background image

LEDS ALARMS & SWITCHES

LED Indicators

6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD
screen offers additional information and control options

Front panel LCD display

Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options;
LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN,
ITALIAN, SPANISH and PORTUGUESE (see manual)

Alarms

Unique audible alarms for all major UPS, environmental and power conditions (see manual)

Alarm cancel operation

Alarm cancel switch

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and
execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module
replacement

SURGE / NOISE SUPPRESSION

UPS AC suppression response time

Instantaneous

EMI / RFI AC noise suppression

Yes

PHYSICAL

Installation form factors supported
with included accessories

Tower

Included mounting accessory
description

2 sets of adjustable 4 post rack rails included; 2-9USTAND tower kit included (supports up to 9U in tower format)

Installation form factors supported
with optional accessories

2 post rackmount (2POSTRMKITHD)

Optional mounting accessory notes

2 sets of 

2POSTRMKITHD

 required for 2 post rackmount installation of separate power module and battery pack

Primary form factor

Rackmount

UPS / Power Module dimensions in
primary form factor (height x width x
depth / inches)

5.14 x 17.5 x 25.82

UPS / Power Module dimensions in
primary form factor (height x width x
depth / cm)

13.1 x 44.4 x 65.6

Installed whole system maximum
rack depth (inches)

32.5

Installed whole system maximum
rack depth (cm)

82.6

Rack Height

6U

Secondary form factor

Tower

UPS / Power Module weight (lbs)

43

UPS / Power Module weight (kg)

19.5

Included battery pack dimensions
(height x width x depth / inches)

5.25 x 17.5 x 25

Included battery pack dimensions
(height x width x depth / cm)

13.3 x 44.4 x 63.5

4 / 7 

 

Summary of Contents for SmartOnline SU8000RT3UG

Page 1: ...lets Maximum installed rack depth of only 32 5 in 82 6cm inches Full time active power conditioning provides clean continuous dual conversion AC output free of voltage fluctuations power interruptions...

Page 2: ...igurable hard contact closure outputs for custom event notification requires removal of USB interface module Supports Emergency Power Off EPO via built in interface Included rail kit supports 6U 19 in...

Page 3: ...age s Supported 200V AC 208V AC 230V AC 240V AC UPS input connection type Hardwire UPS input connection description 3 wire single phase input L1 L2 G Recommended Electrical Service 50A Voltage compati...

Page 4: ...tantaneous EMI RFI AC noise suppression Yes PHYSICAL Installation form factors supported with included accessories Tower Included mounting accessory description 2 sets of adjustable 4 post rack rails...

Page 5: ...perating Elevation ft 0 3000m 0 to 10 000 ft Audible Noise 60 dBA at front side 1 meter Operating Elevation m 0 3000 m COMMUNICATIONS Communications interface USB HID enabled DB9 Serial EPO emergency...

Page 6: ...nty Period Worldwide 2 year limited warranty Related Items Optional Products Model Number Description Qty SNMPWEBCARD For remote monitoring and control via SNMP Web or Telnet 1 ENVIROSENSE Monitors te...

Page 7: ...Outlets Current Metering Remote Monitoring and Control 1 P032 007 7 ft 12AWG Heavy Duty Power cord IEC 320 C13 to IEC 320 C20 1 P036 002 2 ft 12AWG Heavy Duty Power cord IEC 320 C19 to IEC 320 C20 1...