Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail:
saleshelp@tripplite.com
Model #: SU5000RT3UHV
SmartOnline 5kVA On-Line Double-Conversion UPS, 5U Rack/Tower, 200-240V NEMA outlets
Highlights
5000VA / 5kVA / 3500 watt on-line double-conversion 5U rack/tower UPS
200/208/220/230/240V 50/60Hz output, high efficiency economy mode option
Hot-swappable battery modules
RS232 & EPO ports; support for SNMP/WEB card options
Front panel LEDs with detailed LCD monitoring and control screen
Expandable runtime with optional external battery packs
NEMA L6-30P input (3 wire); L6-30R & L6-20R outputs
Description
Tripp Lite 5kVA Smart Online RM UPS. 5000VA on-line, double-conversion UPS for server, network and telecommunications equipment. Maintains
battery derived AC output during blackouts with active, full-time power conditioning. Fault-tolerant auto-bypass prevents unexpected service
interruptions during overload or internal fault conditions. 3U power module and 2U battery pack install in 5 rack spaces. Full-time sine wave output
within 2% of selectable 200/208/220/230/240V AC. Corrects brownouts to 156V and overvoltages to 276V. Frequency regulation locks output power
to 50/60Hz (+/-0.2%)/Expandable runtime with optional rackmount external battery packs. Double-conversion UPS converts raw input from AC to
DC, then back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve
power problems not addressed by other UPS types. Highly efficient operation in optional economy mode setting, saving BTU heat output and energy
costs. Network-grade AC surge and noise suppression. Network management interfaces include 2 DB9 ports and SNMPWEBCARD slot. Supports
simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert
monitoring software and complete cabling. Emergency Power Off (EPO) interface. Front panel LEDs and LCD readout with scroll controls support
visual monitoring of all major UPS functions. Audible alarm. Self test. 4-post rackmount accessories included; 2-9USTAND and 2POSTRMKITWM
accessories available. L6-30P plug-in connection; built-in L6-30 & L6-20 outlets. Power Distribution Unit (PDU) options supported. Field-replaceable,
hot-swappable external battery packs. Attractive all-black color scheme. $250,000
connected equipment insurance
;
Features
True online, double-conversion UPS provides pure, full-time sine wave AC output free of surges, voltage fluctuations and line noise
5000VA/3500 watt output power capacity compatible with 200-240V applications at 50/60 Hz
3U power module and 2U battery pack installs in any 19 inch rack enclosure using only 5 rack spaces
Double conversion UPS actively converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from
harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
Provides perfectly regulated, sine wave output power free of line noise, transient surges and frequency variation for the most efficient
operation of critical servers, networking and telecommunications equipment
Accepts input voltages between 156 and 276, regulating output within 2% of selected 200/208/220/230/240V nominal voltage
Supports connected equipment during blackouts for 20/8 minutes at half/full load levels. Runtime is further expandable with optional
external battery packs
Network interfaces support simultaneous communications via 2 DB9 ports and SNMPWEBCARD slot
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus
any number of additional servers over IP
Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge