Operation
1.
Install 4 fresh AAA batteries or connect the AC adaptor.
2.
Set-up the datalogger using the software provided.
3.
Connect the voltage test leads or the current probe to the meter
and hen to the AC source to be measured.
4.
Press and Hold the START/STOP button for four seconds to start
recording. The “REC” icon will appear in the display indication that
recording has begun.
5.
Press and Hold the START/STOP button for four seconds to stop
recording. The “REC” icon will disappear from the display.
6.
Remove the probe, connect the datalogger to a PC and use the
supplied software to download the data.
7.
After each recording you will need to connect to the PC and supplied
software to download the data and set up for the next recording.
You, as the end user, are legally bound (
Battery ordinance
) to
return all used batteries and accumulators;
disposal in the
household garbage is prohibited!
You can hand over your used batteries / accumulators at
collection points in your community or wherever batteries /
accumulators are sold!
Disposal:
Follow the valid legal stipulations in respect of the
disposal of the device at the
end of its lifecycle.
Note: If the clock does not set to the correct time, replace the 3V button