Provide 100% Availability with Hot-Swappable Modular Design
Adapt to Rack/
Tower/Stack
Applications
Adapt all models from
rackmount to tower or stacking
applications.*
• Removable rack hardware
• Optional base stands
Display Critical Operational Conditions
SmartOnline Rackmount/Tower UPS Systems feature a front panel LED display or combination LCD/LED
display which shows a variety of UPS operational modes and conditions. This interface provides more
information than comparable models, allowing you to react more rapidly to an alert before your systems
are put at risk.
LED Display
— Batte
r
y & Load Conditions:
The Load and
Battery Active Meters allow you to monitor the percentage levels
(25% - 100%) of two conditions: 1) battery charge as equipment
is supported by the UPS system during a blackout, and 2) the total
amount of the UPS system's capacity that the equipment load is
utilizing under normal operating conditions.
Fault/Wa
r
ning & UPS System Ope
r
ational Conditions:
LED set
alerts you to several fault conditions (including wiring faults in the
wall outlet) and warning conditions (including the need to recharge
or replace the UPS system's internal battery). It also indicates UPS
system operational status, including normal on-line operation,
bypass operation (due to fault or overload) or on-battery operation
(due to a blackout or severe brownout).
Combination LCD/LED Display
— LCD Display:
LCD Display lets
you access more precise information than provided by LEDs alone.
View over 45 separate fault/warning and UPS system operational
conditions including operational mode, alarm/shutdown conditions,
input/output voltage/frequency, battery voltage, load percentage
and more.
LED Display:
LED set is organized into a flow chart that
indicates UPS system operational status, including normal on-line
operation, bypass operation (due to fault or overload)
or on-battery operation (due to a blackout or severe brownout).
SU6000RT3U or SU10KRT3U tower mount
with optional base stands.
SU3000RTXL3U tower mount with
optional base stands.
1
2
3
4
1
2
3
4
* Optional base stands (model: 2-9USTAND) are
available to adapt any combination of models,
from 2U to 9U wide, to tower mounting.
All SmartOnline Rackmount/Tower UPS Systems include an automatic internal bypass that ensures 100% availability of connected
equipment by passing through utility power in the event of an internal fault or overload. Hot-Swappable Modular models include two
additional features that ensure continuous availability: an external maintenance bypass switch and a modular design. When the external
switch is set to "bypass", the UPS module can be removed for maintenance while the detachable PDU module remains installed,
continuing to power connected equipment as long as utility power is present.
Hot-Swap the UPS Module . . .
. . . PDU Module Continues Powering Equipment