10
Optional
Input
Communication Ports
Power
Output
Backup Time
External
Voltage
Nominal
"Smart" Contact
Cord
Capacity
(Typical Minutes) Battery
Rack
Range/
Output
AC Receptacles
RS-232
Closure
Input Plug
Length
Model
(VA/Watts) Half/Full Load
(B)
Packs
Space
Frequency (Hz)
Voltage
Quantity
NEMA Type
USB
(DB9)
(DB9)
(NEMA)
(ft)
UPS Systems
SU750RTXL2U
750/
11/4+
2U
65-138
120 (100/
6
5-15R
(D)(E)
1
1
(F)
—
5-15P
10
600
(50/60)
(C)
110/120)
SU1000RTXL2Ua
1000/
14/4.5+
2U
65-138 120
(100/
6
5-15R
(D)(E)
1
1
(F)
—
5-15P
10
800
(50/60)
(C)
110/120)
SU1500RTXL2Ua
1500/
17/5+
2U
65-138 120
(100/
6
5-15R
(D)(E)
1
1
(F)
—
5-15P
10
1200
(50/60)
(C)
110/120)
SU2200RTXL2Ua
2200/
14/4.5+
2U
65-138 120 7
6
(5-15/20R),
1
1
(F)
—
5-20P
(G)
10
1600
(50/60)
(C)
(110/120)
1 (L5-20R)
(D)(E)
SU3000RTXL3U
3000/
14/5+
3U
65-138
120 9
4
(5-15R),
1
1
(F)
—
L5-30P
10
2400
(50/60)
(C)
(110/120) 4
(5-15/20R),
1 (L5-30R)
(D)(E)
SU3000RTXR3U
3000/
33/14+
3U
65-138
120
9
4 (5-15R),
1
1
(F)
—
L5-30P
10
2400
(50/60)
(C)
(110/120)
4 (5-15/20R),
1 (L5-30R)
(D)(E)
SU3000RTXL3UHV
3000/
17/6+
3U
160-275
208/240
8
6 (6-15/20R),
—
1
(F)
—
L6-20P
10
2400
(50/60)
(C)
2 (L6-20R)
(D)
SU5000RT4U
5000/
17/8+
4U
65-140 (60)
208/240 &
12
8 (5-15/20R),
1
1
(F)
—
L14-30P
10
3800
(L-N)
120
2 (L6-20R),
(split phase
2 (L6-30R)
4 wire)
SU5000RT3U
5000/
20/8+
3U (power
156-276
208 & 120
16
2 (L6-20R),
—
1
1
L6-30P
10
3500
module), (50/60)
(C)
2 (L6-30R),
2U (battery
12 (5-15/20R)
module) & 2U
(transformer
module)
SU5000RT3UHV
(A)
5000/
20/8+
3U (power
156-276
208/240
4
2 (L6-20R),
—
1
1
L6-30P
10
3500
module) &
(50/60)
(C)
2 (L6-30R)
2U (battery
module)
SU6000RT4U
6000/
24/9+
4U
65-140 (60)
208/240
12
8 (5-15/20R),
1
1
(F)
—
L14-30P
10
4200
(L-N)
& 120
2 (L6-20R),
(split phase
2 (L6-30R)
4 wire)
SU6000RT3U
6000/
37/15+
3U (power
156-276
208/240
hardwire
(H)
—
1
1
hardwire
(I)
4200
module), 3U
(50/60)
(C)
& 120
(battery module)
& 3U (transformer
module)
SU6000RT3UHV
6000/
37/15+
3U (power
156-276
208/240
hardwire
(J)
—
1
1
hardwire
(K)
4200
module) &
(50/60)
(C)
3U (battery
module)
SU8000RT4U
8000/
12/5+
4U
65-140 (60)
208/240
8
4 (5-15/20R),
1
1
(F)
—
hardwire
5600
(L-N)
& 120
2 (L6-20R),
(split phase
2 (L6-30R)
4 wire)
plus hardwire
SU8000RT3U
8000/
15/6+
3U (power
156-276
208/240
6
4 (L6-20R),
—
1
1
hardwire
6400
module) &
(50/60)
(C)
2 (L6-30R)
3U (battery module)
SU8000RT3U1TF
8000/
15/6+
3U (power
156-276
208 & 120
18
4 (L6-20R),
—
1
1
hardwire
6400
module), 3U
(50/60)
(C)
2 (L6-30R),
(battery module)
12 (5-15/20R)
& 2U (transformer
module)
SU8000RT3UHW
8000/
15/6+
3U (power
156-276
208/240
hardwire
—
1
1
hardwire
6400
module) &
(50/60)
(C)
3U (battery
module)
SU10000RT3U
10000/
10/4+
3U (power
156-276
208/240
6
4 (L6-20R),
—
1
1
hardwire
8000
module) &
(50/60)
(C)
2 (L6-30R)
3U (battery
module)
SU10000RT3U2TF
10000/
10/4+
3U (power
156-276
208 & 120
18
4 (L6-20R),
—
1
1
hardwire
8000
module), 3U (battery
(50/60)
(C)
2 (L6-30R),
module) & 4U
12 (5-15/20R)
(2 transformer
modules)
SU10KRT3UHV
10000/
10/4+
3U (power
156-276
208/240
hardwire
—
1
1
hardwire
8000
module) & 3U
(50/60)
(C)
(battery module)
SU10KRT3U
10000/
10/4+
3U (power module),
156-276
208/240
hardwire
—
1
1
hardwire
8000
3U (battery module)
(50/60)
(C)
& 120
& 3U (transformer
module)
SU16000RT4U
16000/
12/5+
4U (power
100-140 (60)
208/240
13
5 (5-15/20R),
1
1
(F)
—
hardwire
11200
module) & 4U
(L-N)
& 120
2 (L6-30R),
(4 wire)
(battery module)
6 (C19)
SU16000RT4UHW
16000/
12/5+
4U (power
100-140 (60)
208/240
hardwire
1
1
(F)
—
hardwire
11200
module) & 4U
(L-N)
& 120
(4 wire)
(battery module)
G
Specifications
Complete, up-to-date specifications (including product weight and dimensions) available at www.tripplite.com
Also available: interactive UPS System selector guide, extended warranties, owner's manuals and more!
C
US
UL
US
C
E F
G
I
G
E F
E F
C D
C D
A B
A B
H
H
I
I
I
I
I
I
I
I
I
I
(L)