Quick Start Guide

Installation

Basic Operation

AVRX Series UPS Systems

Not suitable for mobile applications.

1111 W. 35th Street, Chicago, IL 60609 USA 

www.tripplite.com/support

Copyright © 2018 Tripp Lite. All rights reserved.

This document explains the most important features of your UPS system. For additional information,  

download the Owner’s Manual PDF (in English, French, German or Russian) from 

www.tripplite.com/support/manuals

1

  Plug the UPS into an outlet. After plugging the UPS into a wall outlet, push the ON/OFF/TEST button for one second to turn the UPS on.

2

  Plug your equipment into the UPS. Select outlets will provide battery backup and surge protection; plug your computer, monitor and 

other critical devices here.* Select outlets will provide surge protection only; plug your printer and other non-essential devices here.

* Your UPS is designed to support electronic equipment only. You will overload the UPS if the total VA ratings for all the equipment you connect to the 
Battery Backup/Surge Protected outlets exceeds the UPS’s Output Capacity. To find your equipment’s VA ratings, look on their nameplates. If the equipment 
is listed in amps, multiply the number of amps by 230 to determine VA. (Example: 1 amp × 230 = 230VA). If you are unsure if you have overloaded the 
Battery Backup/Surge Protected outlets, run a self-test.

Note: 

UPS system will function properly upon initial startup; however, maximum runtime for the unit’s battery will only be accessible after it has been 

charged for 24 hours.

ON/OFF/TEST 

Button

ON/OFF LED

OVERLOAD/

CHECK 

BATTERY LED

Battery Backup/
Surge Protected 

Outlets

Surge-Only 

Protected 

Outlets

Communications Port  

(Select models only. For use 

with included USB cable.)

Tel/DSL/

Ethernet Line 

Protection

SAVE THESE INSTRUCTIONS

This manual contains instructions and warnings that should 
be followed during the installation, operation and storage of 

all Tripp Lite UPS Systems. Failure to heed these warnings 

may affect your warranty.

UPS Location Warnings

•   Install UPS indoors, away from excess moisture or heat, 

conductive contaminants, dust or direct sunlight.

•   Keep the indoor temperature between 32º F and 104º F 

(0º C and 40º C).

•   Leave adequate space around all sides of UPS for proper 

ventilation.

•   Do not mount unit with its front or rear panel facing down 

(at any angle). Mounting in this manner will seriously 

inhibit the unit’s internal cooling, eventually causing 
product damage not covered under warranty.

This marking indicates that this product should 
not be disposed with other household wastes 

throughout the EU. To prevent possible harm to the 
environment or human health from uncontrolled 
waste disposal, recycle it responsibly to promote 
the sustainable reuse of material resources. To 
return your used device, please use the return and 
collection systems or contact the retailer where the 
product was purchased. They can take this product 
for environmental safe recycling.

UPS Connection Warnings

•   Connect UPS directly to a properly grounded AC power 

outlet. Do not plug UPS into itself; this will damage the 

UPS.

•   Do not modify the UPS’s plug, and do not use an adapter 

that would eliminate the UPS’s ground connection.

•   Do not use extension cords to connect UPS to an AC 

outlet.

•   If UPS receives power from a motor-powered AC 

generator, the generator must provide clean, filtered, 
computer-grade output.

•   The mains socket outlet that supplies the UPS should be 

near the UPS and be easily accessible.

•   To remove AC voltage from the UPS, pull the plug from 

the outlet.

Equipment Connection Warnings

•   Use of this equipment in life support applications where 

failure of this equipment can reasonably be expected 

to cause the failure of the life support equipment or 

to significantly affect its safety or effectiveness is not 
recommended. 

•   Do not connect another UPS, surge suppressors or 

extension cords to the output of UPS. This might damage 
the UPS and may affect the surge suppressor and UPS 
warranties.

•   Connect the UPS to an outlet that is adequately 

protected against excess currents, short circuits and 
earth faults, as part of the building installation. The 
outlet protection for the UPS should be in series with the 
mains input.

Battery Warnings

•   Your UPS does not require routine maintenance. Do 

not open your UPS for any reason. There are no user-

serviceable parts inside.

•   Batteries can present a risk of electrical shock and 

burn from high short-circuit current. Observe proper 
precautions. Do not dispose of the batteries in a fire. Do 

not open the UPS or batteries. Do not short or bridge the 
battery terminals with any object. Unplug and turn off the 

UPS before performing battery replacement. Use tools 
with insulated handles. There are no user-serviceable 
parts inside the UPS. Battery replacement should be 

performed only by authorized service personnel using the 
same number and type of batteries (Sealed Lead-Acid). 

The batteries are recyclable. Refer to your local codes 
for disposal requirements or visit www.tripplite.com/
UPSbatteryrecycling for recycling information.  

Tripp Lite offers a complete line of UPS System 
Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite 

on the Web at www.tripplite.com/support/battery/index.
cfm to locate the specific replacement battery for your 
UPS.

Tripp Lite has a policy of continuous improvement. Product 
specifications are subject to change without notice.

Agency Model Numbers:  

AGOM7594 • AGOM7595 • AGOM7596 • AGOM7597 

AGOM7745 • AGOM7746 • AGOM7747 • AGOM7748

Important Safety Instructions