background image

Mains power and voltage regulation LEDs offer at-a-glance power status information

Front panel switches support self-test and alarm cancel functions

Field replaceable, hot-swappable internal UPS batteries 

Specifications

OUTPUT

Output Volt Amp Capacity
(VA)

1000

Output kVA capacity (kVA)

1

Output Watt Capacity
(watts)

800

Output power factor

0.8

Nominal Output Voltage(s)
Supported

120V

Frequency compatibility

60 Hz

Output voltage regulation
(line mode)

-21%, +8%

Output voltage regulation
(Battery mode)

+/- 5%

Built-in UPS output
receptacles

6 5-15R outlet(s)

Built-in controllable
switched load banks

Two switchable single-outlet 5-15R load banks

Output AC waveform (AC
mode)

Sine wave

Output AC waveform
(battery mode)

Pure Sine wave

INPUT

Rated input current (at
maximum load)

9.2A

Nominal Input Voltage(s)
Supported

120V AC

UPS input connection type

5-15P

Input circuit breaker

15A

Recommended Electrical
Service

15A 120V

Input cord length (ft.)

10

Input cord length (m)

3

BATTERY

Full load runtime (minutes)

4 min. (800w)

Half load runtime (minutes)

14 min. (400w)

DC system voltage (VDC)

24

Battery recharge rate
(included batteries)

Less than 4 hours from 10% to 90%

Summary of Contents for SmartPro SMART1000RM1U

Page 1: ...nual Features Tripp Lite SMART1000RM1U 1kVA 1000VA 800 watt line interactive UPS 1U rack tower compatible form factor NEMA 5 15P input 6 5 15R output receptacles Installed depth of only 16 75 in 42 5cm Sine wave output in both AC and battery backup modes Line Interactive UPS provides Automatic Voltage Regulation AVR to maintain 120V nominal output during brownouts to 83V and overvoltages to 147V w...

Page 2: ...age regulation Battery mode 5 Built in UPS output receptacles 6 5 15R outlet s Built in controllable switched load banks Two switchable single outlet 5 15R load banks Output AC waveform AC mode Sine wave Output AC waveform battery mode Pure Sine wave INPUT Rated input current at maximum load 9 2A Nominal Input Voltage s Supported 120V AC UPS input connection type 5 15P Input circuit breaker 15A Re...

Page 3: ...conditions Alarm cancel operation Power fail alarm can be silenced using alarm cancel switch once silenced alarm will re sound to indicate low battery status Switches 2 Switches control off on power status and alarm cancel self test operation SURGE NOISE SUPPRESSION UPS AC suppression joule rating 450 joules EMI RFI AC noise suppression Yes AC suppression response time Instantaneous PHYSICAL Prima...

Page 4: ...d hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer time 5 milliseconds AC to DC 1 millisecond DC to AC Low voltage transfer to battery power setpoint 83 High voltage transfer to battery power setpoint 147 SPECIAL FEATURES Grounding lug Back panel grounding lug Cold Start startup in battery mode during a power failure Cold start operation supported High availabilit...

Page 5: ...r Telnet 1 Surge Protectors DCATV Network Surge Suppressor Essential protection for TV VCR coaxial lines 1 Surge Protectors DNET1 Network Surge Suppressor Essential protection for data and communication lines 1 Surge Protectors DTEL2 Network Surge Suppressor Essential protection for data and communication lines 1 USB Hubs Accessories U022 010 10 ft USB2 0 A B Gold Device Cable A Male to B Male 1 M...

Reviews: