6

Other UPS Features

AC Receptacles

The receptacles provide your connected equipment with AC line
power during normal operation and battery power during black-
outs and brownouts. They also protect your equipment against
damaging surges and line noise. You can remotely reboot con-
nected equipment by turning all of the receptacles OFF and ON
at once using Tripp Lite UPS software. Select models, however,
feature a unique “Remote Reboot Outlet” (identified on the back
panel of your UPS) which allows you to use Tripp Lite UPS software
to remotely reboot equipment connected to this outlet without
interrupting power to equipment connected to the other outlets.
See software instructions for details.

RS-232 Port

This port, labeled "LAN 4.1" on the UPS, connects your UPS to a
workstation or server. Use with Tripp Lite software and cabling to
monitor and manage network power and automatically save open
files and shut down equipment during a blackout. This port uses
RS-232 communications to transmit UPS and power conditions
(Pin 7 = Transmit; Pin 8 = Common; Pin 9 = Receive). Contact Tripp
Lite Customer Support for more information and a list of available
SNMP, network management and connectivity products.

Contact Closure Ports

These ports, labeled "LAN 2.2" on the UPS, are also used to
connect your UPS to a workstation or server. Use with Tripp Lite
software and cabling to automatically save open files and shut
down equipment during a blackout. This port uses contact-
closure signals to indicate line-fail and low-battery status.
Contact  Tripp Lite Customer Support for more information.

Note: constant power is available at the Remote Reboot Outlet (and all other outlets)
unless controlled through Tripp Lite UPS software.

Whenever your UPS is automatically correcting high or low AC
line voltage, this green light will turn ON and the UPS will gently
click. The more the UPS has to correct voltage, the more the
green light will turn ON and the more the UPS will click. These
are both normal, automatic operations of your UPS, and no action
is required on your part.

This red light will turn ON if your UPS fails a self-test and/or the
UPS battery is less than fully charged. Let the UPS charge for 12
hours and perform a second self-test. If the light continues to
stay on, contact Tripp Lite for service.

This multi-colored light displays 4 separate UPS load conditions.
It will turn from green (low) to yellow (medium) to red (high) as
you connect equipment to show you the load level your UPS is
supporting. When the light is red, your UPS is supporting a load
above 85% of its capacity. If the red light begins flashing, then
your UPS is severely overloaded. Remove overload immediately
until light stops flashing.

9905248 DON'T ARCHIVE!!! 2200-3000 VA 230V SmartPro OM.p65

6/20/00, 10:13 AM

6

Summary of Contents for Smart INT 2200

Page 1: ...Basic Operation p 5 7 Storage Service p 7 Specifications p 7 Safety p 2 Warranty Insurance p 6 1111W 35thStreet Chicago IL 60609 USA CustomerSupport 773 869 1234 www tripplite com Owner sManual Smart...

Page 2: ...ntly alter the performance of a life support device Do not connect surge suppressors to the output of your UPS This may damage your UPS and will void both the surge suppressor and UPS warranties Batte...

Page 3: ...youconnecthousehold appliances laser printers or surge suppressors Cords and receptacle adapters are available from TrippLitetoaccommodatemostoutletconfigurations If rewiring is necessary refer to the...

Page 4: ...computers Connect them to the DB9 ports labeled LAN 2 2 which provide basic contact closure shutdown capabilities using the black cables that came with your UPS Set their corresponding LAN Interface D...

Page 5: ...quipment ON With your UPS plugged in and completely turned ON engage this switch hold it there for 5 seconds and release it You will hear a series of short beeps as the UPS momentarily switches to bat...

Page 6: ...on the UPS are also used to connect your UPS to a workstation or server Use with Tripp Lite software and cabling to automatically save open files and shut down equipment during a blackout This port us...

Page 7: ...attery Runtime Half Load Full Load Minutes 27 11 23 7 Battery Recharge Time 2 4 hrs 2 4 hrs Approvals UL CE UL CE BatteryRuntimeforthismodelcanbeincreasedwiththeadditionofoptionalexternalbatterypacks...

Page 8: ...p 10 11 Operaci n b sica p 12 14 Almacenamiento y servicio p 14 Especificaciones p 14 Seguridad p 9 Warranty Insurance p 6 1111W 35thStreet Chicago IL 60609 USA DepartamentodeAsistenciaalCliente 773...

Page 9: ...mente el rendimiento del dispositivo de sustentaci n de la vida No conecte supresores de sobrevoltaje a la salida del UPS Si lo hace podr a causar da os al UPS y anular las garant as del supresor de s...

Page 10: ...S lo sobrecargar TrippLitetienedisponiblescablesyadaptadoresde recept culos que se ajustan a la mayor a de las configuraciones de salida Si es necesario volver a hacer las conexiones el ctricas consul...

Page 11: ...DB9 rotulados LAN 2 2 que proporcionan capacidades b sicas de apagado de cierre por contacto utilizando los cables negros que se incluyen con su UPS Coloque los conmutadores DIP de interfaz con LAN en...

Page 12: ...ga de la bater a del UPS Deje ENCENDIDO el equipo conectado Con el UPS enchufado y completamente ENCENDIDO embrague este conmutador mant ngalo en esa posici n durante 5 segundos y lib relo Escuchar un...

Page 13: ...nte de Tripp Lite si desea obtener m s informaci n y una lista de los productos SNMP de administraci n de redes y de conectividad que est n disponibles Puertos de cierre por contacto Estos puertos rot...

Page 14: ...11 23 7 Tiempo de recarga de la bater a 2 4 hr 2 4 hr Aprobaciones UL CE UL CE Eltiempodefuncionamientodelabater adeestemodelosepuedeaumentarconlaadici ndebloquesdebater asexternosopcionales Voltajede...

Page 15: ...curit p 16 Warranty Insurance p 6 1111W 35thStreet Chicago IL 60609 USA Assistanceclient le 773 869 1234 www tripplite com Manuel d utilisation SmartPro INT SmartPro XL INT 2 200 3 000 VA Syst mes d U...

Page 16: ...anne ou de compromettre sensiblement la performance d un appareil de maintien des fonctions vitales Ne branchez pas de limiteurs de surtension sur la sortie de votre UPS sous peine d endommager votre...

Page 17: ...mat riel informatique Vous surchargerez votre UPS si vousconnectezdesappareils lectrom nagers des imprimantes laser ou des limiteurs de surtension Descordonsetdesadaptateurssontdisponiblesaupr sde Tri...

Page 18: ...surent les fonctions d arr t de base par fermeture des contacts l aide des c bles noirs qui vous ont t fournis avec votre UPS R glez leurs commutateurs DIP d interface de r seau local correspondants s...

Page 19: ...se trouvant branch sur secteur et enti rement mis sous tension activez ce commutateur maintenez le dans cette position pendant 5 secondes puis rel chez le Vous entendrez une s rie de courts bips sono...

Page 20: ...tactez l assistance client le Tripp Lite pour obtenir de plus amples informa tions et la liste de sproduits SNMP de gestion de r seau et de connectivit disponibles Ports de fermeture des contacts Ces...

Page 21: ...charge pleine charge 27 11 23 7 Temps de recharge de la batterie 2 4 heures 2 4 heures Homologations UL CE UL CE L autonomiedelabatteriepourcemod lepeut treaugment eenajoutantdesblocs batteriesextern...

Page 22: ...allation S 24 25 Grundlegender Betrieb S 26 28 Lagerung und Kundendienst S 28 Technische Daten S 28 Sicherheit S 23 Warranty Insurance p 6 1111W 35thStreet Chicago IL 60609 USA Kundendienst 773 869 12...

Page 23: ...ife Support Systems bewirken k nnte Es darf keine berspannungsschutzeinrichtung an den Ausgang der USV angeschlossen werden Andernfalls k nnen Sch den an der USV verursacht werden wobei die Garantie d...

Page 24: ...schutzeinrichtungenverursachteine berlastungderUSV TrippLiteliefertKabelundSteckbuchsenadapterf rdie meistenSteckdosenkonfigurationen Wenneine Neuverdrahtung erforderlich ist beziehen Sie sich bitte a...

Page 25: ...hnittstelle gesteuert Wenn weitere Computer angeschlossen werden sollen Schlie en Sie diese ber die schwarzen Kabel der USV an die mit LAN 2 2 beschrifteten DB9 Ports an die ein grunds tzliches Aussch...

Page 26: ...SiediesenSchalterbeieingesteckter und vollst ndig EINGESCHALTETER USV halten Sie ihn f nf Sekunden lang und geben Sie ihn wieder frei Sie h ren eine Reihe von kurzen Signalt nen w hrend die USV kurzze...

Page 27: ...werden Kontaktschlie ungsports ber diese mit LAN 2 2 beschrifteten Ports wird die USV auch an die Workstation bzw den Server angeschlossen Verwenden Sie diese mit der Tripp Lite Software und Verkabel...

Page 28: ...nicht abgelaufen ist f gen Sie eine Kopie der Verkaufsbest tigung bei Smart INT 2200 Smart INT 3000 Ausgangskapazit t VA Watt 2200 1700 3000 2400 Batterie Laufzeit Halbe Last Volle Last in Minuten 27...

Reviews: