background image

 

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail: 

saleshelp@tripplite.com

Model #: SU1500XLCD

SmartOnline 1.5kVA On-Line Double-Conversion UPS, Tower, Interactive LCD display, 100/110/120/127V NEMA
5-15R outlets

 

Highlights

1500VA / 1.5kVA / 1350 watt on-line double-conversion tower UPS 

100/110/120/127V 50/60Hz output, 97% efficiency economy mode option

Interactive LCD with 10 selectable screens of UPS and site power data

USB, RS232 & EPO ports, SNMPWEBCARD option

Expandable runtime, Hot-swappable batteries

2 independently switchable load banks

NEMA 5-15P input; 6 5-15R outlets

Description

 Do you need to protect small- to medium-size servers, networking equipment and telecom systems against data loss, downtime and equipment
damage due to power outages, voltage fluctuations and transient surges? Tripp Lite’s SU1500XLCD SmartOnline® Tower UPS System is the
solution! Featuring a 1500VA/1350W capacity and true on-line operation with pure sine wave output and zero transfer time to battery, it provides the
highest level of power protection for mission-critical equipment. The SU1500XLCD’s large internal battery set supports connected equipment during
blackouts, and runtime is expandable with optional external battery packs (Tripp Lite model BP48V24-2U or BP48V60RT-3U), sold separately. The
SU1500XLCD has 6 5-15R outlets, including 2 load banks of 3 outlets each that are individually controllable to reboot select equipment on demand
or maximize battery runtime for mission-critical equipment. USB and DB9 communication ports support messaging of detailed UPS operational
parameters and line power status. Included PowerAlert power management software supports an unlimited number of network UPS systems. The
SU1500XLCD also accepts an optional SNMPWEBCARD accessory that enables the UPS to operate as a managed device on the network. It comes
backed by a 2-year warranty and $250,000 of Ultimate Lifetime Insurance. 

Package Includes

SU1500XLCD SmartOnline® Tower UPS System

PowerAlert Software CD and Cabling

Emergency Power Off (EPO) Cabling

Owner’s Manual

Features

Ideal for Protection of Mission-Critical Equipment

The SU1500XLCD provides true on-line operation, reliable battery backup and comprehensive power management capability in a compact tower

form factor. Featuring a 1500VA/1350W capacity, 6 5-15R outlets, a 10-ft. cord with standard 5-15P plug, USB/DB9 ports and a slot for an optional

SNMPWEBCARD, the SU1500XLCD offers a complete power protection solution for small- to medium-size servers, storage devices, telecom

systems and other mission-critical equipment. 

True On-Line Operation with Pure Sine Wave Output and Zero Transfer Time

The SU1500XLCD provides the highest level of protection available for mission-critical equipment. It actively converts raw incoming AC power to DC,

then re-converts it back to regulated, filtered AC output with a pure sine wave, completely isolating connected components from all power problems.

Zero transfer time between AC and battery operation maintains continuous output and further protects connected equipment from the disruptive

effects of blackouts and severe low-voltage conditions. Sine wave output guarantees compatibility with all equipment types.

Individually Controllable Outlets

The SU1500XLCD includes 2 load banks of 3 outlets each that are individually controllable via a software interface for remote reboot of locked-up

Summary of Contents for SmartOnline SU1500XLCD

Page 1: ...meters and line power status Included PowerAlert power management software supports an unlimited number of network UPS systems The SU1500XLCD also accepts an optional SNMPWEBCARD accessory that enables the UPS to operate as a managed device on the network It comes backed by a 2 year warranty and 250 000 of Ultimate Lifetime Insurance Package Includes SU1500XLCD SmartOnline Tower UPS System PowerAl...

Page 2: ... provides surge protection for a standard phone or network connection cable not included EMI RFI Line Noise Filtering Various electrical and radio sources can cause disruptive interference on the AC line This line noise is a common cause of incremental hardware damage data corruption and audio video performance problems The SU1500XLCD incorporates technology that filters out disruptive line noise ...

Page 3: ...ut frequency on startup Output matches input frequency when 5Hz of nominal Output is regulated to 0 05Hz when input frequency exceeds 5Hz of nominal UPS switches to battery mode when input frequency is below 40Hz or above 70Hz FREQUENCY REGULATION CONVERSION MODE Output is regulated to 0 05Hz of selected output frequency when input is 40 to 70Hz UPS switches to battery mode when input frequency is...

Page 4: ...teries Less than 3 hours from 10 to 90 Replacement battery cartridge internal UPS battery replacement RBC48 SUTWR Battery Access Battery access door Battery replacement description Hot swappable user replaceable batteries VOLTAGE REGULATION Voltage regulation description Online double conversion power conditioning Overvoltage correction 2 output voltage regulation during overvoltages to 150 Underv...

Page 5: ...ise suppression Yes PHYSICAL Installation form factors supported with included accessories Tower Primary form factor Tower UPS Power Module dimensions in primary form factor height x width x depth inches 10 2 x 9 x 19 5 UPS Power Module dimensions in primary form factor height x width x depth cm 25 9 x 22 9 x 49 5 UPS Power Module weight lbs 52 3 UPS Power Module weight kg 23 7 UPS Shipping dimens...

Page 6: ...ommunications cable USB and DB9 cabling included WatchDog compatibility Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer time Zero transfer time 0 ms in online double conversion and frequency regulation conversion modes Low voltage transfer to battery power setpoint 55V 33 load 70V 70 load 100V 100 load High voltage transfer to...

Page 7: ...uires ENVIROSENSE 1 PDUB15 Single Phase Hot Swap PDU 15A 120V 2U Horizontal Rackmount 8 NEMA 5 15R outlets set of 2 NEMA 5 15P input plugs 1 PDUMH15AT Single Phase Auto Transfer Switch Metered PDU 15A 120V 1U Horizontal Rackmount 8 NEMA 5 15R outlets 2 NEMA 5 15P inputs 1 PDUMNV15 Single Phase Monitored PDU 15A 120V 0U Vertical Rackmount 16 NEMA 5 15R outlets NEMA 5 15P input plug 1 PDUMV15NET Sin...

Reviews: