background image

6

D01-903en201912 Manual Dissolved Oxygen

Introduction

 

//

  Dissolved Oxygen

Us

e

Us

e

Calibr

ation

Calibr
ation

M

alfunc

tion &

M

ain

tenanc

e

M

alfunc

tion &

 M

ain
tenanc

e

Commissioning

Commissioning

In

tr

oduc

tion

In

tr

oduc

tion

G

ener

al 

Inf

or

ma

tion

G

ener

al 

Inf

or

ma
tion

FA

Q

FA

Q

Technical 

Da

ta

Technical 

Da

ta

W

ar

ran

ty

W

ar

ran

ty

Cust

omer 

Ser

vic

e

Cust
omer

Ser

vic

e

Con

tac

t

Con

tac
t

Key

w

or

d I

nde

x

Key
w

or

d I

nde
x

Ac

cessor

ies

Ac

cessor

ies

2 Introduction

2.1 Product Identification

There is a rating plate on the sensor with the following information that you can use to uniquely identify the product:

Serial number

Product type

Power supply

Interface

In addition to the product bar code, the rating plate includes the TriOS Mess- und Datentechnik GmbH logo and the   quality 
label.

Please note that the specifications given here are for illustration purposes only and may be different depending on the version 
of the product.

The Dissolved Oxygen sensor applies the luminescence-based optical measurement technology and measures reliably and 
accurately. With low consumables and maintenance required, the Dissolved Oxygen sensor gives an immediate return on the 
investment. The only intervention required is to replace the Membrane Cap every two years.

The sensor can even be used in applications with very weak flow of water.

The sensor offers the following advantages:

• Low operating costs due to reduced maintenance work (no electrolyte changes)

• Greater calibration intervals due to low drift behaviour

• No polarization voltage required 

• High measuring accuracy, even for low concentrations 

• Rapid response times

• No minimum inflow (no oxygen consumption)

The sensor features excellent interference immunity thanks to the integrated preamplifier and digital signal processing. The 
measured value for dissolved oxygen is automatically compensated with the temperature, air pressure, and salinity (salt con-
tent), and transferred without interference to the connected display unit and controller via a digital interface. The membrane 
cap is easy to replace, meaning the sensor is very easy to maintain. The current calibration data is saved directly in the sensor 
electronics. As a result, the Plug and Play function of the system is enabled without the need for recalibration. The sensor also 
includes a log book containing the last ten successful calibrations in the form of a ring buffer.

Assembled 

in Europe

Serial No

903-17-A7135

Type

DO VA 2m

Sensor Power

12 VDC

Sensor Interface

Modbus RTU

TriOS eCHEM Serie

903-17-A7135

Summary of Contents for Dissolved Oxygen

Page 1: ...Dissolved Oxygen OPERATING INSTRUCTIONS...

Page 2: ......

Page 3: ...Installation 9 4 3 Support Tube Installation 10 5 Calibration 12 5 1 Two Point Calibration 12 5 1 1 Offset Calibration 12 5 1 2 Slope Calibration 12 5 2 One Point Calibration 13 5 3 Measurement Prope...

Page 4: ...sensors and accessories supplied by TriOS Mess und Datentechnik GmbH must be installed and operated in accordance with the specifi cations provided by TriOS Mess und Datentechnik GmbH All parts were...

Page 5: ...tion may cause moderate injury Electromagnetic Waves Devices that radiate strong electromagnetic waves can influence the measurement data or result in a malfunction of the sen sor Avoid using the foll...

Page 6: ...lified experts authorized byTriOS Devices from TriOS Mess und Datentechnik GmbH meet the highest safety standards Repairs to the device that involve the replacement of the connecting cable must be don...

Page 7: ...to use when it is handled according to the instructions in this user manual 1 6 Disposal Information At the end of the device s life or use the device and its accessories can be returned to the manuf...

Page 8: ...sensor can even be used in applications with very weak flow of water The sensor offers the following advantages Low operating costs due to reduced maintenance work no electrolyte changes Greater calib...

Page 9: ...Warranty Customer Service Contact Keyword Index Accessories 2 2 Scope of Delivery The shipment contains the following components Sensor Operating Instructions Accessories if applicable Keep the origin...

Page 10: ...Ensure correct polarity of the operating voltage or otherwise the sensor may be damaged 1 RS 485 A 2 RS 485 B 6 Power 12 VDC 7 Ground Power Ser Interface NOTICE The sensor is ready for initial startup...

Page 11: ...r water Standard operation of the sensor is carried out by immersing it into the medium The sensor can either hang freely or be mounted at 45 For measurement you must eliminate bubbles trapped under t...

Page 12: ...00B00 4136 ZM111710 Mechanik Halterohr 9 Version 1 1 Update January 20 AQUALABO CONTROLE 35 Rue Michel Marion 56850 CAUDAN FRANCE Tel 33 0 2 97 89 25 30 Fax 33 0 2 97 76 55 72 Long pole The long poles...

Page 13: ...unction Maintenance Commissioning Introduction General Information FAQ Technical Data Warranty Customer Service Contact Keyword Index Accessories 2 Pull the complete cable through 3 Fix the sensor wit...

Page 14: ...ut as follows 5 1 1 Offset calibration The sensor must be cleaned before calibration see chapter 6 Immerse the sensor in a water sulphite solution sulphite con centration 2 in order to determine the z...

Page 15: ...t electronics in the form of functions The sensor can therefore determine the oxygen concentration of the measurement medium in order to digitally transmit the influencing factors above in compensated...

Page 16: ...peration it should be rinsed prior to being stored and the protective cap should be fitted with the protective case and a moist absorbent surface like cotton 6 1 Cleaning and Upkeep Rinse meticulously...

Page 17: ...avoid incorrect deliveries each return package must first be reported to the customer service You will then receive a numbered RMA form which you need to fill out completely check and send back to us...

Page 18: ...ion Via NTC compensation active for temperature lower than 0 C Measurement range temperature 0 50 C Resolution temperature 0 01 C Accuracy temperature 0 5 C Membrane Cap No cross sensitivity with pH 1...

Page 19: ...cessories Calibration maintenance interval 2 years Warranty 1 year EU US 2 years on electronics All wearing parts are not included in the warranty INSTALLATION Max pressure 5 bar 72 5 psig Protection...

Page 20: ...able A built in valve allows the use of compressed air cleaning for the sensors The TriBox3 also has various interfaces including an IEEE 802 3 Ethernet inter face an IEEE 802 11 b g n interface a USB...

Page 21: ...sumables such as light sources are not included in the warranty The warranty is subject to the following conditions The device and all accessories must be installed as described in the corresponding m...

Page 22: ...Customer Service If you are having a problem with the sensor please contact TriOS customer service To send back the sensor please request an RMA number from customer service Technical support contacts...

Page 23: ...ssories 11 Contact We are constantly working to improve our devices Visit our website for news and information If you have found an error or bug in one of the devices or programs please let us know Cu...

Page 24: ...pressure 13 B Biological safety 3 Bypass installation 9 C Calibration 12 CE certification 24 Certificates approvals 5 Cleaning 14 Contact 21 Copyright 2 Customer service 20 D Disposal 5 E Electrical i...

Page 25: ...tact Keyword Index Accessories P Product Identification 6 Q R Rating plate 6 Reagents 3 Returns 15 RMA number 15 S Safety instructions 3 Salinity 13 Scope of delivery 7 Slope Calibration 12 Specificat...

Page 26: ...res conformity of the product TriOS GmbH d clare la conformit du produit Bezeichnung eCHEM Sauerstoff Product name eCHEM Oxygen Designation Typ Type Type Art Nr 90S531100 90S531130 Art Nr 90S534100 90...

Page 27: ...igned 16 bit integer Value range 0x0000 0xFFFF Bits16 1 Register contains a bitmask where every bit has a special meaning This is most often used for parameter selection where Bit 1 corresponds to the...

Page 28: ...and 1 stop bit Temporary coefficients W 332 Bits32 Each calibration coefficient Offset Scaling has a corresponding bit in this two registers Bit 1 Offset of temperature sensor Bit 2 Scaling of tempera...

Page 29: ...8 with 00 00 00 00 00 01 00 00 To use a correction for the atmospheric pressure it has to be written into the registers 95 96 as a float unit hPa and activated in the registers 166 167 or 168 with 00...

Page 30: ...r averaging perform offset calibration hold sensor in clean water 10 Min No Yes move sensor slowly in a Na2 SO3 solution for 5 minutes 2 Measurement point 1 Measurement point trigger measurement and r...

Page 31: ...ion Na2SO3 a tip of a teaspoon dissolved in water and move the sensor around in the solution Leave the sensor in the solution until the measurement values have stabilized 5 Measurements have to be tri...

Page 32: ...nt Point by putting the sensor in clean water for 10 minutes taking the sensor out holding it in air and continuously perform measurements in air and reading the results Saving the calibration 10 To a...