D01-903en201912 Manual Dissolved Oxygen

General Information 

//

  Dissolved Oxygen

Us

e

Us

e

Calibr

ation

Calibr
ation

M

alfunc

tion &

M

ain

tenanc

e

M

alfunc

tion &

 M

ain
tenanc

e

Commissioning

Commissioning

In

tr

oduc

tion

In

tr

oduc

tion

G

ener

al 

Inf

or

ma

tion

G

ener

al 

Inf

or

ma
tion

FA

Q

FA

Q

Technical 

Da

ta

Technical 

Da

ta

W

ar

ran

ty

W

ar

ran

ty

Cust

omer 

Ser

vic

e

Cust
omer

Ser

vic

e

Con

tac

t

Con

tac
t

Key

w

or

d I

nde

x

Key
w

or

d I

nde
x

Ac

cessor

ies

Ac

cessor

ies

1 General Information

1.1 Introduction

Welcome to TriOS.

We are glad that you have chosen to purchase the Dissolved Oxygen sensor. 

The Dissolved Oxygen sensor is based on luminescent optical technology. With only low calibration requirements and thanks 
to an ultra low power technology, the sensor meets the demands of field works and short or long term campaigns. Without 
oxygen consumption, this technology allows you an accurate measure in all situations and especially in very low oxygen con-
centrations. The “smart” Oxygen sensor stores calibration and history data within the sensor. This allows you a “plug and play” 
system without re-calibration.

In this manual, you will find all of the information you will need to commission the Dissolved Oxygen sensor. Technical specifi-
cations, detection limits and dimensions can be found in chapter 7.

Please note that the user is responsible for complying with local and national regulations on the installation of electronic de-
vices. Any damage caused by incorrect use or unprofessional installation will not be covered by the warranty. All sensors and 
accessories supplied by TriOS Mess- und Datentechnik GmbH must be installed and operated in accordance with the specifi-
cations provided by TriOS Mess- und Datentechnik GmbH. All parts were designed and tested in accordance with international 
standards for electronic instruments. The device meets the requirements of the international regulations on electromagnetic 
compatibility. Please use only original TriOS accessories and cables to ensure reliable and correct operation of the devices.

Before using the device, read the manual carefully, and keep this manual on hand so it can be used later. Before commissioning 
the sensor, please make sure that you have read and understood the following safety precautions. Always make sure that the 
sensor is operated correctly. The safety precautions described on the following pages should ensure the reliable and correct 
operation of this device and any additional associated devices and should prevent injuries to yourself or other persons and 
damage to other equipment.

If the translation is at all different from the original German text, the German version is binding.

Copyright Notice 

All of the content in this manual, including texts, photographs and graphics, are protected by copyright. Unless expressly 
stated otherwise, TriOS Mess- und Datentechnik GmbH is the owner of the copyright. Violations of this copyright will be pun-
ishable according to section 106 ff of the German Copyright Act. The violator will be warned at his own expense and must pay 
compensation.

NOTICE

Summary of Contents for Dissolved Oxygen

Page 1: ...Dissolved Oxygen OPERATING INSTRUCTIONS...

Page 2: ......

Page 3: ...Installation 9 4 3 Support Tube Installation 10 5 Calibration 12 5 1 Two Point Calibration 12 5 1 1 Offset Calibration 12 5 1 2 Slope Calibration 12 5 2 One Point Calibration 13 5 3 Measurement Prope...

Page 4: ...sensors and accessories supplied by TriOS Mess und Datentechnik GmbH must be installed and operated in accordance with the specifi cations provided by TriOS Mess und Datentechnik GmbH All parts were...

Page 5: ...tion may cause moderate injury Electromagnetic Waves Devices that radiate strong electromagnetic waves can influence the measurement data or result in a malfunction of the sen sor Avoid using the foll...

Page 6: ...lified experts authorized byTriOS Devices from TriOS Mess und Datentechnik GmbH meet the highest safety standards Repairs to the device that involve the replacement of the connecting cable must be don...

Page 7: ...to use when it is handled according to the instructions in this user manual 1 6 Disposal Information At the end of the device s life or use the device and its accessories can be returned to the manuf...

Page 8: ...sensor can even be used in applications with very weak flow of water The sensor offers the following advantages Low operating costs due to reduced maintenance work no electrolyte changes Greater calib...

Page 9: ...Warranty Customer Service Contact Keyword Index Accessories 2 2 Scope of Delivery The shipment contains the following components Sensor Operating Instructions Accessories if applicable Keep the origin...

Page 10: ...Ensure correct polarity of the operating voltage or otherwise the sensor may be damaged 1 RS 485 A 2 RS 485 B 6 Power 12 VDC 7 Ground Power Ser Interface NOTICE The sensor is ready for initial startup...

