background image

SNMPWEBCARD), or the monitoring of any number of additional UPS systems over IP with included PowerAlert monitoring software. 

Communications ports support messaging of UPS and line power status, including on battery, low-battery, power restored, AC line voltage,

DC battery voltage and remaining battery capacity

Supports timed inverter shutoff after unattended shutdown, activate self-test and UPS output power control for a delayed or immediate

reboot of connected devices

Supports Tripp Lite's WatchDog software application to restore unresponsive programs by systematically restarting applications, operating

systems and ultimately rebooting completely locked computers by momentarily switching UPS power off and back on again (requires

optional WATCHDOGSW)

Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter

Emergency Power Off (EPO) interface with cable 

Multi-function audible alarms and set of 5 front panel LEDs

Network-grade AC surge suppression 

Attractive all-black color scheme

UPS battery set ships fully assembled and ready for installation, no time consuming connection of internal batteries by user is necessary

Specifications

OUTPUT

Output Volt Amp Capacity
(VA)

1500

Output kVA capacity (kVA)

1.5

Output Watt Capacity
(watts)

1000

Output kW capacity

1

Output power factor

0.7

Nominal Output Voltage(s)
Supported

120V

Frequency compatibility

60 Hz

Output voltage regulation
(line mode)

-21%, +8%

Output voltage regulation
(Battery mode)

+/- 5%

Built-in UPS output
receptacles

8 5-15R outlet(s)

Built-in controllable
switched load banks

Two switchable two-outlet 5-15R load banks

Output AC waveform (AC
mode)

Sine wave

Output AC waveform
(battery mode)

Pure Sine wave

INPUT

Rated input current (at
maximum load)

10.4A

Nominal Input Voltage(s)
Supported

120V AC

UPS input connection type

5-15P

Input circuit breaker

15A

UPS Input cord length (ft.)

10

Summary of Contents for SmartPro SMART1500RM2U

Page 1: ...n unlimited number of network UPS systems Built in accessory slot supports SNMP with optional SNMPWEBCARD adapter Emergency Power Off EPO interface offers option for instantaneous power off of UPS and connected equipment in the case of fire or emergency Multi function audible alarms and set of 5 front panel LEDs offer at a glance notification of UPS and line power status Network grade AC surge sup...

Page 2: ...ter Emergency Power Off EPO interface with cable Multi function audible alarms and set of 5 front panel LEDs Network grade AC surge suppression Attractive all black color scheme UPS battery set ships fully assembled and ready for installation no time consuming connection of internal batteries by user is necessary Specifications OUTPUT Output Volt Amp Capacity VA 1500 Output kVA capacity kVA 1 5 Ou...

Page 3: ...S SWITCHES LED Indicators 5 LEDs indicate line power battery power overload voltage regulation and battery low replace status Alarms Audible alarm indicates power failure overload and low battery conditions Alarm cancel operation Power fail alarm can be silenced using alarm cancel switch once silenced alarm will re sound to indicate low battery status Switches 2 Switches control off on power statu...

Page 4: ... 40 degrees Celsius Storage Temperature Range 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 0 to 95 non condensing AC mode BTU hr full load 105 2 Battery mode BTU hr full load 600 COMMUNICATIONS Communications interface USB DB9 Serial EPO emergency power off Slot for SNMP Web interface Network monitoring port description Supports detailed monitoring of UPS and site power c...

Page 5: ...uty 14AWG Power cord IEC 320 C13 to NEMA 5 15P 1 Power Cables P007 010 10 ft Heavy Duty 14AWG Power cord IEC 320 C13 to NEMA 5 15P 1 Power Cables P010 012 12 ft 18AWG Power cord NEMA 5 15P to IEC 320 C13 1 Power Cables P022 001 1 ft 18AWG Power Extension cord NEMA 5 15R to NEMA 5 15P 1 Power Cables P023 001 1 ft 14AWG Power Adapter cord NEMA L5 15R to NEMA 5 15P 1 Power Cables P034 010 10 ft 14AWG...

Page 6: ... for critical networking equipment 1 Rackmount Wallmount Kits 2POSTRMKITWM Enables 2 Post Rackmount or Wallmount Installation of Select Rackmount UPS Systems 1 Replacement Batteries RBC93 2U 2U UPS Replacement Battery Cartridge for select Tripp Lite SmartPro UPS 1 SNMP Accessories ENVIROSENSE Monitors temperature humidity and contact closure inputs Requires SNMPWEBCARD or switched PDU 1 SNMP Acces...

Reviews: