17
Triple Solar assembly instruction PVT heat pump panels March 2020
Attention:
The TS clamping profile must be clamped accurately both horizontally and vertically. The TS
clamping profile cannot shift sideways after this.
Mounting connecting hoses and/or connection plugs
1) Grease connecting hoses and/or connecting plugs (use silicone grease only, see also the
instructions for the connecting hoses in chapter 7.2).
2) Slide connecting hoses and plugs into the header at the intended location.
3) Place retaining clips over the header and the slot in the connecting hose/plug. See figure 7.4-a,
location indicated with a D.
Connecting the PV panels electrically
•
The instruction for the electrical connection of the heat pump panels is identical to regular PV
panels.
•
The electrical connection may only be carried out by qualified electricians. We therefore
recommend that you accept invitations from your inverter supplier to attend the free certification
courses.
•
Depending on the situation and requirements of the customer, the choice can be made to use
optimizers or string inverters.
Mount optimizers, if you use them, as far as possible at the bottom edge of your panel field so that you can
always access them easily for maintenance. If necessary, use extension cables to connect the panels to the
optimizers in higher rows. (see figure 7.5-a)
C.
D
Figure 7.3-a bend the ridge upwards
Figure 7.4-a Attach retaining clip at (D)