

bearings are permanently lubricated and do not require oiling. 

The motor is also thermal overload protected against extreme 

conditions.

To clean the unit:

1.  Turn the power to the furnace OFF or turn off the electric 

switch to the humidifier, if provided.

2. 

Disconnect the humidifier motor leads.

3. 

Turn off the humidifier water supply from the saddle valve 

and remove water line from humidifier.

4. 

Remove the humidifier from the wire mounting bracket.

5. 

Remove the discharge dome from the humidifier by pressing 

on the sides of the dome and lifting upward.

6.  Lift the entire atomizing assembly from the water reservoir 

pan.

7.  Remove the pump from the end of the impeller shaft. If the 

pump is stuck in the motor drive shaft, run hot water over 

the end of the shaft for a few seconds to loosen the pump.

8. 

Flush water through the impeller tube, ensuring that the six 

holes at the top of the impeller tube are open and clear of 

mineral deposits. A pipe cleaner works well for this cleaning 

operation. Note: The impeller tube and pump can become 

clogged by algae formations prevalent in certain water 

sources. The  addition  of  10  drops  of  bleach  to  the  water 

reservoir pan each week is advisable.

9.  Replace the pump into the impeller shaft.

10. 

Carefully rotate the impeller to ensure it turns freely. Do not 

force the impeller shaft to turn or breakage could result.

11. 

With  the  atomizing  assembly  removed,  clean  the  water  

reservoir pan thoroughly. We suggest either a water/white 

vinegar solution or liquid humidifier cleaner.

12. 

Reassemble and remount the humidifier by reversing steps 

6, 5, and 4.

13. 

Reconnect the water line and motor leads to the humidifier, 

turn on the water supply from the saddle valve and restore 

electrical power.

Summary of Contents for CB777

Page 1: ...T R I O N w w w t r i o n i a q c o m CB777 Centrifugal Atomizing Humidifier READ AND SAVE THESE INSTRUCTIONS UNIT NOT FOR COMMERCIAL USE...

Page 2: ...INSTRUCTIONS TABLE OF CONTENTS 1 Warranty Statement 3 2 Safety Warnings 3 3 Introduction 4 3 1 Unit Specifications 4 3 2 Capacity Selection Guide 4 3 3 Operation 4 4 Installation 5 4 1 Selecting the U...

Page 3: ...e SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE LIMITATION OR EXCLUSION IN THE PRECEDING SENTENCE MAY NOT APPLY TO YOU 8 THIS WARRANTY GIVES YOU SP...

Page 4: ...t Side Mount Free Standing Wall Mounts on face of vertical or side of horizontal return duct Includes independent mounting bracket Mounts on wall Includes independent mounting bracket 3 2 Capacity Sel...

Page 5: ...izontal return duct or on the face of a vertical return duct certain conditions must be met for its proper operation Mount the humidifier on the vertical or horizontal cold air return duct Locate the...

Page 6: ...mproper electrical wiring can cause personal shock injury or property damage It is required that the unit be installed by a properly qualified HVAC technician or electrician following NEC and any othe...

Page 7: ...can be used to combat algae build up should it become evident At the end of the winter humidification season drain and thoroughly clean your humidifier as part of the summer shutdown Like your heating...

Page 8: ...Brass 4 5 19 Retainer Clip 1 6 352728 001C Motor Base 1 7 45C Diffuser Screen 1 8 D9PC Impeller 1 9 6 32 Set Screw 6 32 x 5 16 1 10 8AC Pump 4 11 90 Bushing 1 12 35PC Center Pan 4 13 23C Center Pan Su...

Reviews: