background image

 

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail: 

saleshelp@tripplite.com

Model #: SMART700

SmartPro Tower UPS System - Intelligent, line-interactive battery backup and network power management

 

Highlights

700VA line interactive tower UPS

Maintains 120V nominal output over an input range of 75 to 147V

Network communications supported via USB port

Current monitoring

Input: NEMA 5-15P (120V 15A) / Output: 6 NEMA 5-15R (120V)

2 year product warranty / $250,000 Ultimate Lifetime Insurance (USA, Puerto

Rico & Canada only) 

Description

Tripp Lite's SMART 700 intelligent, line interactive UPS system protects servers, networking accessories and telecommunications equipment from

blackouts, voltage fluctuations and transient surges. Large internal batteries offer 20 minutes half load runtime and 6 minutes at full load during

power failures. 700VA/450 watt power handling capability supports a variety of networking, telecom and various other application types, including the

support of multiple network workstations. Includes a total of 6 UPS supported outlets. Supports remote monitoring of UPS and site power conditions

via built-in USB monitoring port. Includes PowerAlert UPS monitoring and unattended shutdown software with complete cabling. Built-in audible

alarm and 5 front panel LEDs indicate status of line power, battery power, battery low/replace, voltage regulation and load level. Wall mountable

with UPSWM wallmount bracket. Network-grade AC surge suppression protects equipment from damage and performance problems resulting from

transient surges. Attractive, small-footprint tower housing uses less than 53 square inches of floor or desktop space. Two year warranty with

$250,000 

connected equipment insurance

.

Package Includes

SMART 700 UPS System

Monitoring cable

PowerAlert unattended shutdown and UPS/Power monitoring software

Instruction manual with warranty information

Features

700VA/450 watt power handling capability supports a variety of networking, telecom and various other application types

Built-in voltage regulation and battery support, plus complete AC line surge suppression prevents equipment damage, data loss and

downtime

Large internal batteries offer 20 minutes half load runtime and 6 minutes at full load during power failures

Automatic Voltage Regulation (AVR) circuits with two boost and one voltage reduction level maintains usable 120V nominal output over an

input voltage range of 75-147V

Includes a total of 6 NEMA5-15R outlets

Includes USB communications port for remote monitoring of UPS status and site power conditions

Communications port enables safe unattended shutdown without data loss during extended power failures

Communications port supports messaging of UPS and line power status, including on-battery, low-battery, power-restored, AC line voltage,

DC battery voltage and battery capacity

Communications ports support timed inverter shutoff after unattended shutdown, activate self-test and 10 second reboot of connected

Summary of Contents for SmartPro SMART700

Page 1: ...d load level Wall mountable with UPSWM wallmount bracket Network grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges Attractive small footprint tower housing uses less than 53 square inches of floor or desktop space Two year warranty with 250 000connected equipment insurance Package Includes SMART 700 UPS System Monitoring cable PowerA...

Page 2: ...cifications OUTPUT Output Volt Amp Capacity VA 700 Output Watt Capacity watts 450 Output power factor 0 6 Nominal Output Voltage s Supported 115V 120V Frequency compatibility 60 Hz Output voltage regulation line mode 18 8 Output voltage regulation Battery mode 115V 5 Built in UPS output receptacles 6 5 15R outlet s Basic PDU options PDU1215 1U 13 5 15R outlets PDUNV 1U 2 C19 12 C13 outlets PDU1415...

Page 3: ...tages between 128 and 147 are reduced by 12 Undervoltage correction Input voltages between 93 and 107 are boosted by 14 Severe undervoltage correction Input voltages between 75 and 92 are boosted by 30 LEDS ALARMS SWITCHES LED Indicators 5 LEDs indicate line power battery power overload voltage regulation and battery low replace status Alarms Audible alarm indicates power failure and low battery c...

Page 4: ... depth cm 39 4 x 27 9 x 28 6 Shipping weight lbs 24 Shipping weight kg 10 9 UPS housing material PVC ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius Storage Temperature Range 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 0 to 95 non condensing AC mode BTU hr full load 133 Battery mode BTU hr full load 565 9 COMMUNICATIONS Comm...

Page 5: ...eractive and Online Tower or Rack models 1500VA or less 1 Power Distribution PDU1215 Basic PDU Power Distribution Unit Safe reliable power distribution for critical networking equipment 1 Surge Protectors DCATV Network Surge Suppressor Essential protection for TV VCR coaxial lines 1 Surge Protectors DNET1 Network Surge Suppressor Essential protection for data and communication lines 1 Surge Protec...