background image

Form No. 269451-001  Rev. 07/17

©  TRION 2017.  All Rights Reserved.

TRION

®

101 McNeill Rd.  |  Sanford, NC 27330

P: 800.884.0002  |  F: 800.458.2379  |  www.trioniaq.com  |  customerservice@trioniaq.com

6. Parts List and Unit Diagram

Model 269450-001 Model CB777

Qty

Item Part No

Description

1

1

40

Discharge Dome

1

2

252413-001C

Motor Cover

1

3

252596-001C

Motor

6

4

10-32

Nut #10-32, Brass

4

5

19

Retainer Clip

1

6

352728-001C

Motor Base

1

7

45C

Diffuser Screen

1

8

D9PC

Impeller

1

9

6-32

Set Screw #6-32 x 5/16

1

10

8AC

Pump

4

11

90

Bushing

1

12

35PC

Center Pan

4

13

23C

Center Pan Support

1

14

16

Grommet

1

15

92PC

Float & Valve Assembly

1

16

47-BC

Bottom Pan

1

17

269529-001

Logo Label

1

18

FV-10

Locknut

1

19

FV-11

Sleeve, Brass, 1/4” Com. (Ferrule)

1

20

FV-12

Nut, Brass, 1/4” Com.

1

21

352680-002C

Humidistat (Not Shown)

I n s t a l l a t i o n ,   O p e r a t i o n ,   &   M a i n t e n a n c e   M a n u a l

1

2

3

5

4

6

7

8

9

10

11

12

13

14

15

16

17

18 19

20

Summary of Contents for CB777

Page 1: ...T R I O N w w w t r i o n i a q c o m CB777 Centrifugal Atomizing Humidifier READ AND SAVE THESE INSTRUCTIONS UNIT NOT FOR COMMERCIAL USE...

Page 2: ...INSTRUCTIONS TABLE OF CONTENTS 1 Warranty Statement 3 2 Safety Warnings 3 3 Introduction 4 3 1 Unit Specifications 4 3 2 Capacity Selection Guide 4 3 3 Operation 4 4 Installation 5 4 1 Selecting the U...

Page 3: ...e SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE LIMITATION OR EXCLUSION IN THE PRECEDING SENTENCE MAY NOT APPLY TO YOU 8 THIS WARRANTY GIVES YOU SP...

Page 4: ...t Side Mount Free Standing Wall Mounts on face of vertical or side of horizontal return duct Includes independent mounting bracket Mounts on wall Includes independent mounting bracket 3 2 Capacity Sel...

Page 5: ...izontal return duct or on the face of a vertical return duct certain conditions must be met for its proper operation Mount the humidifier on the vertical or horizontal cold air return duct Locate the...

Page 6: ...mproper electrical wiring can cause personal shock injury or property damage It is required that the unit be installed by a properly qualified HVAC technician or electrician following NEC and any othe...

Page 7: ...can be used to combat algae build up should it become evident At the end of the winter humidification season drain and thoroughly clean your humidifier as part of the summer shutdown Like your heating...

Page 8: ...Brass 4 5 19 Retainer Clip 1 6 352728 001C Motor Base 1 7 45C Diffuser Screen 1 8 D9PC Impeller 1 9 6 32 Set Screw 6 32 x 5 16 1 10 8AC Pump 4 11 90 Bushing 1 12 35PC Center Pan 4 13 23C Center Pan Su...

Reviews: