background image

UPS / Power
Module
dimensions in
primary form
factor (height x
width x depth / cm)

8.9 x 44.4 x 47

Rack Height

2U

Secondary form
factor

Tower (requires 

2-9USTAND

)

UPS / Power
Module weight (lbs)

45.2

UPS / Power
Module weight (kg)

20.5

UPS Shipping
dimensions
(height x width x
depth / inches)

9.5 x 20 x 24

UPS Shipping
dimensions
(height x width x
depth / cm)

24.1 x 50.8 x 61

Shipping weight
(lbs)

57.8

Shipping weight
(kg)

26.2

Cooling method

Fan

UPS housing
material

Steel

ENVIRONMENTAL

Operating
Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage
Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC mode BTU / hr.
(full load)

455

AC economy mode
BTU / hr. (full load)

292

Battery mode BTU
/ hr. (full load)

559

AC economy mode
efficiency rating
(100% load)

94%

Operating
Elevation (ft.)

0-3000m / 0-10,000 ft.

Audible Noise

45 dBA at 1m front side

COMMUNICATIONS

Communications
interface

USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface

Summary of Contents for SmartOnline SU1500RTXLCD2U

Page 1: ...bility HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Includes PowerAlert monitoring software and complete cabling Em...

Page 2: ...gs are reduced for some nominal voltage settings 127 120V 1350 watts 115V 1215 watts 110V 1148 watts 100V 1080 watts FREQUENCY REGULATION CONVERSION MODE Maximum output ratings are reduced in frequenc...

Page 3: ...ed Electrical Service 15A 120V BATTERY Full load runtime minutes 4 2 min 1350w Half load runtime minutes 14 min 675w Expandable battery runtime Extended runtime supported via optional external battery...

Page 4: ...ion and a variety of additional options Alarms Audible alarm indicates UPS startup power failure low battery overload UPS fault and remote shutdown conditions Alarm cancel operation Power fail alarm c...

Page 5: ...ethod Fan UPS housing material Steel ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius Storage Temperature Range 5 to 122 degrees Fahrenheit 15 to 50 degre...

Page 6: ...er bypass Hot swappable batteries Green high efficiency features High efficiency economy mode operation Individually controllable load banks Schedulable daily hours of economy mode operation CERTIFICA...

Page 7: ...outlets 2 NEMA 5 15P inputs 1 PDUMNV15 Single Phase Monitored PDU 15A 120V 0U Vertical Rackmount NEMA 5 15R outlets NEMA 5 15P input plug 1 PDUMV15NET Single Phase Switched PDU 15A 120V 0U Vertical Ra...

Reviews: