background image

2

Safety

IMPORTANT SAFETY INSTRUCTIONS.
SAVE THESE  INSTRUCTIONS.

This manual contains instructions and warnings that should be followed during the installation and operation of all Tripp Lite
Power Centers. Failure to heed these warnings will void your warranty.

• The Power Center features an internal protection that will disconnect the surge-protective component at the end of its

useful life but will maintain power to the load—now unprotected.

• Do not connect the Power Center to an ungrounded outlet. Do not use with 2-wire extension cords or adapters. Do not plug

extension cords into the Power Center.

• The Power Center is designed for indoor use only. Install the Power Center away from heat-emitting appliances such as

radiators or heat registers. Do not install where excessive moisture is present.

• Never install electrical wiring during a lightning storm.

• Do not drill into any part of the housing or open the housing for any reason. There are no user-serviceable parts inside.

Features

K

F

G

H

I

J

A

B

C

D

E

Switch & Cord Panel

Outlet Panel

Switch & Cord Panel

Detachable Power Cord with Right-Angle Plug:

connects the Power Center to a standard 3-wire grounded 120V AC

60Hz wall outlet. Detachable cord simplifies installation; right-angle plug permits equipment and furniture to be placed
flush against the wall.

Circuit Breaker:

protects against dangerous system overload. If the total load on the Power Center’s outlets exceeds 12

amps, the circuit breaker will trip and power will be turned off at the outlets. Reduce the load by unplugging some
devices. Depress the circuit breaker to restore power.

Remote AC/DC Control Jack:

allows remote on/off control when connected to an external component's “AC/DC Out”

jack with user-supplied cable. The Power Center's Power Switch must be set to “OFF” for the remote control function
to work. The connected external component's remote control output voltage should be between 3V and 30V AC or DC.

Illuminated Power Switch:

turns power on and off at the outlets. 

Mounting Flange:

allows for secure mounting (with user-supplied screws) on any suitable surface, including on a wall

behind a flat panel TV screen. The user must determine the fitness of the mounting surface and the user-supplied screws
prior to installation.

Outlet Panel

“HDTV” Outlet:

protects any flat panel TV (plasma, LCD or HDTV) against surge damage and line noise distortion on

the AC line. Turn power on and off at this outlet with the Power Switch. 

“ACCESSORY” Outlet:

protects any accessory (receiver, player, etc.) against surge damage and line noise distortion

on the AC line. Turn power on and off at this outlet with the Power Switch. 

“LINE OK” LED:

indicates that nominal AC power is present with no wiring faults detected. When this LED is

illuminated, AC power is safe for connected equipment.

A

B

C

D

E

F

G

H

200610022 93-2631Owner’s Manual.qxd  11/8/2006  12:18 PM  Page 2

Summary of Contents for HT2210ISOCTR

Page 1: ...stomer Support 773 869 1234 www tripplite com High Definition HD Compatible W ARRANTY REGISTRATION register online today for a chance to win a FREE Tripp Lite product www tripplite com warranty Safety...

Page 2: ...st the wall Circuit Breaker protects against dangerous system overload If the total load on the Power Center s outlets exceeds 12 amps the circuit breaker will trip and power will be turned off at the...

Page 3: ...rior to installation Note If possible mount the Power Center so that its LEDs are visible STEP 2 Connect Your Power Center to the AC Power Line Attach the power cord to the Power Center then plug it i...

Page 4: ...ly wired and grounded outlet No extension cords or other electrical connections may be used The installation must comply with all applicable electrical and safety codes set forth by the National Elect...

Page 5: ...773 869 1234 www tripplite com isobar Centro de energ a para equipos de pantalla plana Modelo HT2210ISOCTR Manual del propietario Compatible y de alta definici n HD Seguridad 6 Caracter sticas 6 Insta...

Page 6: ...peligrosas sobrecargas del sistema Si la carga total en las salidas del centro de energ a para equipos de pantalla plana excede los 12 amperios el interruptor autom tico disparar y las salidas dejar n...

Page 7: ...que los LEDs queden visibles PASO 2 Conecte centro de energ a para equipos de pantalla plana a la l nea de corriente alterna Conecte el cord n de alimentaci n al centro de energ a para equipos de pant...

Page 8: ...La pol tica de Tripp Lite es el mejoramiento continuo Las especificaciones est n sujetas a cambio sin previo aviso LEA SU INSTRUCTIVO CONSULTE SUS CONDICIONES DE GARANT A POR PRODUCTO P LIZA DE GARAN...

Page 9: ...ripplite com isobar Distributeur d alimentation lectrique panneau plat Mod le HT2210ISOCTR Manuel du Propri taire Haute D finition Compatible HD S curit 10 Caract ristiques 10 Installation 11 Garantie...

Page 10: ...le mobilier au mur Disjoncteur prot g contre la surcharge dangereuse du syst me Si la charge aux prises du distributeur d alimentation lectrique panneau plat exc de 12 amps le disjoncteur int gr au c...

Page 11: ...panneau plat sur l alimentation de secteur Brancher le cordon le cordon d alimentation au distributeur d alimentation lectrique panneau plat puis dans une prise standard 3 fils mise la terre 120VCA 6...

Page 12: ...que correctement branch r sultant d une cause autre qu une transitoire de secteur Si l utilisateur satisfait aux exigences ci dessus Tripp Lite r parera ou remplacera la discr tion de Tripp Lite l qui...

Reviews: