MAX/MIN/AVG Button
1. Momentarily press the MAX/MIN/AVG button to activate
the MAX/MIN/Average mode. “MAX” will appear on the
LCD display and the meter will display and hold the
highest reading. The meter will update the reading when
a higher “max” occurs.
2. Momentarily press the MAX/MIN/AVG button again to
view the lowest reading. “MIN” will appear on the LCD
display and the meter will display and hold the lowest
reading. The meter will update the reading when a lower
“min” occurs.
3. Momentarily press the MAX/MIN/AVG button once more
to view the average reading. The “AVG” symbol will
appear on the LCD display and the meter will display the
running average. The meter will update the reading when
the average value changes.
4. Press and hold the MAX/MIN/AVG button to end
MAX/MIN/Average and return to normal operation.
NOTE:
The meter does not Auto Range when MAX/MIN/AVG is
active. The meter
will display OL if the reading exceeds the range.
When this occurs, exit MAX/MIN/AVG and use the RANGE button
to select a higher range. MAX/MIN/ AVG does not work on
Frequency, Duty Cycle or Capacitance.
Flashlight/PEAK Button
Momentarily press the
PEAK
button to turn the flashlight on
and off.
The PEAK function is accessible when measuring AC
Voltage or Current. It captures and displays the highest
positive peak and the highest negative peak of the AC
waveform.