Model #: SU8000RT3UN50

SmartOnline 8kVA On-Line Double-Conversion UPS, 6U Rack/Tower, 200-240V NEMA outlets, 50A plug

 

Highlights

8kVA / 8000VA / 7200W on-line double-conversion UPS; 0.9 power factor

200/208/220/230/240V 50/60Hz output, Economy mode option

6U Rack/Tower configuration; Hot-swap power and battery modules

USB, RS232 & EPO ports; SNMP/WEB and contact-closure card options

Front panel LEDs with detailed LCD monitoring and control screen

Expandable runtime with optional external battery packs

Hubbell CS8265 input (3 wire); L6-30R & L6-20R outlets

Description

 Tripp Lite SU8000RT3UN50 8000VA / 8kVA / 7200 watt online, double-conversion UPS system offers complete power protection for critical network
applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications.
Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with
manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced
availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers,
computer rooms, network closets and rugged industrial applications. 

Package Includes

SU8000RT3UPM 3U UPS power module

BP240V10RT3U external battery pack

SUPDMB710 Detachable PDU with manual bypass switch

Four post compatible rack rail kit (2 sets)

Tower stands for upright tower configuration

PowerAlert software, complete data cabling and user manual

Features

Tripp Lite SU8000RT3UN50 8kVA / 8000VA / 7200 watt on-line, double-conversion UPS system in 6U total rack/tower configuration (3U

UPS power module and 3U external battery pack)

Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no interruption in output power to

connected networking equipment

Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions

Hubbell CS8265 (208/240V 50A) or Hardwire input; 2 L6-30R and 4 L6-20R outlets

Maximum installed rack depth of only 32.5 in. / 82.6cm inches

Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions

and line noise

Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with

enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS

types

Maintains full-time sine wave output within 2% of selectable 208/240V nominal during brownouts as low as 100V and overvoltages as high

as 300V

Supports 50/60Hz operation for worldwide frequency compatibility

Expandable runtime is supported with optional BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH;

BP240V1407C-1PH external battery packs

Summary of Contents for SmartOnline SU8000RT3UN50

Page 1: ...Package Includes SU8000RT3UPM 3U UPS power module BP240V10RT3U external battery pack SUPDMB710 Detachable PDU with manual bypass switch Four post compatible rack rail kit 2 sets Tower stands for upri...

Page 2: ...luded rail kit supports 6U 19 inch rackmount installation in 4 post racks Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks Optional 2 9USTAND supports upright tower placement Front...

Page 3: ...ection description 3 wire single phase input L1 L2 G UPS Input cord length ft 10 UPS Input cord length m 3 Recommended Electrical Service 208 240V 50A BATTERY Full load runtime minutes 5 5 min 7200w H...

Page 4: ...s support set and execute scrolling LCD functions bundled PDU includes bypass switch to enable hot swap UPS power module replacement SURGE NOISE SUPPRESSION UPS AC suppression response time Instantane...

Page 5: ...width x depth inches 39 8 x 31 5 x 23 UPS Shipping dimensions height x width x depth cm 101 x 80 x 58 4 Shipping weight lbs 331 Shipping weight kg 150 3 UPS housing material Steel Cooling method Fan...

Page 6: ...FEATURES Cold Start startup in battery mode during a power failure Cold start operation supported Economy mode operation Optional economy mode enables high efficiency bypass operation with a maximum...

Page 7: ...Metered 0U Vertical Rack PDU Metered Power Distribution Unit for Network Applications 1 Power Distribution PDUMV20HVNET Switched Metered PDU with Remote Monitoring 0U Vertical Rackmount Power Distribu...