Highlights
1500VA / 1.5kVA / 1350W on-line double-conversion 2U rack / tower UPS
100/110/120/127V 50/60Hz output; High efficiency economy mode option
Interactive LCD with 9 selectable screens of UPS and site power data
Expandable runtime, Hot-swap batteries, 18.5 in / 47cm depth
USB, RS232 & EPO ports, support for SNMP/WEB card option
2 independently switched load banks
NEMA 5-15P input; 6 NEMA 5-15R outlets
Description
Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters,
computer rooms and network closets. Online, double-conversion Uninterruptible Power Supply (UPS) maintains perfectly regulated output power by
continuously converting raw AC input to DC, then re-converting output back to AC. Fully regulated sine wave AC output with +/-2% voltage regulation
powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains
battery-derived AC output during power failures with zero transfer time. Extended runtime options available. Interactive LCD interface reports UPS
operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Highly efficient operation in
optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232,
contact-closure and optional SNMPWEBCARD network interface. Built-in DB9 port offers both enhanced RS-232 data and basic contact closure
monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and
Mac OS X. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. LED display reports UPS
operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. LED/LCD display
panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode LCD
configuration options. Programmable self-test. Fault-tolerant auto-bypass mode. Field-replaceable, hot-swappable internal batteries and external
battery packs.
Package Includes
SU1500RTXLCD2U UPS System
PowerAlert Software with USB, Serial & EPO cabling
4 post rackmount installation kit
Instruction manual
Features
Tripp Lite SU1500RTXLCD2U 1500VA / 1.5kVA / 1350W on-line, double-conversion 2U rack / tower UPS
Selectable 100/110/120/127V output (120V factory preset)
NEMA 5-15P input, 6 NEMA 5-15R outlets
Two switched 3-outlet load banks support remote reboot or programmable load shedding options
Supports 2% output voltage regulation and zero transfer time in double conversion mode
Economy mode option offers enhanced efficiency, reduced power consumption and lower BTU emissions
14 minutes runtime at 50% load (675W) and 4.2 minutes at 100% load (1350W) with internal batteries
BP48V24-2U (limit 1) or BP48V60RT3U (no limit) external battery packs available (some configurations require Tripp Lite's
External Battery
Configuration Software
)
LCD interface reports operating mode plus 9 selectable screens of UPS data (Load % & kW, Load % & kVA, Power factor, Input volts & Hz,
Output volts & Hz, Battery volts and charge %, Minutes runtime, Capacity remaining, Kw/hr. consumption)
LCD interface also supports 16 screens of UPS configuration and setup options