background image

4 NEMA 5-15R outlets deliver battery backup for devices that require constant power

All 8 outlets protect against surges or spikes that can harm equipment or data

Automatic Voltage Regulation (AVR)

Maintains 120V nominal output over input range of 89V–139V without using battery power

Rotatable LCD Status Screen

Large LCD screen shows real-time input voltage, overload, AVR and battery statuses

Rotates for easy viewing in both horizontal and vertical installations

AC Line, Coaxial and Tel/DSL Surge Suppression

1038-joule surge suppression rating protects connected equipment and data from harmful power surges

Tel/DSL RJ11 jacks (with included cable) protect standard dialup/DSL connection

2.2 Hz coaxial jacks protect CATV, broadband cable internet, satellite or broadcast antenna connections

EMI/RFI Line Noise Filtering

Removes electromagnetic and radio frequency interference that can disrupt or damage equipment’s performance

USB Ports

HID-compliant USB port (when used with free PowerAlert software) enables safe unattended system shutdown and file saves in the event of a prolonged

power failure

Front-panel USB port delivers 2.1A for fast charging of smartphones and tablets

ENERGY STAR Certification

Saves you money, saves energy and protects the environment by meeting strict EPA efficiency guidelines

Flexible Installation Options

Space-saving NEMA 5-15P right-angle plug with 6 ft. cord

Adapts to vertical or horizontal installation without special hardware

Specifications

OUTPUT

Output Volt Amp Capacity (VA)

1000

Output Watt Capacity (Watts)

500

Nominal Output Voltage(s)
Supported

115V; 120V

Frequency Compatibility

60 Hz

Output Voltage Regulation (Battery
Mode)

115V (+/- 5%)

Output Receptacles

(8) 5-15R

UPS Output Receptacles (Surge
Suppression Only)

4 UPS outlets, 4 surge-only outlets

2 / 5 

 

Summary of Contents for SMART1000LCDU

Page 1: ...regulation AVR maintains 120V nominal output over an input range of 89V to 139V without using battery power EMI RFI noise filtering improves your equipment s performance and prevents damage A 1038 joule surge suppression rating protects your equipment from harmful power surges With Tripp Lite s free PowerAlert software available via web download the SMART1000LCDU enables safe unattended system shu...

Page 2: ...EMI RFI Line Noise Filtering Removes electromagnetic and radio frequency interference that can disrupt or damage equipment s performance USB Ports HID compliant USB port when used with free PowerAlert software enables safe unattended system shutdown and file saves in the event of a prolonged power failure Front panel USB port delivers 2 1A for fast charging of smartphones and tablets ENERGY STAR C...

Page 3: ...le batteries Expandable Runtime No VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation AVR maintains line power operation with input voltage as low as 89 Undervoltage Correction Input voltages between 89 and 104 are boosted by 14 USER INTERFACE ALERTS CONTROLS Front Panel LCD Display Backlighted LCD screen indicates input voltage 5 bar battery charge level overload AVR o...

Page 4: ...g 7 05 UPS Shipping Dimensions hwd in 10 43 x 15 55 x 4 8 UPS Shipping Dimensions hwd cm 26 5 x 39 5 x 12 2 Shipping Weight lbs 16 2 Shipping Weight kg 7 4 UPS Housing Material ABS Primary UPS Height mm 301 Primary UPS Width mm 93 Primary UPS Depth mm 184 Shipping Height mm 265 Shipping Width mm 395 Shipping Depth mm 122 ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit 0 to 4...

Page 5: ...iciency GREEN UPS CERTIFICATIONS UPS Certifications ENERGY STAR Qualified Meets FCC Part 15 Category B EMI Tested to CSA Canada Tested to NOM Mexico Tested to UL1778 USA WARRANTY Product Warranty Period U S Canada 3 year limited warranty Product Warranty Period Latin America 3 year limited warranty Product Warranty Period International 2 year limited warranty Product Warranty Period Mexico 3 year ...

Reviews: