Function
Range
Resolution Accuracy ±
(% of r digits)
Resistance
600.0Ω
0.1Ω
6.000kΩ
1Ω
±(1.5% +5 digits)
60.00kΩ
10Ω
600.0kΩ
100Ω
6.000MΩ
1kΩ
±(2.0% +10 digits)
60.00MΩ
10kΩ
Input Protection:
600V AC RMS or 600V DC
Function
Range
Resolution Accuracy ±
(% of r digits)
Capacitance
60.00nF
10pF
±(5.0% +35 digits)*
600.0nF
100pF
6.000µF
0.001µF
±(3.0% +5 digits)
60.00µF
0.01µF
600.0µF
0.1µF
6000µF
1µF
±(5.0% +5 digits)
Input Protection:
600V AC RMS or 600V DC
*Accuracy is not stated below 6nF
Function
Range
Resolution Accuracy ±
(% of r digits)
Temperature
-4°F to 1400°F
0.1°F
±(2.0% +9ºF)
-20°C to 760°C
0.1°C
±(2.0% +5ºC)
Input Protection:
600V AC RMS or 600V DC
Maintenance
www.
.com
information@itm.com
1.800.561.8187