background image

Owner’s Manual

IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Replacement Battery Cartridge (R.B.C.)

1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support

Copyright © 2014 Tripp Lite. All rights reserved.

Congratulations! Your new long-lasting, high-performance Replacement Battery Cartridge (R.B.C.), properly selected, is designed to extend the life of 

your UPS system. All R.B.C.s are valve-regulated and employ spill-proof construction. No special handling is required. R.B.C. cases (constructed of either 

ABS plastic, styrene or polypropylene) are non-conductive and have a high resistance to shock, vibration, chemicals and heat. State-of-the-art design 
techniques and high quality plate production processes used to construct your R.B.C. provide a battery with an extremely high energy density and a 

superior power-to-volume and power-to-weight ratio. All R.B.C.s are certified to provide:

SAFETY

Read before attempting battery 

replacement! Important Safety Instructions! 

Save these instructions!

This manual contains important instructions 

and warnings that should be followed during 
the installation and operation of all Tripp Lite 

Replacement Battery Cartridges (R.B.C.s).

WARNING!

•  Follow the original UPS system manufacturer’s 

instructions and safety information thoroughly 

before attempting replacement.

•  To eliminate high voltage shock hazard, 

be sure the UPS system is turned off and 

the power cord is unplugged from the AC 
outlet prior to battery replacement. Some 

manufacturers permit “hot swap” battery 
replacement while the UPS system is 

powered. Consult your UPS system’s owner’s 

manual for guidance.

•  Do not dispose of batteries in a fire; they may 

explode.

•  Do not open or mutilate the battery. 

Chemicals released are harmful to the skin 

or eyes and may be toxic. Follow first-aid 

procedures for chemical burns in the event of 
exposure. Use appropriate protective clothing 

when handling a leaking battery.

•  A battery can present a risk of high current 

in the event of a short circuit. High discharge 

can lead to severe burns and/or the risk 

of fire. Observe the following precautions 

when working around high capacity storage 
batteries: 1) remove watches, rings or other 

metal objects that might come in contact with 

battery terminals; 2) use tools with insulated 
handles; 3) do not lay tools or metal parts on 

top of the battery or near the terminals.

BATTERY REPLACEMENT

After following the safety procedures listed 

above:

1) Disconnect UPS system from power source.

2) Open battery compartment.

3) Disconnect and recycle used batteries. 

Connect new Replacement Battery 

Cartridge(s). Note: in order to properly 

reconnect multiple batteries, first take note 

of battery position and cable connections (by 
drawing a sketch) before disconnection.

4) Close battery compartment.

UPS AND BATTERY RECYCLING

Please recycle Tripp Lite Products.  The batteries 
used in Tripp Lite products are sealed Lead-Acid 

batteries.  These batteries are highly recyclable. 
Please refer to your local codes for disposal 
requirements.

You can call Tripp Lite for recycling info at  

1-773-869-1234.

You can go the Tripp Lite Website for up-to-date 

information on recycling the batteries or any 

Tripp Lite product.  Please follow this link:   
http://www.tripplite.com/en/support/recycling-

program.cfm

ADDITIONAL RBC SELECTION

Tripp Lite provides a wide range of additional 

Replacement Battery Cartridges (R.B.C.s). 

Consult www.tripplite.com for the most popular 
battery recommendations. When making your 

selection, whether or not your manufacturer 
and/or UPS system model number is listed, it 

is prudent to verify the following information: 

battery voltage* [example, 12 V (Volts)]; battery 

capacity* when optimally charged [example, 7.2 

AH (Amp Hours)]; battery dimensions;** and 

battery quantity.***

* Usually marked on the battery.
** This is important because manufacturers sometimes 
change battery content without changing model numbers.
*** In multiple battery systems, manufacturers recommend 
that all batteries be replaced at the same time.

•  Compatibility with all UPS systems, when 

properly selected

•  Completely maintenance-free operation

•  Economical pricing
•  Rugged construction for long service life

•  High discharge rate with deep discharge 

recovery

•  Wide operating temperature range

Reviews: