Accepts input voltages between 80-138V (65-138V at loads under 70%), regulating output to 120V AC +/-2%
750VA/600W output capacity with 6 x NEMA5-15R outlets
Two built-in individually switchable load banks can be controlled via software interface to selectively reboot remote equipment or shed less
critical loads to extend battery runtime for the most critical equipment (1 outlet per bank)
Standard internal battery set provides 11 min. runtime at half load and 4 min. at full load
Extended runtime available with optional BP24V15RT2U, BP24V28-2U, or BP24V70-3U external battery packs
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
DB9 serial network interface supports RS-232 and contact closure messaging
Slot for optional SNMP/WEB card (part# SNMPWEBCARD)
Included PowerAlert UPS power management software and cabling provides monitoring of in-depth site power conditions, full UPS status
and fault warnings, output load level and load bank power control
Compatible with Tripp Lite's WatchDog service monitoring/rebooting software (part# WATCHDOGSW)
Fault-tolerant auto-bypass maintains continuous utility output to connected equipment, even in cases where the UPS is overloaded or
suffers an internal failure that requires service
Diagnostic LEDs
Upright tower format; attractive all-black color scheme
$250,000 Ultimate Lifetime
connected equipment insurance
(USA & Canada only)
2-year warranty
Specifications
SYSTEM OVERVIEW
Voltage compatibility
120V (110V, 100V) AC
Frequency
compatibility
50/60 Hz compatible
OUTPUT
Output VA
750
Output watts
600
Output nominal
voltage
120 VAC
Output voltage
regulation
Maintains full-time sine wave output within 2% of 120V, less than 5% total harmonic distortion
Output frequency
regulation
Regulates line frequency to 50/60Hz +/- 0.05Hz
Outlet quantity / type
6 x NEMA 5-15R
Customized load
management
receptacles
2 individually controllable singe-outlet load banks support load shedding and remote reboot on demand of locked
network devices. Configurable with PowerAlert Software to switch off optional loads, like monitors, to increase available
runtime for servers and other critical devices.
Overload protection
15A input breaker
INPUT
Maximum input
amps
6.2A
Input connection
type
NEMA 5-15P
Input cord length
10 ft.
Recommended
Electrical Service
15A 120V
BATTERY
Full load runtime
4 min.
Half load runtime
11 min.
DC system voltage
24VDC
Typical battery
lifespan
4-6 years typical