200507083  93-2477

Battery Replacement

FCC RADIO/TV INTERFERENCE NOTICE: 

(FOR CLASS A MODELS)

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with
the instruction manual, may cause interference to radio communications. Operation of this equipment is likely to cause harmful interference in which case the user will be required to correct the interference
at his own expense. The user must use shielded cables and connectors with this product. Any changes or modifications to this product not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.

FCC RADIO/TV INTERFERENCE NOTICE: 

(FOR CLASS B MODELS)

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual,
may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference using one or more of the following measures: reorient or relocate
the receiving antenna; increase the separation between the equipment and the receiver; connect the equipment into an outlet on a circuit different from that which the receiver is connected; consult
the dealer or an experienced radio/television technician for help. The user must use shielded cables and connectors with this product. Any changes or modifications to this product not expressly
approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC rules. Operation is subject to the following 2 conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

Regulatory Compliance Identification Numbers

For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series number. The series number can be found on the product name-
plate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to the series number. The series number should not be
confused with the marking name or model number of the product.

This product designed and engineered in the USA.

Note on Labeling

Two symbols are used on the label.
V~  : AC Voltage
V    : DC Voltage

Under normal conditions, the original batteries in your UPS will last many years. See Safety sec-
tion before replacing batteries. The batteries are designed for hot-swap replacement (i.e. leaving the
UPS in ON mode), but some qualified service personnel may wish to put the UPS in the OFF mode
and disconnect equipment before proceeding.

1U UPS Models

Procedure

Remove Front
Panel

Disconnect
Batteries

Remove/Dispose of
Batteries

Add Batteries

Connect Batteries

Attach connectors: black-
to-black and red-to-red.

Replace Front
Panel

6

5

4

3

2

1

2U UPS Models

1

6

2

5

3

4

1

6

2

5

3

4

Warranty Registration

Visit www.tripplite.com/warranty today to register the warranty for your new Tripp Lite product.
You'll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product!*

* No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.

200507083 93-2477 Sinewave SmartPro Rackmount UPS OM.qxd  10/19/2005  10:35 AM  Page 12

Summary of Contents for 2POSTRMKITWM

Page 1: ...erved Audio Video Automatic Voltage Regulation AVR UPS Systems Intelligent Line Interactive Operation Sine Wave Output 500VA 1500VA Capacities Extended Run Options Except 500VA sine wave output on line PWM output on battery Not suitable for mobile applications Battery Replacement 12 Optional Installation 6 WARRANTY REGISTRATION Register online today for a chance to win a FREE Tripp Lite product ww...

Page 2: ...tions in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors or extension cords to the output of your UPS This might overload the UPS and will void the surge suppressor and UPS warranties Battery Warnings Batteries can present a risk of electrical shock and burn from high shor...

Page 3: ... does not include an adjustable rackmount shelf kit skip steps 1 and 2 Connect the two segments of each shelf using the included screws and nuts Leave the screws slightly loose so that the shelves can be adjusted in the next step Adjust each shelf to fit your rack then mount them in the lowest available space of your rack with the screws nuts and washers provided Note that the support ledges shoul...

Page 4: ...r equipment to the rack by passing the screws nuts and washers provided through its mounting ears and into the rack rails D C B A 1 2 B A D C 1 2 Tower Mounting 4 Mount all UPS models in an upright tower position using included hardware The user must deter mine the fitness of hardware and procedures before mounting All UPS Models Stand your UPS on its side with the LED Control panel at the top Att...

Page 5: ...PS is designed to support Media Center PCs home automa tion systems and audio video components only You will overload the UPS if the total VA ratings for all the equipment you connect exceeds the UPS s Output Capacity To find your equipment s VA ratings look on their nameplates If the equipment is listed in amps multiply the num ber of amps by 120 to determine VA Example 1 amp 120 120 VA If you ar...

Page 6: ...ine surge suppressor do not connect a phone line to this port External Battery Connection select models only Your UPS comes with a robust internal battery sys tem external batteries are needed only to extend run time Adding external batteries will increase recharge time as well as runtime The illustration see shows the location of your UPS s External Battery Connector where you will insert the bat...

Page 7: ...PS however will not perform a self test if the UPS is not turned on see ON OFF STANDBY Button description CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical grounding and may introduce a damaging surge into your system connections Results of a Self Test The test will last approximately 10 seconds as the UPS switches to battery to test its load capacity and batter...

Page 8: ...event of a blackout or brownout BATTERY CHARGE LED when the UPS is operating from utility power this LED indicates the approximate charge state of the UPS s internal batteries red indicates the batteries are beginning to charge yellow indicates the batteries are roughly midway through charging and green indicates the batteries are fully charged When the UPS is operating from battery power during a...

Page 9: ...panel which provide surge only not battery backup protection Select models also feature outlets labelled UNSWITCHED which may not be remotely switched off See software instructions for details Communications Ports USB or RS 232 These ports connect your UPS to any Media Center PC or home automation system Use with Tripp Lite s PowerAlert Software and included cables to enable your Media Center PC h...

Page 10: ...st mode so that the effect on the equip ment of any waveform distortions in the UPS s output can be evaluated without disrupting Media Center PC or home automation system operation External Battery Connector Select Models Only Use to connect Tripp Lite external battery packs for additional runtime Refer to instructions available with the battery pack for complete connection information and safety ...

Page 11: ... This is the most common cause of service inquiries which can be easily remedied by following the resetting instructions in this manual 2 If the problem continues do not contact or return the UPS to the dealer Instead call Tripp Lite at 773 869 1233 A service technician will ask for the UPS s model number serial number and purchase date and will attempt to correct the problem over the phone 3 If t...

Page 12: ...rcuit different from that which the receiver is connected consult the dealer or an experienced radio television technician for help The user must use shielded cables and connectors with this product Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with part 15 of...

Reviews: