ADDITIONAL DISPLAY ITEMS

BATTERY INDICATORS

OPERATING MODE INDICATORS

TEST 

MUTE 

1

2

3

4

5

10

9

7

6

8

11

LCD Display

The LCD Display indicates a variety 
of UPS modes and operating 
conditions. To view the various 
screens, press the 

 button 

while the UPS is operating in line or 
battery power mode.  

The LCD DISPLAY is shown here 
fully illuminated to identify all 
available icons and labels. This is 
for explanation only—there are no 
operating modes where the screen 
is fully illuminated like this except 
for a few seconds as the UPS is first 
plugged in. 

5.  BATTERY CHARGE METER

 continuously reports battery charge level.

6.  LOAD LEVEL METER

 continuously reports load-level on UPS supported outlets.

7.  OVERLOAD ICON

 comes on to report that UPS supported outlets are overloaded.

8.  3-DIGIT DISPLAY

 lights along with associated labeling and icons to report a variety 

of UPS and site power related conditions.  

9.  3-DIGIT DISPLAY SUFFIX

 display labels will selectively illuminate to describe the 

unit of measurement the 3-digit display is currently reporting (V=volts, %=percent, 
A=amps, kW=kilowatts, Hz=frequency, Min=minutes).

10.  3-DIGIT DISPLAY PREFIXES

•  INPUT lights to indicate the 3-digit display is reporting an input condition (input 

voltage, input frequency) 

•  OUTPUT lights to indicate the 3-digit display is reporting an output condition 

(output voltage, output Hz, etc) 

•  BATTERY lights to indicate the 3-digit display is reporting a battery related 

condition (battery voltage)

•  ESTIMATED RUNTIME lights to indicate that the 3-digit display is currently 

reporting estimated runtime in minutes

11.  FAULT ICON

 lights to indicate a variety of possible UPS fault conditions (see Error 

Messages section for information on other reported faults)

1.  ON-LINE MODE ICON

 indicates that AC 

power is present and the UPS is running 

from an input line power source.

2.  AVR BUCK & AVR BOOST ICONS

 will 

selectively illuminate during line power 
mode to indicate Automatic Voltage 
Regulation (AVR) is engaged.  “AVR” 

& “BUCK” indicates an overvoltage 
condition and output is reduced back 

to usable levels.  “AVR” & “BOOST” 
indicates brownout/undervoltage 
conditions and output is boosted back 

to usable levels.  

3.  ON BATT ICON

 indicates that the UPS 

is running in battery mode, due to 
power failure or severe input voltage 

fluctuation.

4.  REPLACE BATTERY ICON

 will illuminate 

to inform users that the UPS battery is 
weak and requires replacement.

Basic Operation 

continued

Summary of Contents for AG-04F3

Page 1: ...lay 5 Display UPS Power Conditions 6 Enable Disable Alarm 6 Self Test 7 Error Messages 7 Features 8 Battery Replacement 9 Storage and Service 10 Product Registration 11 Owner s Manual TEST MUTE TEST MUTE 1111 W 35th Street Chicago IL 60609 USA tripplite com support Copyright 2020 Tripp Lite All rights reserved SmartPro is a registered trademark of Tripp Lite ...

Page 2: ...tor powered AC generator the generator must provide clean filtered computer grade output The mains socket outlet that supplies the UPS should be easily accessible and located near the UPS For use on a TN power distribution system of input power supply The UPS stored energy output device provides a TN power system Equipment Connection Warnings Use of this equipment in life support applications wher...

Page 3: ...following precautions should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles Wear rubber gloves and boots Do not lay tools or metal parts on top of batteries Disconnect the charging source and load prior to installing or maintaining the battery Remove battery grounds during installation and maintenance to reduce likelihood of shock...

Page 4: ...mon desktop items like printers scanners and other accessories not requiring battery support to these outlets Outlets marked BATTERY SURGE PROTECTED offer UPS battery backup support during power failures Connect your vital computer equipment into these outlets Your UPS is designed to support electronic equipment only You will overload the UPS if the total VA ratings for all the equipment connected...

Page 5: ...0 170 280V AC 1 175 275V AC 2 180 270V AC Plug equipment into the UPS Your UPS is designed to support electronic equipment only You will overload the UPS if the total VA ratings for all the equipment you connect to the Battery Surge and Noise Protected outlets exceed the UPS s Output Capacity To estimate your equipment s power requirements look on the nameplate If the equipment is listed in amps m...

Page 6: ...nutes 10 3 DIGIT DISPLAY PREFIXES INPUT lights to indicate the 3 digit display is reporting an input condition input voltage input frequency OUTPUT lights to indicate the 3 digit display is reporting an output condition output voltage output Hz etc BATTERY lights to indicate the 3 digit display is reporting a battery related condition battery voltage ESTIMATED RUNTIME lights to indicate that the 3...

Page 7: ...to report ESTIMATED RUNTIME To advance to the next screen press the button The screens are displayed in this order 1 ESTIMATED RUNTIME 2 OUTPUT VOLTAGE 3 OUTPUT FREQUENCY 4 OUTPUT LOAD PERCENTAGE 5 OUTPUT LOAD WATTS 6 BATTERY VOLTAGE Basic Operation continued Enable Disable Alarm To enter silent mode press and hold the button until you hear an audible beep The icon will appear on the LCD screen to...

Page 8: ...oad the and icons will light and the LCD screen will report the output load percentage CRITICAL FAULT SCREENS Some more severe fault conditions will result in the UPS shutting off power to the UPS supported output receptacles At this point the LCD screen will report any one of 5 possible on screen fault codes Some faults such as output short circuit overload and bad battery can be user corrected b...

Page 9: ...SB Communication Port This port can connect your UPS to any computer for automatic file saves and unattended shutdown in the event of a power failure Use with Tripp Lite s PowerAlert Software available as a FREE download at tripplite com and appropriate USB cable A USB cable is included with your UPS This connection is optional Your UPS will work properly without this connection Note This UPS Syst...

Page 10: ...tibility and ordering visit Tripp Lite on the Web at tripplite com support battery index cfm To Replace the Batteries 1 Remove screw at the bottom of the unit s front panel 2 Carefully pull the front panel away from the UPS 3 Remove the battery support bar 4 Carefully pull the old batteries from the UPS and disconnect them 5 Connect the new batteries in exactly the same manner as the old ones posi...

Page 11: ...re that the service problem does not originate from a misreading of the instructions 2 If the problem continues do not contact or return the product to the dealer Instead visit tripplite com support 3 If the problem requires service visit tripplite com support and click the Product Returns link From here you can request a Returned Material Authorization RMA number which is required for service Thi...

Page 12: ...tion for Tripp Lite Customers and Recyclers European Union Under the Waste Electrical and Electronic Equipment WEEE Directive and implementing regulations when customers buy new electrical and electronic equipment from Tripp Lite they are entitled to Send old equipment for recycling on a one for one like for like basis this varies depending on the country Send the new equipment back for recycling ...

Reviews: