Tripp Lite SU5000RT4UTF 5000VA / 5kVA / 4500 watt on-line, double-conversion UPS system in a 6U rack/tower configuration (4U UPS

power module with internal bat 2U step-down transformer)

Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions

and line noise

Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions

L6-30P input plug, plus 2 L6-30R, 2 L6-20R and 12 5-15/20R outlets

Included rail kits support rackmount installation of both included modules in 4 post racks

Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (2 required for SU5000RT4UTF)

Optional 2-9USTAND supports upright tower placement (1 required for SU5000RT4UTF)

Maximum installed rack depth of only 20.75 in. / 52.7 cm

Maintains full-time sine wave output within 2% of 208V & 120V at 60Hz nominal in double conversion mode

Corrects brownouts to 156V at full load (100V at 50% load or less)

Corrects overvoltages to 290V at full load (300V at 90% load or less)

Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with

enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS

types

High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs

Network-grade AC surge and noise suppression

Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional

SNMP card slot interfaces

UPS card slot supports one card-based network interface option (part # SNMPWEBCARD) or dry-contact monitoring accessory (part #

RELAYIOCARD)

Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces

Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification

Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires

removal of USB interface module)

HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X

Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA

(Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250

SNMP-enabled UPS, PDU and other networking devices

Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a

variety of control options to support advanced UPS settings and configurations

LED/LCD display panel rotates for viewing in rackmount or tower configurations

Supports Emergency Power Off (EPO) via built-in interface

Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries

are expired and require replacement

External battery packs are field replaceable and hot swappable

Some external battery configurations require the use of Tripp Lite's 

External Battery Configuration Software

 (see manual)

$250,000 connected equipment insurance;

Specifications

OUTPUT

Output Volt Amp
Capacity (VA)

5000

Output kVA capacity
(kVA)

5.0

Output Watt Capacity
(watts)

4500

Output kW capacity

4.5

Output power factor

0.9

Crest Factor

3:1

Nominal Output
Voltage(s) Supported

120V; 208V

Summary of Contents for SmartOnline SU5000RT4UTF

Page 1: ...eries are expired and require replacement Double conversion operation converts raw input from AC to DC then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmon...

Page 2: ...one card based network interface option part SNMPWEBCARD or dry contact monitoring accessory part RELAYIOCARD Optional SNMPWEBCARD offers communications and control via secure remote web and network...

Page 3: ...otect 3 5 15 20R outlets each Output AC waveform AC mode Pure sine wave Output AC waveform battery mode Pure Sine wave INPUT Rated input current at maximum load 24A 208V Nominal Input Voltage s Suppor...

Page 4: ...see manual Alarms Unique audible alarms for all major UPS environmental and power conditions see manual Alarm cancel operation Alarm cancel switch Switches 2 Switches control off on power status and...

Page 5: ...Stepdown transformer weight kg 34 5 UPS Shipping dimensions height x width x depth inches 22 x 25 x 30 UPS Shipping dimensions height x width x depth cm 55 9 x 63 5 x 76 2 Shipping weight lbs 278 Shi...

Page 6: ...100V 50 load or less derates linearly High voltage transfer to battery power setpoint 280V full load 300V 90 load or less SPECIAL FEATURES Cold Start startup in battery mode during a power failure Co...

Page 7: ...arranty For SU5000RT3UHV UPS only 1 WEXT5 SU5000HV 5 Year Extended Warranty For SU5000RT3UHV UPS only 1 2POSTRMKITHD Enables 2 Post Rackmount Installation of 3U and Larger UPS Transformer and Battery...

Reviews: