10 – Specifications

11 – Storage and Service

Input

 Voltage Range

Up to 160-280/277-485V AC (3Ø, 4-Wire + Ground, Wye)  
(160-176/277-305V AC at Load < 75%)

 Frequency Range

45 to 65 Hz

 Power Factor 

Up to 0.99 at 100% Linear Load

Output

 Voltage Range

User-Selectable 200/220/230/240V AC (1Ø, 2-Wire + Ground)

 Voltage Adjustment 

±0%; ±1%; ±2%; ±3%

 Voltage Regulation 

±2%

 Capacity 

10 kVA / 7 kW

 Rated Power Factor 

0.8 Lagging 

 Wave Form 

Pure Sine Wave, THD <3%

 Frequency Stability 

±0.2% (Free-Running)

 Frequency Regulation 

±1%; ±3%

 Transfer Time to Battery

0 ms

 Crest Factor 

3:1 Acceptable

 Efficiency (AC to AC, Normal Mode) 

Up to 91%

 Efficiency (AC to AC, Economy Mode)

Up to 93%

 Estimated Full Load Runtime

 5 minutes

 Estimated Half Load Runtime

 14 minutes

Physical

Dimensions (H x W x D)

135 x 440 x 680 mm (Power Module)

Input/Output Connection

Hardwire

Unit Weight

28 kg (Power Module)

Storage

First turn the UPS system’s output and utility input breaker OFF, then disconnect the UPS system’s input from the AC utility power source. 
Next, disconnect all equipment. The UPS system must be stored in a clean, secure environment with a temperature less than 40° C and a 
relative humidity less than 90% (non-condensing). 

Note: If the UPS system remains off for an extended period of time, it should be turned 

on periodically to allow the batteries to recharge. The UPS system should be turned on and the batteries should be recharged at least one 
uninterrupted 12-hour period every three months in moderate-temperature environments (-15° to 30° C), or every two months in high-
temperature environments (30° to 40° C). Failure to recharge the batteries periodically may cause irreversible battery damage.

Service

The UPS system is covered by the limited warranty described in this manual. Extended and on-site warranty options are also available. For more 
information, call Tripp Lite Customer Service at +1.773.869.1234. If returning the UPS system to Tripp Lite, carefully pack the UPS system using 
the original packing material that came with the unit. Enclose a letter describing the symptoms of the problem. If the UPS system is within the 
warranty period, enclose a copy of the sales receipt.

Summary of Contents for SmartOnline SU10KRT1X

Page 1: ...Mounting 5 4 1 Unpacking 5 4 2 Placement 6 4 3 Mounting Rack 6 4 4 Mounting Tower 7 5 Wiring 8 5 1 Wiring Preparation 8 5 2 Terminal Block Diagram 8 5 3 Electrical and Cable Data 8 5 4 AC Input Output...

Page 2: ...tilation openings of the UPS system or otherwise impede the airflow from the front to the rear of the UPS system Do not place any object on the UPS system especially containers of liquid Spilling liqu...

Page 3: ...damage the UPS system and create a risk of personal injury and property damage Wiring should be performed by trained qualified electricians only Battery Warnings Allow batteries to charge uninterrupt...

Page 4: ...Note Remove the network card in order to use the RS 232 port B Settings Switch for Parallel Redundancy Operation C CAN Bus Connection Ports for Parallel Redundancy Operation D Cooling Fans E External...

Page 5: ...unit Inspect the unit carefully prior to installation If anything appears to be damaged contact Tripp Lite for service Retain the packing materials for future use Packing List 1 UPS Power Module 1 Ext...

Page 6: ...tact the manufacturer of the rack or rack enclosure for a solution 4 Post Mounting Procedure Note The mounting procedure is identical for the external battery pack and the UPS power module Mount the e...

Page 7: ...ition Pull the panel out slightly rotate it and push it back into place Tower Mounting Procedure 1 Use M4 flat head screws S2 to attach covers A5 to four of the tower feet A4 2 Use M3 flat head screws...

Page 8: ...y pack Mark all cables according to their correct purpose polarity phase and diameter Review the diagram in Section 5 2 to familiarize yourself with the terminal block Consult the table in Section 5 3...

Page 9: ...eves through the knockouts in the terminal block cover A2 Each input output wire should terminate with a ring terminal 3 Connect the ring terminal for each input output cable to the appropriate input...

Page 10: ...system 1 Switch the external battery pack s DC breaker to the OFF position 2 Remove the terminal covers from the UPS power module s external battery pack DC cable connector and the external battery pa...

Page 11: ...in economy mode 6 Fault LED This red LED illuminates when UPS system experiences a fault or other abnormal condition If the condition persists after restarting the UPS system refer to Section 9 Troubl...

Page 12: ...f temperature voltage amperage level percentage and frequency Indicates the category being measured line load battery EPO Emergency Power Off Code Description Er05 Battery Weak or Dead Er06 Output Sho...

Page 13: ...and the battery charger begins to charge the external battery pack 8 Press the ON button for approximately 3 seconds then release it The UPS will beep twice and the LCD screen will change from B to C...

Page 14: ...elapsed you will need to repeat the previous step 5 The UPS system will run a self test and display H again Battery mode startup is successful and connected equipment will operate until the battery i...

Page 15: ...tely three seconds until the buzzer sounds twice then release the buttons Except for buzzer Q1 Q2 and self test R1 R2 all other default settings may now be changed by pressing the Previous Change Sett...

Page 16: ...upply circuit is securely grounded Start up Procedure 1 Position the UPS systems as specified above 2 Connect the parallel communication cables C1 C2 to the Ring loop at a maximum length of 7 m Secure...

Page 17: ...rting the EPO terminals activates the EPO emergency power off function which provides emergency shutdown of the UPS system Note The network card must be removed in order to use the UPS system s RS 232...

Page 18: ...t LED Er16 Er27 All parallel UPS parameters except ID number must be same Adjust the parameters Fault LED Er21 Reconnect the RJ45 cable or set a UPS with ID 1 Fault LED Other Error Code Have a qualifi...

Page 19: ...tility power source Next disconnect all equipment The UPS system must be stored in a clean secure environment with a temperature less than 40 C and a relative humidity less than 90 non condensing Note...

Page 20: ...he batteries are designed for hot swap replacement i e replacement while the UPS system is in ON mode but some qualified service personnel may wish to put the UPS system in OFF mode and disconnect equ...

Page 21: ...cific legal rights and you may have other rights which vary from jurisdiction to jurisdiction Tripp Lite 1111 W 35th Street Chicago IL 60609 USA WARNING The individual user should take care to determi...

Reviews: