background image

2

SAVE THESE  INSTRUCTIONS!

This manual contains important instructions and warnings that should be followed during the installation, operation and storage of this product.

Location Warnings

• Although your Inverter is moisture resistant, it is NOT waterproof. Flooding the unit with water will cause it to short circuit 

and could cause personal injury due to electric shock. Never immerse the unit, and avoid any area where standing water might 
accumulate. Mounting should be in the driest location available. The Inverter must be shielded from outside weather conditions.

• Leave a minimum of 2" clearance at front and back of the Inverter for proper ventilation. To avoid automatic Inverter shutdown due 

to excessive heat, any compartment that contains the Inverter must be properly ventilated with adequate outside air flow. The heavier 
the load of connected equipment, the more heat will be generated by the unit.

• Do not install the Inverter directly near magnetic storage media, as this may result in data corruption.

• Do not install the Inverter near flammable materials, fuel or chemicals.

Battery Connection Warnings

• The Inverter will not operate until batteries are connected.

• Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.

• Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be 

installed (whether for a mobile or stationary application) in a “dead air” compartment. Ideally, any compartment would have some 
ventilation to outside air. 

• Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.

• Do not allow objects to contact the two DC input terminals. Do not short or bridge these terminals together. Serious personal injury 

or property damage could result.

Equipment Connection Warnings

Do not use a Tripp Lite Inverter in life support or healthcare applications where a malfunction or failure of a Tripp Lite
Inverter could cause failure of, or significantly alter the performance of, a life support device or medical equipment.

• You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the output of 

the Inverter.

• The main grounding lug should be connected to the vehicle chassis with an 8 AWG wire (minimum).

Operation Warnings

• Your Inverter does not require routine maintenance. Do not open the device for any reason. There are no user serviceable parts inside.

• Potentially lethal voltages exist within the Inverter as long as the battery is connected. During any service work, the battery supply 

should be disconnected.

• Do not connect or disconnect batteries while the Inverter is operating. Dangerous arcing may result. Operating Mode Switch should be

in the OFF position.

Important Safety Instructions

Caution: If your Inverter/Charger is mounted in a location that lacks proper ventilation, the surface of the metal
enclosure could become hot. Allow to cool before touching. If the Inverter/Charger must be installed in a 
location that lacks proper ventilation, mount the unit in such a way that the top of the metal enclosure will 
not be subjected to accidental contact during operation.

200702194 PowerVerter DC-AC Owner’s Manual CH.qxd  2/23/2007  4:02 PM  Page 2

Summary of Contents for DC-to-AC

Page 1: ...h Inverter designed as a mobile energy source for your vehicle PowerVerter Inverters efficiently convert DC battery power into 120V AC household power allowing you to use equipment you commonly use at...

Page 2: ...outside air Sparks may result during final battery connection Always observe proper polarity as batteries are connected Do not allow objects to contact the two DC input terminals Do not short or brid...

Page 3: ...ions Main Ground Lug properly grounds the Inverter to vehicle grounding system or to earth ground See Configuration section for instructions Multi Speed Cooling Fan quiet efficient fan prolongs equipm...

Page 4: ...es the electrical load When the unit detects a load it automatically turns on Users may choose the minimum load the Inverter will detect by adjusting the Battery Charge Conserver Dial see diagram Usin...

Page 5: ...hem off when the engine is started Tripp Lite makes a current limited cable assembly part 73 0977 for this purpose Connect the current limited cable s red wire to the ignition switch s Engine Run term...

Page 6: ...mine DC Battery Amps Required Divide the total wattage required from step 1 above by the battery voltage 12 to determine the DC amps required STEP3 EstimateBatteryAmp HoursRequired foroperationunsuppo...

Page 7: ...attery within your vehicle s electrical system In most vehicles the Inverter will be connected to one or more dedicated auxiliary house batteries which are isolated from the drive system to prevent po...

Page 8: ...t the service problem does not originate from a misreading of the instructions Also check that the circuit breaker s are not tripped 2 If the problem continues do not contact or return the Inverter to...

Reviews: