ON/Standby Switch

This momentary switch controls power to the UPS receptacles.
Engage it momentarily and release it to toggle between the “ON”
mode (power ON at the UPS receptacles) and “Standby” mode
(power OFF at the UPS receptacles).

Mute/Test Switch

Use this momentary switch to do two things:

Silence the blackout alarm

Engage this switch and release it.  Note: when the battery is nearly
depleted, the alarm resumes (and cannot be silenced) to alert you
to immediately shut down connected equipment.

Test your UPS’s battery charge

Leave your connected equipment ON.  With your UPS plugged in
and completely turned ON, engage this switch; hold it there for 5
seconds and release it.  The UPS will momentarily switch to battery
to test its charge.  The “

XXX

” light will turn ON and the alarm may

sound if your UPS fails a self-test and/or the UPS battery is less
than fully charged.  Let the UPS charge for 12 hours and perform
a second self-test.  If the light continues to stay on, contact Tripp
Lite for service.  CAUTION: Do not unplug your UPS to test its
batteries.  This will remove safe electrical grounding and may
introduce a damaging surge into your network connections.

Indicator Lights

All Indicator Light descriptions apply when the UPS is plugged into a wall outlet
and turned ON.

This green light will shine 

constantly

 to indicate AC power is

available at the receptacles. It will 

flash

 to indicate AC power is not

available. (See “System Enable Switch” and “ON/Standby Switch”
descriptions above.)

This multi-colored light displays 7 separate UPS battery charge
conditions. It will turn from red (low) to yellow (medium) to green
(full) to show you the level of battery charge. If the light is constant,
then your UPS is operating from line power and the battery is
charging. If the light is flashing, then your UPS is operating from
battery power and the battery is discharging. When the light
flashes red, close any files you are working on and shut down your
computer.

Whenever your UPS is automatically correcting high or low AC line
voltage, this green light will turn ON and the UPS will gently click.
The more the UPS has to correct voltage, the more the green light
will turn ON and the more the UPS will click. These are both
normal, automatic operations of your UPS, and no action is
required on your part.

This red light will turn ON if your UPS fails a self-test and/or the
UPS battery is less than fully charged. Let the UPS charge for 12
hours and perform a second self-test. If the light continues to stay
on, contact Tripp Lite for service.

9811198  SmartPro NET & SmartPro XC Owners Manual.p65

5/17/00, 10:57 AM

5

Summary of Contents for SMART 1250XL NET

Page 1: ...th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com Owner s Manual SmartPro NET SmartPro XL 1250 3000 VA Intelligent Network UPS Systems 120V ESPAÑOL p 8 FRANÇAIS p 15 Installation p 3 4 Basic Operation p 4 6 Storage Service p 7 Specifications p 7 Safety p 2 Warranty Insurance p 6 ...

Page 2: ...antly alter the performance of a life support device Do not connect surge suppressors or extension cords to the output of your UPS This might damage your UPS and will void both the surge suppressor and UPS warranties Battery Warnings Your UPS does not require routine maintenance Do not open your UPS except to replace batteries There are no user serviceable parts inside Battery replacement should b...

Page 3: ...he battery charger and microprocessor The XXX light will flash until you engage the ON Standby Switch to activate the ON mode Engage the momentary ON Standby Switch UPS front panel and release it to activate the ON mode and supply power to the UPS receptacles See Figure 2 3 2 1 DB9 Port Connection Optional On Next Page Figure 2 ON Standby Switch Figure 1 DIP Switch 4 System Enable Switch ENABLE DI...

Page 4: ...232 communications If you have additional computers Connect them to the DB9 ports labeled BASIC which provide basic contact closure shutdown capabili ties Set their corresponding LAN Interface DIP Switches to the ACTIVATE DOWN position See diagram for which switch controls which port Serial port connections are optional Your UPS will function properly without these connections The SMART DB9 port i...

Page 5: ...icator Lights All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned ON This green light will shine constantly to indicate AC power is available at the receptacles It will flash to indicate AC power is not available See System Enable Switch and ON Standby Switch descriptions above This multi colored light displays 7 separate UPS battery charge conditions It wi...

Page 6: ... port connects your UPS to any workstation or server Use with Tripp Lite software and 73 0743 cable to monitor and manage network power and automatically save open files and shut down equipment during a blackout This port uses RS 232 com munications to transmit UPS and power conditions Pin 7 Transmit Pin 8 Common Pin 9 Receive Contact Tripp Lite Customer Support for more information and a list of ...

Page 7: ...toms of the problem If the UPS is within the 2 year warranty period enclose a copy of your sales receipt SMART 2200 NET SMART 3000 NET Output Capacity VA Watts 2200 1700 3000 2400 Battery Runtime Half Load Full Load Minutes 27 11 23 7 Battery Recharge Rate 2 4 hrs 2 4 hrs Suggested Circuit 15 amp or 20 amp dedicated 30 amp dedicated Approvals UL cUL UL cUL SMART 1250XL NET SMART 2200XL NET Output ...

Page 8: ...1111 W 35th Street Chicago IL 60609 USA 773 869 1234 USA 773 869 1212 International www tripplite com ...

Reviews: