background image

UPS / Power
Module
dimensions in
primary form
factor (height x
width x depth / cm)

13.2 x 44.4 x 66

Rack Height

3U

UPS / Power
Module weight (lbs)

74

UPS / Power
Module weight (kg)

33.6

UPS Shipping
dimensions
(height x width x
depth / inches)

12 x 23 x 33

UPS Shipping
dimensions
(height x width x
depth / cm)

30.5 x 58.4 x 83.8

Shipping weight
(lbs)

120

Shipping weight
(kg)

54.4

Cooling method

Fan

UPS housing
material

Steel

ENVIRONMENTAL

Operating
Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage
Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC mode BTU / hr.
(full load)

1025

AC economy mode
BTU / hr. (full load)

585.9

Battery mode BTU
/ hr. (full load)

1258

AC economy mode
efficiency rating
(100% load)

94%

Operating
Elevation (ft.)

0-3000m / 0-10,000 ft.

Audible Noise

50 dBA at 1m front side

COMMUNICATIONS

Communications
interface

USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface

Network
monitoring port
description

Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure
communications

Summary of Contents for SmartOnline SU3000RTXLCD3U

Page 1: ...rs both enhanced RS 232 data and basic contact closure monitoring ability HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac O...

Page 2: ...127 120V 2700 watts 115V 2430 watts 110V 2295 watts 100V 2160 watts FREQUENCY REGULATION CONVERSION MODE Maximum output ratings are reduced in frequency regulation conversion mode 127 120V 1890 watts...

Page 3: ...Electrical Service 30A 120V BATTERY Full load runtime minutes 4 min 2700w Half load runtime minutes 11 min 1350w Expandable battery runtime Extended runtime supported via optional external battery pac...

Page 4: ...ting mode alarm function and a variety of additional options Alarms Audible alarm indicates UPS startup power failure low battery overload UPS fault and remote shutdown conditions Alarm cancel operati...

Page 5: ...it 0 to 40 degrees Celsius Storage Temperature Range 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 0 to 95 non condensing AC mode BTU hr full load 1025 AC economy mode BTU hr...

Page 6: ...mode operation CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Meets FCC Part 15 Category A EMI ROHS Restriction of Hazardous Substances WARRANTY Product Warranty Period Wo...

Page 7: ...lug 1 PDUMH30NET Single Phase Switched PDU 30A 120V 2U Horizontal Rackmount NEMA 5 15 20R outlets NEMA L5 30P input plug 1 PDUMNV30 Single Phase Monitored PDU 30A 120V 0U Vertical Rackmount NEMA 5 15...

Reviews: