2 year warranty, $100,000
connected equipment insurance
(USA & Canada only)
Specifications
OUTPUT
Frequency
compatibility
60 Hz
Output VA
525
Output watts
300
Output nominal
voltage
120V AC
Output voltage
regulation
LINE MODE: Passes sine wave line voltage from 100-141V to connected equipment unchanged
BATTERY MODE: PWM sine wave output 120V +/-5%
Output frequency
regulation
LINE MODE: Passes line frequency of 60Hz +/-10%
BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz
Outlet quantity / type
6 NEMA 5-15R output receptacles (3 with UPS and surge suppression / 3 with surge suppression only)
INPUT
UPS Input cord
length (ft.)
6 ft., 16 gauge
Recommended
Electrical Service
15A 120V
Maximum Input
Amps (A)
12
Maximum Input Watts
1440
Input connection type
NEMA 5-15P
Voltage compatibility
(VAC)
120
BATTERY
DC system voltage
(VDC)
12
Battery Access
User replaceable batteries are accessible via user accessible battery door
Full load runtime
3 minutes (450VA)
Half load runtime
10 minutes (250VA)
Typical battery
lifespan
3-6 years, depending on usage
Battery charge
2-4 hours to 90%
LEDS ALARMS & SWITCHES
Alarms
Two program audible alarm beeps at regular intervals to indicate battery backup operation. Continuous alarm tone
indicates the UPS is running on battery power and is nearly depleted. Alarm also sounds during self-test operation.
Switches
Power on/off switch
Front panel LEDs
2 LEDs indicate line power, battery power status
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
Conforms to IEEE 587 / ANSI C62.41 specifications