Basic Operation (Front Panel) 

continued

•  If the “FAULT” icon remains lit and the alarm continues to sound after the test, the battery-

supported outlets are overloaded. To clear the overload, unplug some of your equipment from 

the battery-supported outlets and repeat the self-test until the “FAULT” icon is no longer lit and 

the alarm is no longer sounding. 

Note:

 The alarm beeps once per minute.

CAUTION! Any overload that is not corrected by the user immediately following a self-

test may cause the UPS to shut down and cease supplying output power in the event 

of a blackout or brownout.

•  If the “REPLACE” icon remains lit and the alarm continues to sound after the test, the UPS 

batteries need to be recharged or replaced. Allow the UPS to recharge continuously for 24 

hours, and repeat the self-test. If the icon continues to illuminate after repeated self tests, 

contact  Tripp  Lite  for  service.  Battery  replacement  should  only  be  performed  by  qualified 

service personnel. If the UPS requires battery replacement, Tripp Lite offers a complete line of 

replacement batteries at www.tripplite.com. 

Note:

 The alarm beeps once per minute.

3

 LCD Status Screen

 

The LCD Status Screen indicates a variety 

of UPS operational conditions. All 

descriptions apply when the UPS is plugged 

into an AC outlet and turned on.

 

Note: The LCD will illuminate for 1 second 

when the UPS is plugged in, before it is 

turned on. The LCD Status Screen can be 

rotated for easy viewing, regardless of 

whether the UPS is in a horizontal or 

vertical position. To rotate the LCD Status 

Screen: insert a small tool in the slots on 

the sides of the screen to pop it out of the 

UPS housing; rotate the screen, and snap 

it back into the UPS housing.

3a

 

“Input  Voltage”  Meter:

 This meter measures, in real time, the AC voltage that the UPS 

system is receiving from the utility wall outlet. Although the Meter may occasionally display 

input voltages which stray outside the range of standard computer tolerance (due to poor 

quality utility service), rest assured that the UPS is designed (through the use of automatic 

voltage regulation) to continuously supply connected equipment with stable, computer-grade 

output  voltage.  In  the  event  of  a  blackout  (power  loss),  severe  brownout  (low  power)  or 

overvoltage  (high  power),  the  UPS  will  rely  on  its  internal  battery  to  supply  computer-grade 

output voltage.

3b

 

“BATTERY  CAPACITY”  Meter: 

This  meter  displays  the  approximate  charge  level  (in  20% 

increments) of the UPS's internal battery. During a blackout or severe brownout, the UPS will 

switch to battery power, the “ON BAT” icon will be illuminated and the charge level will deplete.

3c

 

“AVR” (Automatic Voltage Regulation) Icon:

 This icon will illuminate whenever your UPS is 

automatically correcting AC line voltage without depleting battery power. This is a normal, 

automatic operation of your UPS, and no action is required on your part.

3d

 

“REPLACE”  (Battery  Recharge/Replace)  Icon:

 This icon will illuminate and an alarm will 

sound after a self-test to indicate the UPS battery needs to be recharged or replaced. Allow 

the UPS to recharge continuously for 24 hours, and repeat the self-test. If the icon continues 

to illuminate, contact Tripp Lite for service. Battery replacement should only be performed by 

qualified service personnel. 

LCD Status Screen

3

3a

3g

3b

3c

3d

3e

3f

201207108 93-2663.indd   4

9/4/2012   3:15:57 PM

Summary of Contents for AGOM5357

Page 1: ...Espa ol 8 Storage Service 6 Copyright 2012 Tripp Lite All rights reserved All trademarks are the property of their respective owners Fran ais 15 Agency Series Numbers AGOM5516 AGOM5357 AGOM7082 W A R...

Page 2: ...of the life support equipment or to significantly affect its safety or effectiveness is not recommended Do not use this equipment in the presence of a flammable anesthetic mixture with air oxygen or n...

Page 3: ...Button description CAUTION The UPS must be plugged into a live AC outlet and turned on for 24 hours after initial installation to fully charge the UPS s internal battery Your connected equipment will...

Page 4: ...n the slots on the sides of the screen to pop it out of the UPS housing rotate the screen and snap it back into the UPS housing 3a Input Voltage Meter This meter measures in real time the AC voltage t...

Page 5: ...and line noise protection not battery backup Plug equipment that does not require battery backup during a utility power failure such as a printer scanner or fax machine into these outlets Battery Bac...

Page 6: ...uld be turned off and disconnected from the UPS Press and hold the ON OFF button for one second Your UPS will be completely turned off deactivated and will be ready for storage If you plan on storing...

Page 7: ...ician for help The user must use shielded cables and connectors with this product Any changes or modifications to this product not expressly approved by the party responsible for compliance could void...

Page 8: ...b sica 10 English 1 Almacenamiento y Servicio 14 Copyright 2012 Tripp Lite Todos los derechos reservados Todas las marcas registradas son propiedad de sus respectivos propietarios Fran ais 15 1111 W...

Page 9: ...falla de este equipo pueda razonablemente hacer suponer que causar fallas en el equipo de soporte de vida o afecte significativamente su seguridad o efectividad no est recomendado No use este equipo e...

Page 10: ...sobrecargado las salidas con respaldo de bater as con protecci n contra sobretensi n ejecute una auto prueba vea la descripci n del bot n MUTE TEST SILENCIO PRUEBA PRECAUCI N El UPS debe estar conect...

Page 11: ...Nota La alarma emite un pitido cada minuto 3 Pantalla LCD La pantalla LCD indica diferentes condiciones de operaci n del UPS Todas las descripciones se aplican cuando el UPS est conectado a una salid...

Page 12: ...didor CAPACIDAD DE BATER A mostrar un segmento de 20 de capacidad sombreado para indicar que las bater as del UPS est n casi agotadas debe guardar los archivos y apagar su equipo de inmediato 3f Icono...

Page 13: ...una toma de corriente alterna bipolar con toma de tierra para que funcione la protecci n contra sobretensiones en la l nea telef nica DSL La conexi n de su equipo a estos conectores es opcional Su UPS...

Page 14: ...una variedad de Garant as extendidas y Programas de servicio t cnico en el sitio Si desea m s informaci n sobre el servicio t cnico visite www tripplite com support Antes de devolver su producto para...

Page 15: ...onctionnement de base 17 English 1 Entreposage et entretien 20 2012 Tripp Lite Tous droits r serv s Toutes les marques d pos es sont la propri t de leurs propri taires respectifs Espa ol 8 1111 W 35th...

Page 16: ...rs de surtension ni rallonge lectrique la sortie de votre UPS Cela pourrait endommager l UPS et affecter les garanties de l liminateur de surtensions et de l UPS Avertissements de pile Votre UPS n exi...

Page 17: ...e sortie du UPS Pour conna tre le degr de VA de votre quipement consultez les plaques d identification Si l quipement est d sign en amps multipliez le nombre d amps par 120 pour d terminer le VA Exemp...

Page 18: ...e tension de sortie de cat gorie ordinateur 3b Compteur BATTERY CAPACITY ce compteur affiche le niveau de charge approximatif selon des augmentations de 20 de la pile interne du UPS Pendant une panne...

Page 19: ...le cordon du t l phone de la prise murale directement la prise t l DSL tiquet e IN Branchez un cordon de t l phone partir de la prise t l DSL tiquet e OUT directement au dispositif tre prot g Le syst...

Page 20: ...n continuelle Les sp cifications peuvent tre modifi es sans pr avis Entreposage et entretien Entreposage Tous les quipements branch s devraient tre teints puis d branch s du UPS pour viter de vider le...

Reviews: