Model #: SU10000RT3UG

SmartOnline 10kVA On-Line Double-Conversion UPS, 6U Rack/Tower, 200-240V C19 outlets

 

Highlights

10kVA / 10,000VA / 9000W on-line double-conversion UPS; 0.9 power factor

200/208/220/230/240V 50/60Hz output with economy mode option

6U Rack/Tower compatible; Hot-swappable power and battery modules

USB, RS232 & EPO ports; support for SNMP/WEB and contact-closure card

options

Front panel LEDs with detailed LCD monitoring and control screen

Expandable runtime with optional external battery packs

Hardwire input (3 wire); C19 outlets

Description

Tripp Lite SU10000RT3UG 10,000VA / 10kVA / 9000 watt online, double-conversion UPS system offers complete power protection for critical

network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking

applications. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included

detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected

equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking

applications in data centers, computer rooms, network closets and rugged industrial locations.

Package Includes

SU10000RT3UPM 3U UPS power module

BP240V10RT3U external battery pack

SUPDMB710IEC Detachable PDU with manual bypass switch

Four post compatible rack rail kit (2 sets)

Tower stands for upright tower configuration

PowerAlert software, complete data cabling and user manual

Features

Tripp Lite SU10000RT3UG 10kVA / 10,000VA / 9000 watt on-line, double-conversion UPS system in 6U total rack/tower configuration (3U

UPS power module and 3U external battery pack)

Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no interruption in output power to

connected networking equipment

Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions

Hardwire input; 6 C19 outlets

Maximum installed rack depth of only 32.5 in. / 82.6cm

Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions

and line noise

Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with

enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS

types

Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low 100V and

Summary of Contents for SU10000RT3UG

Page 1: ...s make this UPS ideal for advanced networking applications in data centers computer rooms network closets and rugged industrial locations Package Includes SU10000RT3UPM 3U UPS power module BP240V10RT3U external battery pack SUPDMB710IEC Detachable PDU with manual bypass switch Four post compatible rack rail kit 2 sets Tower stands for upright tower configuration PowerAlert software complete data c...

Page 2: ...nal RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification requires removal of USB interface module Supports Emergency Power Off EPO via built in interface Included rail kit supports 6U 19 inch rackmount installation in 4 post racks Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks Front panel LEDs and LCD readout with sc...

Page 3: ...escription 3 wire single phase input L1 L2 G BATTERY Full load runtime minutes 4 3 min 9000w Half load runtime minutes 12 5 min 4500w Expandable battery runtime Supports extended runtime with optional external battery packs External battery pack compatibility BP240V10RT3U BP240V557C 1PH BP240V787C 1PH BP240V1037C 1PH BP240V1407C 1PH DC system voltage VDC 240 Battery recharge rate included batterie...

Page 4: ...ypass switch to enable hot swap UPS power module replacement SURGE NOISE SUPPRESSION UPS AC suppression response time Instantaneous EMI RFI AC noise suppression Yes PHYSICAL Installation form factors supported with included accessories Tower Included mounting accessory description 2 sets of adjustable 4 post rack rails included 2 9USTAND tower kit included Installation form factors supported with ...

Page 5: ...imensions height x width x depth cm 101 x 80 x 58 4 Shipping weight lbs 331 Shipping weight kg 150 3 UPS housing material Steel Cooling method Fan ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius Storage Temperature Range 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 0 to 95 non condensing AC mode BTU hr full load 3415 AC econo...

Page 6: ...ge variation of 10 Double conversion mode is automatically restored as mains voltage varies beyond 10 with less than 1 millisecond transfer time between modes High availability UPS features Automatic inverter bypass Manual bypass switch Detachable hot swap PDU Hot swappable UPS power module Hot swappable batteries Green high efficiency features High efficiency economy mode operation Schedulable da...

Page 7: ...tery Pack Components 1 SNMP Accessories ENVIROSENSE Monitors temperature humidity and contact closure inputs Requires SNMPWEBCARD or switched PDU 1 SNMP Accessories SNMPWEBCARD For remote monitoring and control via SNMP Web or Telnet 1 SNMP Accessories SRSWITCH Magnetic Door Switch Kit for front and rear doors requires ENVIROSENSE 1 Start Up Warranty Services WEXT3 SU10K 3 Year Extended Warranty F...