10 – Display and Configuration
(continued)
10-5-6 Control & Test Setup
(continued)
Manual Battery Test
Press ”
” to execute “MANUAL BAT TEST”. Allows you to
run a battery test at a non-scheduled time at the user’s discretion.
(This item is only accessible by the administrator! The password
will be needed.)
The duration of the test can be chosen using
Section 10-5-3
,
step 6.
Force Boost Charge
Press (
) to execute “FORCE BOOST CHARGE” Enables
activating the boost charge which is at a voltage of 5% higher than
the nominal setting.
Warning: Boosting battery charge rate for
extended periods may damage the battery system.
(This item is only accessible by the administrator! The password
will be needed.)
Clear Battery Test Result
Press “
” to execute “CLR BAT TEST RESULT”. This will
clear all battery test results in log.
Note: Clearing event logs may invalidate warranty claims. All
warranty claims must be accompanied by supporting event log
information.