background image

UPS Certifications

Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)

WARRANTY

Product Warranty
Period (Worldwide)

2-year limited warranty

Connected
Equipment Insurance
(U.S., Canada &
Puerto Rico)

$250,000 

Ultimate Lifetime Insurance

Related Items

Optional Products

Related Model

Description

Qty.

ENVIROSENSE

Monitors temperature, humidity and contact-closure inputs. (Requires UPS with
SNMPWEBCARD, monitored PDU or switched PDU.) 

1

SRSWITCH

Magnetic Door Switch Kit for front and rear doors; requires ENVIROSENSE 

1

BP48V24-2U

External Battery Pack for UPS System 

1

BP48V60RT-3U

External Battery Pack and Cable. 3U, Expandable, Blue 2-Point Connector 

1

WEXT3-2200-3000

3-Year Extended Warranty - For Smart Line-Interactive and Online Tower or Rack
models, 2200-3000VA 

1

WEXT5-2200-3000

5-Year Extended Warranty - For Smart Line-Interactive and Online Tower or Rack
models, 2200-3000VA or less 

1

2POSTRMKITWM

Enables 2-Post Rackmount or Wallmount Installation of Select Rackmount UPS Systems 

1

2-9USTAND

Enables Tower Placement of Rackmount UPS Systems 

1

PDUB20

Single-Phase Hot-Swap PDU, 20A 120V, 2U Horizontal Rackmount, 4 NEMA 5-15R & 4
NEMA 5-15/20R outlets, 2 NEMA 5-20P input plugs 

1

PDU1220

Single-Phase Basic PDU, 20A 120V, 1U Horizontal Rackmount, 13 NEMA 5-15/20R
outlets, NEMA 5-20P input plug 

1

PDUV20

Single-Phase Basic PDU, 20A 120V, 0U Vertical Rackmount, 14 NEMA 5-15/20R outlets,
NEMA L5-20P input with 5-20P adapter 

1

PDUMV20

Single-Phase Metered PDU, 20A 120V, 0U Vertical Rackmount, 28 NEMA 5-15/20R
outlets, NEMA L5-20P input with 5-20P adapter 

1

PDUMH20AT

Single-Phase Auto Transfer Switch / Metered PDU, 20A 120V, 1U Horizontal
Rackmount, 16 5-15/20R outlets, 2 L5-20P / 5-20P adapters 

1

PDUMNH20

Single-Phase Monitored PDU, 20A 120V, 1U Horizontal Rackmount, 8 NEMA 5-15/20R
outlets, NEMA L5-20P input with 5-20P adapter 

1

PDUMNV20

Single-Phase Monitored PDU, 20A 120V, 70 in. 0U Vertical Rackmount, 24 NEMA
5-15/20R outlets, NEMA L5-20P input with 5-20P adapter 

1

PDUMH20ATNET

Single-Phase Auto Transfer Switch / Switched PDU 20A 120V, 1U Horizontal
Rackmount, 16 5-15/20R outlets, 2 L5-20P / 5-20P inputs 

1

PDUMV20NET

Single-Phase Switched PDU, 20A 120V, 0U Vertical Rackmount, 24 NEMA 5-15/20R
outlets, NEMA L5-20P input with 5-20P adapter 

1

More information, including related products, owner's manuals, and additional technical specifications, can be found online at 

www.tripplite.com/en/products/model.cfm?txtModelID=5685

Copyright © 2013 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous

improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.

Summary of Contents for SU2200RTXL2UN

Page 1: ...liant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Includes PowerAlert monitoring software and complete cabling Emergency Power Off EPO interface LED display reports UPS operating mode line power availability battery mode operation inverter operation and output power availability Audible alarm with push button momentary alarm c...

Page 2: ...ower factor 0 7 Crest Factor 3 1 Nominal Output Voltage s Supported 110V 120V Nominal Voltage details 120V default Frequency compatibility 50 60 Hz Frequency compatibility details Output frequency matches input nominal on startup defaults to 60 Hz on cold start Output voltage regulation line mode 2 Output voltage regulation Economy line mode 10 Output voltage regulation Battery mode 2 Built in UPS...

Page 3: ...ent description Hot swappable user replaceable sealed flame retardant non spillable batteries VOLTAGE REGULATION Voltage regulation description Online double conversion power conditioning Overvoltage correction 2 output voltage regulation during overvoltages to 150 Undervoltage correction 2 output voltage regulation during undervoltages to 80 Severe undervoltage correction 2 output voltage regulat...

Page 4: ...height x width x depth inches 3 5 x 17 5 x 19 UPS Power Module dimensions in primary form factor height x width x depth cm 8 9 x 44 4 x 48 3 Installed whole system dimensions in secondary form factor height x width x depth cm 44 4 x 8 9 x 48 3 Rack Height 2U Secondary form factor Tower requires 2 9USTAND Installed whole system dimensions in secondary form factor height x width x depth inches 17 5 ...

Page 5: ...PWEBCARD interface card Supports detailed monitoring of UPS and site power conditions PowerAlert software Included Communications cable USB and DB9 cabling included WatchDog compatibility Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer time No transfer time 0 ms in online double conversion mode Low voltage transfer to battery ...

Page 6: ...120V 1U Horizontal Rackmount 13 NEMA 5 15 20R outlets NEMA 5 20P input plug 1 PDUV20 Single Phase Basic PDU 20A 120V 0U Vertical Rackmount 14 NEMA 5 15 20R outlets NEMA L5 20P input with 5 20P adapter 1 PDUMV20 Single Phase Metered PDU 20A 120V 0U Vertical Rackmount 28 NEMA 5 15 20R outlets NEMA L5 20P input with 5 20P adapter 1 PDUMH20AT Single Phase Auto Transfer Switch Metered PDU 20A 120V 1U H...

Reviews: