3

Cable Tester Unit

1

  Power Button

 – When off, 

press this button to turn 

the unit on. When on, press 
this button to toggle the 

Auto-Off feature on/off, or 
hold it down to turn off the 

unit.

2

  Power Meter / Light 

Source Button ( )

 – Press 

this button to toggle the 
LCD screen between the 
Power Meter and Light 

Source screens.

3

  Reference Button ( )

 –  

When testing for power 
loss between an external 
light source and the 
power meter, hold this 
button down to save the 
current power loss value. 
When saved, this value 
will appear in the upper-
right corner of the LCD 
screen. Once power loss 
data is saved, pressing 
this button will toggle 
between absolute power 
measurement and relative 
power loss measurement.

1

2

6

8

7

9

3

4

5

4

  Power Measurement Button ( )

 – Press this button to toggle 

between the available units of measurement that can be displayed on 
the LCD screen.

10

11

15-11-089-9334DC-EN.indd   3

11/20/2015   2:11:04 PM

Summary of Contents for T020-001-PSF

Page 1: ...your product for quicker service and ultimate peace of mind You could also win an ISOBAR6ULTRA surge protector a 100 value www tripplite com warranty 1111 W 35th Street Chicago IL 60609 USA www trippl...

Page 2: ...in the cable featuring multiple frequency settings for continuous and flashing modes Light Source supports 1310 nm and 1550 nm wavelengths Power Meter supports 850 nm 1300 nm 1310 nm 1490 nm 1550 nm...

Page 3: ...power loss between an external light source and the power meter hold this button down to save the current power loss value When saved this value will appear in the upper right corner of the LCD screen...

Page 4: ...loss measurement 7 USB Micro B Port If the batteries you are using with the tester are rechargeable you can recharge them by connecting this USB Micro B port to the USB port on a computer or USB wall...

Page 5: ...Battery icon showing the remaining battery capacity 5 Power cord icon will display if you are using rechargeable batteries and charging them via the USB Micro B connector on the side of the unit 6 Au...

Page 6: ...should match that of the light source Press the Power Measurement button to cycle through the available units of measurement to display power loss information in To perform a power measurement test be...

Page 7: ...uencies of 0 Hz 270 Hz 1000 Hz and 2000 Hz To initiate a visual fault locator test press and hold down the Wavelength VFL button The red laser will then be activated and sent through the connected cab...

Page 8: ...E POSSIBILITY OF SUCH DAMAGE Specifically TRIPP LITE is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of subst...

Reviews: