Basic Operation 

continued

Indicator Lights (Front Panel)

All Indicator Light descriptions apply when the UPS is plugged into a wall outlet
and turned ON.

“POWER” LED: 

this green LED lights continuously when the UPS is ON and

supplying connected equipment with AC power from a utility source. The LED
flashes and an alarm sounds (4 short beeps followed by a pause) to indicate the
UPS is operating from its internal batteries during a blackout or severe
brownout. If the blackout or severe brownout is prolonged, you should save
files and shut down your equipment since internal battery power will eventual-
ly be depleted. See “BATTERY CHARGE” LED description below. 

“VOLTAGE CORRECTION” LED:

this green LED lights continuously

whenever the UPS is automatically correcting high or low AC voltage on the
utility line without the assistance of battery power. The UPS will also emit a
slight clicking noise. These are normal, automatic operations of the UPS, no
action is required on your part.

“OUTPUT LOAD LEVEL” LED: 

this multicolored LED indicates the

approximate electrical load of equipment connected to the UPS's AC outlets. It
will turn from green (light load) to yellow (medium load) to red (overload). If
the LED is red (either illuminated continuously or flashing), clear the overload
immediately by unplugging some of your equipment from the outlets until the
LED changes from red to yellow (or green). CAUTION! Any overload that is
not corrected by the user immediately may cause the UPS to shut down and
cease supplying output power in the event of a blackout or brownout.

“BATTERY CHARGE” LED: 

when the UPS is operating from utility power,

this LED indicates the approximate charge state of the UPS's internal batteries:
red indicates the batteries are beginning to charge; yellow indicates the batteries
are roughly midway through charging; and green indicates the batteries are fully
charged. When the UPS is operating from battery power during a blackout or
severe brownout, this LED indicates the approximate amount of energy (ulti-
mately affecting runtime) which the UPS’s batteries will provide: red indicates
a low level of energy; yellow indicates a medium level of energy; and green
indicates a high level of energy. Since the runtime performance of all UPS bat-
teries will gradually deplete over time, it is recommended that you periodically
perform a self-test (see MUTE/TEST Button description) to determine the energy
level of your UPS batteries BEFORE a blackout or severe brownout occurs.
During a prolonged blackout or severe brownout, you should save files and shut
down your equipment since battery power will eventually be depleted. When the
LED turns red and an alarm sounds continuously, it indicates the UPS's batteries
are nearly out of power and UPS shut down is imminent.

“BATTERY WARNING” LED:

this LED lights red and an alarm sounds

intermittently after you complete a self test (See “MUTE/TEST” Button descrip-
tion) to indicate the UPS batteries need to be recharged or replaced. Allow the
UPS to recharge continuously for 12 hours, and repeat the self-test. If the LED
continues to light, contact Tripp Lite for service. If your UPS requires battery
replacement, visit www.tripplite.com/support/battery/index.cfm to locate the spe-
cific Tripp Lite replacement battery for your UPS.

8

200309053 93-2186 SmartProInt Owner’s Manual.qxd  3/30/2004  11:42 AM  Page 8

Summary of Contents for SmartPro AGSM152DRTi2U

Page 1: ...añol Copyright 2004 Tripp Lite All rights reserved SmartPro is a registered trademark of Tripp Lite SmartPro Rackmount Intelligent Line Interactive UPS Systems SMX500RT1U SMX750RT1U SMX1500XLRT2U SMX3000XLRT2U 230V Sine Wave Input Output 500VA 3000VA Capacities Extended Run Options SMX1500XLRT2U and SMX3000XLRT2U models 13 Battery Replacement 12 Specifications 12 Français 25 Optional Installation ...

Page 2: ...lications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors or extension cords to the output of your UPS This might overload the UPS and will void the surge suppressor and UPS warranties Battery Warnings Except for battery replacement your UPS does not require routine mai...

Page 3: ...t include an adjustable rackmount shelf kit skip steps 1 and 2 Connect the two segments of each shelf using the included screws and nuts Leave the screws slightly loose so that the shelves can be adjusted in the next step Adjust each shelf to fit your rack then mount them in the lowest available space of your rack with the screws nuts and washers provided Note that the support ledges should face i...

Page 4: ...ft your UPS and attach it to the rack by passing the screws nuts and washers provided through its mounting ears and into the rack rails D C B A 1 2 B A D C 1 2 Mounting Tower 4 Mount all UPS models in an upright tower position using included hardware The user must deter mine the fitness of hardware and procedures before mounting All UPS Models Stand your UPS on its side with the LED Control panel ...

Page 5: ...ment into the UPS Plug your equipment into the UPS Repeat step 3 above using the additional power cord s that came with the UPS Note Additional interconnection cords C13 to C14 are available from Tripp Lite Call 773 869 1234 Part P004 006 Your UPS is designed to support only computer equipment You will overload the UPS if the total VA ratings for all the equipment you connect exceeds the UPS s Out...

Page 6: ...nnected to this circuit it enables emergency shutdown of the UPS s inverter Using the cable provided connect the EPO port of your UPS see to a user supplied normally closed or normally open switch according to the circuit diagram see The EPO port is not a phone line surge sup pressor do not connect a phone line to this port External Battery Connection select models All UPS models come with a robus...

Page 7: ...by Charge Only mode see POWER Button description CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical grounding and may introduce a damaging surge into your network connections Results of a Self Test the test will last approximately 10 seconds as the UPS switches to battery to test its load capacity and battery charge All LEDs will be lit and the UPS alarm will sou...

Page 8: ...lackout or brownout BATTERY CHARGE LED when the UPS is operating from utility power this LED indicates the approximate charge state of the UPS s internal batteries red indicates the batteries are beginning to charge yellow indicates the batteries are roughly midway through charging and green indicates the batteries are fully charged When the UPS is operating from battery power during a blackout or...

Page 9: ...r outlets Select models also feature outlets labelled UNSWITCHED which may not be remotely switched off Unswitched outlets can only be turned off by turning off all of the output receptacles See software instructions for details Communications Ports USB or RS 232 These ports connect your UPS to any workstation or server Use with Tripp Lite s PowerAlert Software and included cables to enable your c...

Page 10: ...by experimenting with different settings for this dial As the dial is turned clockwise the UPS becomes more tolerant of variations in its input power s AC waveform NOTE The further the dial is adjusted clockwise the greater the degree of waveform distortion the UPS will allow to pass to connected equipment When experimenting with different settings for this dial operate connected equipment in a sa...

Page 11: ...s is the most common cause of service inquiries which can be easily remedied by following the resetting instructions in this manual 2 If the problem continues do not contact or return the UPS to the dealer Instead call Tripp Lite at 773 869 1233 A service technician will ask for the UPS s model number serial number and purchase date and will attempt to correct the problem over the phone 3 If the p...

Page 12: ...ternal battery packs Adding external battery packs will also increase recharge time ALL MODELS Voltage Regulated Output Voltage Range 230V 9 On Battery Output Voltage Range 230V 5 AC Surge Suppression exceeds IEEE 587 Cat A B standards AC Noise Attenuation 40 dB AC Protection Modes H to N The policy of Tripp Lite is one of continuous improvement Specifications are subject to change without notice ...

Page 13: ...1111 W 35th Street Chicago IL 60609 USA 773 869 1234 USA 773 869 1212 International www tripplite com ...

Reviews: