Supports timed inverter shutoff after unattended shutdown, activate self-test and UPS output power control for delayed or immediate reboot
of connected equipment
Supports Tripp Lite's WatchDog software application to restore unresponsive programs by systematically restarting applications, operating
systems and ultimately rebooting completely locked computers by momentarily switching UPS power off and back on again (requires
optional WATCHDOGSW)
Status LEDs offer continuous status information of UPS operating parameters and site power quality
Hot-swappable batteries allow on-site battery replacement without powering off connected equipment
Single line TEL/DSL and network Ethernet line surge suppression
Specifications
OUTPUT
Output Volt Amp Capacity
(VA)
750
Output Watt Capacity
(watts)
500
Output power factor
0.7
Nominal Output
Voltage(s) Supported
100V; 110V; 120V
Nominal Voltage details
120V default (voltage selection via back panel switches)
Frequency compatibility
50 / 60 Hz
Output voltage regulation
(line mode)
-13%, +15%
Output voltage regulation
(Battery mode)
+/- 5%
Built-in UPS output
receptacles
8 5-15R outlet(s)
Surge suppression only
outlets
4 UPS outlets, 4 surge-only outlets
Output AC waveform (AC
mode)
Sine wave
Output AC waveform
(battery mode)
Pure Sine wave
INPUT
Rated input current (at
maximum load)
12A
Nominal Input Voltage(s)
Supported
100V AC; 110V AC; 120V AC
UPS input connection
type
5-15P
UPS Input cord length (ft.)
6
UPS Input cord length (m)
1.8
Recommended Electrical
Service
15A 120V
Phase
Single-Phase
BATTERY