background image

7

Light Source Screen

Visual Fault Locator

To access the light source screen, press the 

Power Meter / Light Source

 ( ) 

button on the unit, toggling from the power meter screen to the light source 

screen. The light source screen consists of the wavelength in the center of 

the screen and the frequency in the upper-right corner.
•  Press the 

Wavelength / VFL button

 ( ) to toggle between the available 

wavelengths. The built in light source supports wavelengths of 1310 nm 
and 1550 nm.

•  Press the 

Frequency / OSL

 ( ) button to toggle between the available 

frequencies. The built in light source supports frequencies of 0 Hz, 270 
Hz, 1000 Hz, and 2000 Hz.

To initiate a visual fault locator test, press and hold down the 

Wavelength / 

VFL

 ( ) button. The red laser will then be activated and sent through the 

connected cable. If there are no breaks in the cable, the red laser will 
shine through the connector on the opposite end of the cable. If there is a 
break, the red laser will stop at the location of the break, where you will be 

able to see it shining through the cable jacket. While performing a visual 
fault locator test, you can press the 

Frequency / OSL

 ( ) button to toggle 

between the available frequencies (0 Hz, 1 Hz, 2 Hz) for continuous or 
flashing modes.

CAUTION!
When performing a visual fault locator test, never point the laser 

directly at your eyes.

15-11-089-9334DC-EN.indd   7

11/20/2015   2:11:06 PM

Summary of Contents for T020-001-PSF

Page 1: ...your product for quicker service and ultimate peace of mind You could also win an ISOBAR6ULTRA surge protector a 100 value www tripplite com warranty 1111 W 35th Street Chicago IL 60609 USA www trippl...

Page 2: ...in the cable featuring multiple frequency settings for continuous and flashing modes Light Source supports 1310 nm and 1550 nm wavelengths Power Meter supports 850 nm 1300 nm 1310 nm 1490 nm 1550 nm...

Page 3: ...power loss between an external light source and the power meter hold this button down to save the current power loss value When saved this value will appear in the upper right corner of the LCD screen...

Page 4: ...loss measurement 7 USB Micro B Port If the batteries you are using with the tester are rechargeable you can recharge them by connecting this USB Micro B port to the USB port on a computer or USB wall...

Page 5: ...Battery icon showing the remaining battery capacity 5 Power cord icon will display if you are using rechargeable batteries and charging them via the USB Micro B connector on the side of the unit 6 Au...

Page 6: ...should match that of the light source Press the Power Measurement button to cycle through the available units of measurement to display power loss information in To perform a power measurement test be...

Page 7: ...uencies of 0 Hz 270 Hz 1000 Hz and 2000 Hz To initiate a visual fault locator test press and hold down the Wavelength VFL button The red laser will then be activated and sent through the connected cab...

Page 8: ...E POSSIBILITY OF SUCH DAMAGE Specifically TRIPP LITE is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of subst...

Reviews: