background image

Green & high efficiency
features

Individually controllable load banks

CERTIFICATIONS

UPS Certifications

CE; Meets FCC Part 15 Category A (EMI)

UPS Certification details

CE 62040

WARRANTY

Product Warranty Period
(International)

2-year limited warranty

Product Warranty Period
(Mexico)

2-year limited warranty

Product Warranty Period
(Puerto Rico)

2-year limited warranty

Related Items

Optional Products

Related Model

Description

Qty.

DCATV

Network Surge Suppressor - Essential protection for TV/VCR coaxial lines 

1

DNET1

Network Surge Suppressor - Essential protection for data and communication lines 

1

DTEL2

Network Surge Suppressor - Essential protection for data and communication lines 

1

ENVIROSENSE

Monitors temperature, humidity and contact-closure inputs. (Requires SNMPWEBCARD
or switched PDU.) 

1

PDU12IEC

Basic PDU / Power Distribution Unit - Safe, reliable power distribution for critical
networking equipment 

1

P004-006

6-ft. 18AWG Power cord
(IEC-320-C14 to IEC-320-C13) 

1

SNMPWEBCARD

For remote monitoring and control via SNMP, Web, or Telnet. 

1

U022-010

10-ft. USB2.0 A/B Gold Device Cable
(A Male to B Male) 

1

WATCHDOGSW

WatchDog Service Monitoring / Reboot Software 

1

More information, including related products, owner's manuals, and additional technical specifications, can be found online at 

www.tripplite.com/en/products/model.cfm?txtModelID=2700

Copyright © 2013 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous

improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.

Summary of Contents for SmartPro SMARTINT2200VS

Page 1: ...offers option for instantaneous power off of UPS and connected equipment in the case of fire or emergency Multi function audible alarms and set of 5 front panel LEDs offer at a glance notification of UPS and line power status Network grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges and line noise Attractive gray color scheme Package...

Page 2: ...ltage Frequency compatibility 50 60 Hz Output voltage regulation line mode 19 8 Output voltage regulation Battery mode 5 Built in UPS output receptacles 8 C13 outlet s 1 C19 outlet s Included output power cables Includes 3 C13 to C14 output power cables Built in controllable switched load banks Three switchable two outlet C13 load banks Output circuit breaker 10A x2 each breaker protects 4 C13 out...

Page 3: ...tween 151 and 176 are boosted by 30 LEDS ALARMS SWITCHES LED Indicators 5 LEDs indicate line power battery power overload voltage regulation and battery low replace status Alarms Audible alarm indicates power failure overload and low battery conditions Alarm cancel operation Power fail alarm can be silenced using alarm cancel switch once silenced alarm will re sound to indicate low battery status ...

Page 4: ...le Noise Audible Noise 47dBA At Front Side 1 Meter COMMUNICATIONS Communications interface USB DB9 Serial Contact closure Network monitoring port description Supports detailed monitoring of UPS and site power conditions 2 USB ports 1 DB9 serial and 1 DB9 contact closure port 4 total PowerAlert software Included Communications cable 2 USB and 2 DB9 cables included WatchDog compatibility Supports Wa...

Page 5: ...tors temperature humidity and contact closure inputs Requires SNMPWEBCARD or switched PDU 1 PDU12IEC Basic PDU Power Distribution Unit Safe reliable power distribution for critical networking equipment 1 P004 006 6 ft 18AWG Power cord IEC 320 C14 to IEC 320 C13 1 SNMPWEBCARD For remote monitoring and control via SNMP Web or Telnet 1 U022 010 10 ft USB2 0 A B Gold Device Cable A Male to B Male 1 WA...