background image

Installed whole
system maximum
rack depth (inches)

20.75

Installed whole
system maximum
rack depth (cm)

52.7

Rack Height

6U

Secondary form factor

Tower

UPS / Power Module
weight (lbs)

113.6

UPS / Power Module
weight (kg)

51.6

Stepdown transformer
dimensions (height x
width x depth / inches)

3.5 x 17.5 x 20.75

Stepdown transformer
dimensions (height x
width x depth / cm)

8.8 x 44.4 x 52.7

Stepdown transformer
weight (lbs)

76

Stepdown transformer
weight (kg)

34.5

UPS Shipping
dimensions (height x
width x depth / inches)

22 x 25 x 30

UPS Shipping
dimensions (height x
width x depth / cm)

55.9 x 63.5 x 76.2

Shipping weight (lbs)

278

Shipping weight (kg)

126.2

Cooling method

Fan

UPS housing material

Sheet metal

ENVIRONMENTAL

Operating
Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature
Range

5 to 122 F / -15 to 50 C

Relative Humidity

5% to 90% (non-condensing)

AC mode BTU / hr.
(full load)

1767

AC economy mode
BTU / hr. (full load)

638

Battery mode BTU /
hr. (full load)

1700

AC economy mode
efficiency rating (100%
load)

96%

Summary of Contents for SmartOnline SU5000RT4UTF

Page 1: ...eries are expired and require replacement Double conversion operation converts raw input from AC to DC then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmon...

Page 2: ...one card based network interface option part SNMPWEBCARD or dry contact monitoring accessory part RELAYIOCARD Optional SNMPWEBCARD offers communications and control via secure remote web and network...

Page 3: ...otect 3 5 15 20R outlets each Output AC waveform AC mode Pure sine wave Output AC waveform battery mode Pure Sine wave INPUT Rated input current at maximum load 24A 208V Nominal Input Voltage s Suppor...

Page 4: ...see manual Alarms Unique audible alarms for all major UPS environmental and power conditions see manual Alarm cancel operation Alarm cancel switch Switches 2 Switches control off on power status and...

Page 5: ...Stepdown transformer weight kg 34 5 UPS Shipping dimensions height x width x depth inches 22 x 25 x 30 UPS Shipping dimensions height x width x depth cm 55 9 x 63 5 x 76 2 Shipping weight lbs 278 Shi...

Page 6: ...100V 50 load or less derates linearly High voltage transfer to battery power setpoint 280V full load 300V 90 load or less SPECIAL FEATURES Cold Start startup in battery mode during a power failure Co...

Page 7: ...arranty For SU5000RT3UHV UPS only 1 WEXT5 SU5000HV 5 Year Extended Warranty For SU5000RT3UHV UPS only 1 2POSTRMKITHD Enables 2 Post Rackmount Installation of 3U and Larger UPS Transformer and Battery...

Reviews: