Basic Operation 

continued

Indicator Lights (Front Panel)

All Indicator Light descriptions apply when the UPS is plugged into a wall outlet
and turned ON.

“POWER” LED: 

this green LED lights continuously when the UPS is ON and

supplying connected equipment with AC power from a utility source. The LED
flashes and an alarm sounds (4 short beeps followed by a pause) to indicate the
UPS is operating from its internal batteries during a blackout or severe
brownout. If the blackout or severe brownout is prolonged, you should shut
down your equipment since internal battery power will eventually be depleted.
See “BATTERY CHARGE” LED description below. 

“VOLTAGE CORRECTION” LED:

this green LED lights continuously

whenever the UPS is automatically correcting high or low AC voltage on the
utility line without the assistance of battery power. The UPS will also emit a
slight clicking noise. These are normal, automatic operations of the UPS, no
action is required on your part.

“OUTPUT LOAD LEVEL” LED: 

this multicolored LED indicates the

approximate electrical load of equipment connected to the UPS's AC outlets. It
will turn from green (light load) to yellow (medium load) to red (overload). If
the LED is red (either illuminated continuously or flashing), clear the overload
immediately by unplugging some of your equipment from the outlets until the
LED changes from red to yellow (or green). CAUTION! Any overload that is
not corrected by the user immediately may cause the UPS to shut down and
cease supplying output power in the event of a blackout or brownout.

“BATTERY CHARGE” LED: 

when the UPS is operating from utility power,

this LED indicates the approximate charge state of the UPS's internal batteries:
red indicates the batteries are beginning to charge; yellow indicates the batteries
are roughly midway through charging; and green indicates the batteries are fully
charged. When the UPS is operating from battery power during a blackout or
severe brownout, this LED indicates the approximate amount of energy (ulti-
mately affecting runtime) which the UPS’s batteries will provide: red indicates
a low level of energy; yellow indicates a medium level of energy; and green
indicates a high level of energy. Since the runtime performance of all UPS bat-
teries will gradually deplete over time, it is recommended that you periodically
perform a self-test (see MUTE/TEST Button description) to determine the energy
level of your UPS batteries BEFORE a blackout or severe brownout occurs.
During a prolonged blackout or severe brownout, you should shut down your
equipment since battery power will eventually be depleted. When the LED turns
red and an alarm sounds continuously, it indicates the UPS's batteries are nearly
out of power and UPS shut down is imminent.

“BATTERY WARNING” LED:

this LED lights red and an alarm sounds

intermittently after you initiate a self test (See “MUTE/TEST” Button description)
to indicate the UPS batteries need to be recharged or replaced. Allow the UPS
to recharge continuously for 12 hours, and repeat the self-test. If the LED con-
tinues to light, contact Tripp Lite for service. If your UPS requires battery
replacement, visit www.tripplite.com to locate the specific Tripp Lite replace-
ment battery for your UPS.

8

200507083 93-2477 Sinewave SmartPro Rackmount UPS OM.qxd  10/19/2005  10:35 AM  Page 8

Summary of Contents for 2POSTRMKITWM

Page 1: ...erved Audio Video Automatic Voltage Regulation AVR UPS Systems Intelligent Line Interactive Operation Sine Wave Output 500VA 1500VA Capacities Extended Run Options Except 500VA sine wave output on line PWM output on battery Not suitable for mobile applications Battery Replacement 12 Optional Installation 6 WARRANTY REGISTRATION Register online today for a chance to win a FREE Tripp Lite product ww...

Page 2: ...tions in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors or extension cords to the output of your UPS This might overload the UPS and will void the surge suppressor and UPS warranties Battery Warnings Batteries can present a risk of electrical shock and burn from high shor...

Page 3: ... does not include an adjustable rackmount shelf kit skip steps 1 and 2 Connect the two segments of each shelf using the included screws and nuts Leave the screws slightly loose so that the shelves can be adjusted in the next step Adjust each shelf to fit your rack then mount them in the lowest available space of your rack with the screws nuts and washers provided Note that the support ledges shoul...

Page 4: ...r equipment to the rack by passing the screws nuts and washers provided through its mounting ears and into the rack rails D C B A 1 2 B A D C 1 2 Tower Mounting 4 Mount all UPS models in an upright tower position using included hardware The user must deter mine the fitness of hardware and procedures before mounting All UPS Models Stand your UPS on its side with the LED Control panel at the top Att...

Page 5: ...PS is designed to support Media Center PCs home automa tion systems and audio video components only You will overload the UPS if the total VA ratings for all the equipment you connect exceeds the UPS s Output Capacity To find your equipment s VA ratings look on their nameplates If the equipment is listed in amps multiply the num ber of amps by 120 to determine VA Example 1 amp 120 120 VA If you ar...

Page 6: ...ine surge suppressor do not connect a phone line to this port External Battery Connection select models only Your UPS comes with a robust internal battery sys tem external batteries are needed only to extend run time Adding external batteries will increase recharge time as well as runtime The illustration see shows the location of your UPS s External Battery Connector where you will insert the bat...

Page 7: ...PS however will not perform a self test if the UPS is not turned on see ON OFF STANDBY Button description CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical grounding and may introduce a damaging surge into your system connections Results of a Self Test The test will last approximately 10 seconds as the UPS switches to battery to test its load capacity and batter...

Page 8: ...event of a blackout or brownout BATTERY CHARGE LED when the UPS is operating from utility power this LED indicates the approximate charge state of the UPS s internal batteries red indicates the batteries are beginning to charge yellow indicates the batteries are roughly midway through charging and green indicates the batteries are fully charged When the UPS is operating from battery power during a...

Page 9: ...panel which provide surge only not battery backup protection Select models also feature outlets labelled UNSWITCHED which may not be remotely switched off See software instructions for details Communications Ports USB or RS 232 These ports connect your UPS to any Media Center PC or home automation system Use with Tripp Lite s PowerAlert Software and included cables to enable your Media Center PC h...

Page 10: ...st mode so that the effect on the equip ment of any waveform distortions in the UPS s output can be evaluated without disrupting Media Center PC or home automation system operation External Battery Connector Select Models Only Use to connect Tripp Lite external battery packs for additional runtime Refer to instructions available with the battery pack for complete connection information and safety ...

Page 11: ... This is the most common cause of service inquiries which can be easily remedied by following the resetting instructions in this manual 2 If the problem continues do not contact or return the UPS to the dealer Instead call Tripp Lite at 773 869 1233 A service technician will ask for the UPS s model number serial number and purchase date and will attempt to correct the problem over the phone 3 If t...

Page 12: ...rcuit different from that which the receiver is connected consult the dealer or an experienced radio television technician for help The user must use shielded cables and connectors with this product Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with part 15 of...

Reviews: