OPTIMIZE EFFICIENCY 

UPS efficiency is typically best 
at full load and decreases as the 
load decreases. Operating at less 
than 100% load is recommended 
to avoid overloads caused by 
fluctuating power requirements, 
but the load is often far below 
recommended levels simply 
because it hasn’t been optimized. Tripp Lite offers several 
tools to help you safely right‑size load levels and balance fault 
tolerance and efficiency. Metered, Monitored and Switched PDUs 
include load meters that allow you to monitor load levels on‑site. 
Monitored and Switched PDUs also include a network interface 
that allows you to monitor load levels remotely. The optional 
SNMPWEBCARD accessory adds the same capability to any 
SmartOnline UPS System. 

SmartOnline UPS

Legacy UPS 

100%

85%

70%

 

SmartOnline 
Extreme 
Efficiency
Advantage 

LOAD 

EFFICIENCY 

50%

75%

100%

Higher efficiency means lower utility bills. SmartOnline UPS Systems  

can save over $20,000 per year for each 160kVA load they support. 

This estimate compares a SmartOnline UPS System operating at 97% efficiency in Economy 
Mode to a traditional on-line UPS system operating at 87% efficiency. The calculations assume 
a 24x7 duty cycle and U.S. average commercial electricity cost of $.1028 per kilowatt-hour, as 
reported by the Department of Energy. Savings vary with application and actual electricity cost. 

Efficiency Comparison

DATA CENTER SOLUTIONS  

SAVE ENERGY &  
REDUCE OPERATING COSTS 

Replacing traditional on‑line UPS systems with high‑efficiency 
SmartOnline UPS Systems will make your data center cooler, 
greener and more cost‑effective. All UPS systems are less than 
100% efficient because part of the electricity drawn by the UPS 
is lost as radiated heat before it reaches your equipment. The 
heat also requires cooling systems to work harder, consuming an 
additional ½ watt of cooling for each watt lost by the UPS.* 

Tripp Lite’s SmartOnline UPS Systems have good overall 
efficiency and offer an Economy Mode setting that delivers 

even  better  efficiency.  SmartOnline  UPS  Systems  are  up  to  97% 

efficient in Economy Mode, a potential increase of 10% or more 
versus traditional on‑line UPS systems. Replacing 160kVA of 
traditional UPS capacity with SmartOnline UPS Systems can 
save more than $20,000 per year. You’ll also reduce your facility’s 
CO

2

 emissions by 136 tons (enough to offset more than 2,000 

flights from New York to Washington) and conserve more than  
200 megawatt‑hours of electricity (enough to power 18 typical  
U.S. homes).

** 

*

 Reported by Gartner, IBM, Intel and other sources. 

**

 Based on U.S. average residential electricity 

consumption of 936kWh per month, as reported by the Department of Energy.

6

SmartOnline

 

Intelligent True On-Line UPS Systems  

SmartOnline Modular 3-Phase UPS

SmartOnline Hot-Swappable UPS

SmartOnline UPS

•  750VA – 160kVA    
•  Up to 97% Efficiency    
•  True On-Line Operation    
•  Pure Sine Wave Output    
•  Free PowerAlert Network  
  Management System    
•  Ideal Protection for Critical Systems  

Summary of Contents for ECO-UPS

Page 1: ...otect the Planet Save Energy Save Money Protect the Planet Save Energy Save Money Protect the Planet Save Energy Save Money Prote the Planet Save Energy Save Money Protect the Planet Save Energy Save...

Page 2: ...phone jacks protect telephones fax machines analog modems DSL modems and other communications equipment Select models include an illuminated LCD status screen that displays voltage wattage runtime an...

Page 3: ...USB connection required via included cable B BATTERY BACKUP OUTLETS Protect equipment from blackouts surges and line noise Remain on while AC power or battery backup power is available C SURGE ONLY O...

Page 4: ...routers PROTECT COMPUTERS AUDIO VIDEO EQUIPMENT Designed for home and office applications ECO Surge Suppressors protect your computers and electronics from damage and interference caused by power prob...

Page 5: ...itch Switches between energy saving mode Auto and standard mode Manual E Protected LED Indicates whether surge protection is functioning F Grounded LED Indicates whether the wall outlet is grounded G...

Page 6: ...TA CENTER SOLUTIONS SAVE ENERGY REDUCE OPERATING COSTS Replacing traditional on line UPS systems with high efficiency SmartOnline UPS Systems will make your data center cooler greener and more cost ef...

Page 7: ...alization VoIP cloud computing computer room network closet generator backup and other applications True on line double conversion operation delivers precision regulated pure sine wave output power is...

Page 8: ...tripplite com 201103209 95 3224 ABOUT TRIPP LITE Since 1922 Tripp Lite has established a global reputation for quality manufacturing superior value and excellent service Tripp Lite makes more than 3 0...

Reviews: