I. WARRANTY

Limited 2-Year Warranty

Seller warrants the equipment of its manufacturing to be free 

from defects in workmanship and material for a period of 24 

months after shipment or 24 months after initial commissioning, 

whichever occurs first. This warranty is limited, however, to the 

repair or replacement of defective equipment, which is returned, 

freight prepaid, to Seller’s factory. 

This limited warranty does not apply to any part or component 

that is damaged in transit or when handling, has been subject 

to misuse, negligence or accident, has not been installed, oper-

ated or serviced according to Seller’s instructions, or has been 

operated beyond the factory-rated capacity or has been altered 

in any way.

Seller’s liability is limited to replacement of defective parts or 

components and does not include any cost of labor (including, 

but not limited to, labor required to remove and/or reinstall any 

defective part) other than TRION/HERRMIDIFIER factory labor. 

TRION/HERRMIDIFIER shall not be responsible for loss of use 

of any product, loss of time, inconvenience, or damage to other 

equipment, or any other indirect or consequential damage with 

respect to property whether as a result of breach of warranty, 

neglect, or otherwise. 

THE WARRANTIES AND LIABILITIES SET FORTH ARE IN 

LIEU OF ALL OTHER WARRANTIES AND LIABILITIES, EX-

PRESSED OR IMPLIED, IN LAW OR IN FACT, INCLUDING IM-

PLIED WARRANTIES OF MERCHANTABILITY AND FITNESS 

FOR PARTICULAR PURPOSE. 

The foregoing shall constitute the total liability of seller in the 

case of defective performance of all or any of the equipment or 

services provided to Buyer. Buyer agrees to accept and hereby 

accepts the foregoing as the sole and exclusive remedy for any 

breach or alleged breach of warranty by Seller. 

II. GENERAL WARNINGS & INSTALLER RESPONSIBILITY

WARNING

INSTALL, OPERATE, AND MAINTAIN UNIT IN ACCORDANCE 

WITH MANUFACTURER’S INSTRUCTIONS TO AVOID ANY 

CIRCUMSTANCES THAT MAY CAUSE PERSONAL INJURY 

OR PROPERTY DAMAGE.

WARNING

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, 

SERVICE, OR MAINTENANCE CAN CAUSE PROPERTY 

DAMAGE, INJURY, OR DEATH. THIS APPLIANCE MUST BE 

INSTALLED BY A LICENSED CONTRACTOR OR QUALIFIED 

SERVICE PERSONNEL. READ THESE INSTALLATION, 

OPERATING, AND MAINTENANCE INSTRUCTIONS 

THOROUGHLY BEFORE INSTALLING OR SERVICING THE UNIT.

DANGER OF BURNS

THE HUMIDIFIER CONTAINS HIGH TEMPERATURE 

COMPONENTS AND DELIVERS STEAM AT 100°C/212°F.

ATTENTION

READ THIS MANUAL, FACTORY INSTALLED OPTIONS 

MANUAL, UNIT SUBMITTAL DATA SHEETS AND ALL 

LABELS ATTACHED TO THE UNIT CAREFULLY BEFORE 

ATTEMPTING TO INSTALL, OPERATE, OR SERVICE 

THESE UNITS. CHECK DATA PLATES FOR ELECTRICAL 

SPECIFICATIONS AND MAKE CERTAIN THAT THESE 

AGREE WITH THOSE AT THE POINT OF INSTALLATION.

DANGER OF ELECTRIC SHOCK

INSTALL, OPERATE AND MAINTAIN UNIT IN ACCORDANCE 

WITH MANUFACTURER’S INSTRUCTIONS TO AVOID ANY 

CIRCUMSTANCES THAT MAY CAUSE PERSONAL INJURY 

OR PROPERTY DAMAGE.

DANGER OF WATER LEAKS

THE HUMIDIFIER AUTOMATICALLY AND CONSTANTLY 

FILLS/DRAINS CERTAIN QUANTITIES OF WATER. 

MALFUNCTIONS IN THE CONNECTIONS OR IN THE 

HUMIDIFIER MAY CAUSE LEAKS. A DRAIN PAN IS 

RECOMMENDED UNDER THE UNIT TO PROTECT 

PROPERTY FROM DAMAGE IN THE CASE OF WATER 

LEAKAGE OR SPILLAGE.

Important

• 

The installation of the product must include an earth 

connection.

• 

The environmental and power supply conditions must 

conform to the values specified on the product rating labels.

• 

The product is designed exclusively to humidify rooms 

either directly or through distribution systems (ducts).

• 

Only qualified personnel who are aware of the necessary 

precautions and able to perform the required operations 

correctly may install, operate, or carry out technical service 

on the product.

• 

Only water with the characteristics indicated in this manual 

must be used for steam production.

• 

All operations on the product must be carried out according 

to the instructions provided in this manual and on the labels 

applied to the product. Any uses or modifications that are not 

authorized by the manufacturer are considered improper. 

Seller declines all liability for any such unauthorized use.

• 

Do not attempt to open the humidifier in ways other than 

those specified in the manual.

• 

Observe the standards in force in the place where the 

humidifier is installed.

• 

Keep the humidifier out of the reach of children and animals.

• 

Do not install and use the product near objects that may 

be damaged when in contact with water (or condensate). 

Seller declines all liability for direct or indirect damage 

following water leaks from the humidifier.

• 

Do not use corrosive chemicals, solvents, or aggressive 

detergents to clean the inside and outside parts of the 

humidifier, unless specifically indicated in the user manual.

• 

Do not drop, hit, or shake the humidifier, as the inside parts 

and the linings may be irreparably damaged.

Summary of Contents for HERRMIDIFIER Herrmidicool

Page 1: ...T R I O N w w w t r i o n i a q c o m Herrmidicool Installation Operation Maintenance READ SAVE THESE INSTRUCTIONS...

Page 2: ...ion 4 II Operational Characteristics 4 III Mounting 4 IV Plumbing 4 V Controls 5 VI Control Board Operation 5 VII Start up Checklist 6 VIII Start up 7 IX Atomizing Head Operation 7 X Pressure Settings...

Page 3: ...OROUGHLY BEFORE INSTALLING OR SERVICING THE UNIT DANGER OF BURNS THE HUMIDIFIER CONTAINS HIGH TEMPERATURE COMPONENTS AND DELIVERS STEAM AT 100 C 212 F ATTENTION READ THIS MANUAL FACTORY INSTALLED OPTI...

Page 4: ...ata prior to selecting equipment NOTE If units are mounted in outdoor enclosures conditions inside enclosure must be maintained as listed above III MOUNTING The Herrmidicool system consists of two bas...

Page 5: ...as inside of comers Air proving devices should be mounted so that they sense airflow or the absence of it Wire the device so that it closes when airflow is present and will open when there is no airfl...

Page 6: ...GING SOME OF THESE SETTINGS MAY RENDER THE FACTORY WARRANTY VOID When touching SETUP or MODULE STATUS the administrator will be prompted for a password Enter 2222 to log in to the controller Network s...

Page 7: ...settings at any other time The instructions below assume that the atomizing heads are installed at the same elevation as the water control section Adjustment from this standard must be made to compens...

Page 8: ...reign matter may be restricting water flow in the water nozzle AH 942 Turn off the air and water valves at the head Remove the atomizer nozzle and water nozzle Blow water nozzle with air Do not use wi...

Page 9: ...Spring Nut 253208 002 Spring Nut AH 12 R Valve Stem w Needle AH 12 R SS Valve Stem w Needle AH 19A Air Port AH 19ASS Air Port AH 18A Union Tail Piece AH 18ASS Union Tail Piece AH 20 Union Nut AH 20SS...

Page 10: ...i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 10 www trioniaq com XVI WIRING DIAGRAM WARNING Absolutely no other components may be mounted inside or electrically tapped into the humidifie...

Page 11: ...Herrmidicool I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 11 www trioniaq com THIS PAGE INTENTIONALLY LEFT BLANK...

Page 12: ...2018 TRION All Rights Reserved TRION 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com Form No 269604 001 Rev 06 18...

Reviews: