Installation
This chapter discusses the proper installation and mounting of the
OSCAR
sensor. Pay
special attention to this section and follow the safety precautions to protect the sensor and
yourselves from harm and injury.
Before the
OSCAR
sensor is put into operation, it should be ensured that it is securely
fastened and that all connections are wired correctly.
3.1 Electrical installation
3.1.1 Power supply
The
OSCAR
sensor is designed for 12 - 24 VDC. With the
G2 Interface Box
a standard 12
or 24 VDC power supply can be used with a minimum output current of 200 mA.
Connect the 8 pin underwater connector to the
OSCAR
. Be careful aligning the pins to the
corresponding sockets (Fig. 3). Use the locking sleeve to fix the connector. Turn the sleeve
clockwise onto the bulkhead connector like shown in Fig. 4.
Fig. 3. Carefully aligning the pins onto the connector