Page 11: ...r water Standard operation of the sensor is carried out by immersing it into the medium The sensor can either hang freely or be mounted at 45 For measurement you must eliminate bubbles trapped under t...

Page 12: ...00B00 4136 ZM111710 Mechanik Halterohr 9 Version 1 1 Update January 20 AQUALABO CONTROLE 35 Rue Michel Marion 56850 CAUDAN FRANCE Tel 33 0 2 97 89 25 30 Fax 33 0 2 97 76 55 72 Long pole The long poles...

Page 13: ...unction Maintenance Commissioning Introduction General Information FAQ Technical Data Warranty Customer Service Contact Keyword Index Accessories 2 Pull the complete cable through 3 Fix the sensor wit...

Page 14: ...ut as follows 5 1 1 Offset calibration The sensor must be cleaned before calibration see chapter 6 Immerse the sensor in a water sulphite solution sulphite con centration 2 in order to determine the z...

Page 15: ...t electronics in the form of functions The sensor can therefore determine the oxygen concentration of the measurement medium in order to digitally transmit the influencing factors above in compensated...

Page 16: ...peration it should be rinsed prior to being stored and the protective cap should be fitted with the protective case and a moist absorbent surface like cotton 6 1 Cleaning and Upkeep Rinse meticulously...

Page 17: ...avoid incorrect deliveries each return package must first be reported to the customer service You will then receive a numbered RMA form which you need to fill out completely check and send back to us...

Page 18: ...ion Via NTC compensation active for temperature lower than 0 C Measurement range temperature 0 50 C Resolution temperature 0 01 C Accuracy temperature 0 5 C Membrane Cap No cross sensitivity with pH 1...

Page 19: ...cessories Calibration maintenance interval 2 years Warranty 1 year EU US 2 years on electronics All wearing parts are not included in the warranty INSTALLATION Max pressure 5 bar 72 5 psig Protection...

Page 20: ...able A built in valve allows the use of compressed air cleaning for the sensors The TriBox3 also has various interfaces including an IEEE 802 3 Ethernet inter face an IEEE 802 11 b g n interface a USB...

Page 21: ...sumables such as light sources are not included in the warranty The warranty is subject to the following conditions The device and all accessories must be installed as described in the corresponding m...

Page 22: ...Customer Service If you are having a problem with the sensor please contact TriOS customer service To send back the sensor please request an RMA number from customer service Technical support contacts...

Page 23: ...ssories 11 Contact We are constantly working to improve our devices Visit our website for news and information If you have found an error or bug in one of the devices or programs please let us know Cu...

Page 24: ...pressure 13 B Biological safety 3 Bypass installation 9 C Calibration 12 CE certification 24 Certificates approvals 5 Cleaning 14 Contact 21 Copyright 2 Customer service 20 D Disposal 5 E Electrical i...

Page 25: ...tact Keyword Index Accessories P Product Identification 6 Q R Rating plate 6 Reagents 3 Returns 15 RMA number 15 S Safety instructions 3 Salinity 13 Scope of delivery 7 Slope Calibration 12 Specificat...

Page 26: ...res conformity of the product TriOS GmbH d clare la conformit du produit Bezeichnung eCHEM Sauerstoff Product name eCHEM Oxygen Designation Typ Type Type Art Nr 90S531100 90S531130 Art Nr 90S534100 90...

Page 27: ...igned 16 bit integer Value range 0x0000 0xFFFF Bits16 1 Register contains a bitmask where every bit has a special meaning This is most often used for parameter selection where Bit 1 corresponds to the...

Page 28: ...and 1 stop bit Temporary coefficients W 332 Bits32 Each calibration coefficient Offset Scaling has a corresponding bit in this two registers Bit 1 Offset of temperature sensor Bit 2 Scaling of tempera...

Page 29: ...8 with 00 00 00 00 00 01 00 00 To use a correction for the atmospheric pressure it has to be written into the registers 95 96 as a float unit hPa and activated in the registers 166 167 or 168 with 00...

Page 30: ...r averaging perform offset calibration hold sensor in clean water 10 Min No Yes move sensor slowly in a Na2 SO3 solution for 5 minutes 2 Measurement point 1 Measurement point trigger measurement and r...

Page 31: ...ion Na2SO3 a tip of a teaspoon dissolved in water and move the sensor around in the solution Leave the sensor in the solution until the measurement values have stabilized 5 Measurements have to be tri...

Page 32: ...nt Point by putting the sensor in clean water for 10 minutes taking the sensor out holding it in air and continuously perform measurements in air and reading the results Saving the calibration 10 To a...

Reviews: