Important Safety Instructions

3

Equipment Connection Warnings

•  Use of this equipment in life support applications where failure of this equipment can 

reasonably be expected to cause the failure of the life support equipment or to significantly 
affect its safety or effectiveness is not recommended. 

•  Do not connect surge protectors or extension cords to the output of your UPS. This might 

damage the UPS and may affect the surge protectors and UPS warranties.

•  Connect the UPS to an outlet that is adequately protected against excess currents, short 

circuits and earth faults as part of the building installation.

Battery Warnings

•  Your UPS does not require routine maintenance. Do not open your UPS for any reason. 

There are no user-serviceable parts inside.

•  Batteries can present a risk of electrical shock, chemical hazard and burn from high short-

circuit current. Observe proper precautions. Do not dispose of the batteries in a fire. Do 

not open the  
UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug and 

turn off the UPS before performing battery replacement. Use tools with insulated handles. 

There are no user-serviceable parts inside the UPS. Battery replacement should be 

performed only by authorized service personnel using the same number and type of 

batteries (Sealed Lead-Acid). The batteries are recyclable. Refer to your local codes for 
disposal requirements or visit http://www.tripplite.com/support/recycling-program for 

recycling information. Tripp Lite offers a complete line of UPS System Replacement  

Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at  

http://www.tripplite.com/products/battery-finder/ to locate the specific 

replacement battery for your UPS.

• When adding an external battery pack, connect only a Tripp Lite recommended battery pack 

of the correct voltage and type. Do not connect or disconnect the external battery pack 

when the UPS is operating on battery power. Visit Tripp Lite on the Web at  

www.tripplite.com/support to locate the specific battery for your UPS.

UPS and Battery Recycling

Please recycle Tripp Lite Products. The batteries used in Tripp Lite products are 

sealed Lead-Acid batteries.  These batteries are highly recyclable. Please refer to 
your local codes for disposal requirements.
You can call Tripp Lite for recycling info at 1.773.869.1234.
You can go to the Tripp Lite Website for up-to-date information on recycling the 

batteries or any Tripp Lite product. Please follow this link:   
http://www.tripplite.com/support/recycling-program/

17-02-143-9336B5.indb   3

3/14/2017   2:03:49 PM

Summary of Contents for SMART1200LCD

Page 1: ...Features 8 Battery Replacement 9 Storage and Service 11 Product Registration 11 Español 13 Français 25 SMART1500LCD Series Number AG 8869 SMART1500LCDXL Series Number AGSM8191 Not suitable for mobile applications 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2017 Tripp Lite All rights reserved PROTECT YOUR INVESTMENT Register your product for quicker service and ultim...

Page 2: ...d under warranty UPS Connection Warnings Connect your UPS directly to a properly grounded AC power outlet Do not plug the UPS into itself this will damage the UPS Do not modify the UPS s plug and do not use an adapter that would eliminate the UPS s ground connection Do not use extension cords to connect the UPS to an AC outlet If the UPS receives power from a motor powered AC generator the generat...

Page 3: ... Battery replacement should be performed only by authorized service personnel using the same number and type of batteries Sealed Lead Acid The batteries are recyclable Refer to your local codes for disposal requirements or visit http www tripplite com support recycling program for recycling information Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges R B C Visit Tripp...

Page 4: ...or the unit s battery will only be accessible after it has been charged for 24 hours STEP 3 Plug your equipment into the UPS Your UPS is designed to support electronic equipment only You will overload the UPS if the total VA ratings for all the equipment you connect to the outlets exceeds the UPS s Output Capacity To find your equipment s VA ratings look on their nameplates If the equipment is lis...

Page 5: ...all tool in the slots on the sides of the display to pop it out of the UPS housing rotate the display and snap it back into the UPS housing LCD Features Tap the MODE button to advance from one display to the next Use the MUTE button to toggle settings for Power Sensitivity Control External Battery Setting Control Scroll Control Alarm LCD Brightness and Self test functions The last option displayed...

Page 6: ...last option displayed before navigating away from this menu option will be the selected setting This setting is normally set to 100 which enables the UPS to protect against waveform distortions in its AC input When such distortion occurs the UPS will normally switch to providing PWM sine wave power from its battery reserves for as long as the distortion is present In some areas with poor utility p...

Page 7: ...XL model only Tap the MODE button repeatedly to advance to the External Battery screen as shown here Press the MUTE button to advance to the next available option The last option displayed before navigating away from this menu option will be the selected setting Note The Battery Runtime calculation is based on this setting This feature setting allows the user to configure the UPS for use with an E...

Page 8: ...REE download at www tripplite com and appropriate USB or DB9 cable Both a USB and a DB9 cable are included with your UPS Notes 1 This connection is optional The UPS will work properly without this connection 2 This UPS System provides basic communication compatibility with most integrated Windows Macintosh and Linux power management applications Battery Backup Protected Surge Protected Outlets Pro...

Page 9: ...tery cartridge For the SMART1500LCDXL model only Tripp Lite BP24V15RT2U external battery pack rated 24Vdc 14Ahr with overcurrent protection should be connected to the external battery pack connector For further information about replacement compatibility and ordering visit Tripp Lite on the Web at http www tripplite com products battery finder To Replace the Batteries 1 Remove the retaining screw ...

Page 10: ... place the new batteries into the UPS and connect the positive red connectors and negative black connectors 5 Reattach the bottom panel and secure using the retaining screw removed in step 1 17 02 143 9336B5 indb 10 3 14 2017 2 04 00 PM ...

Page 11: ...ducts shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid Mark the RMA number on the outside of the package If the product is within its warranty period enclose a copy of your sales receipt Return the product for service using an insured carrier to the address given to you when you request the RMA Visit www tripplite com warranty today to regis...

Page 12: ... Technical Requirements Document s The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that the compliance ...

Reviews: